Beni Adi Trisna

Beni Adi Trisna

Auto-generated profile, based on publicly available information

Beni Adi Trisna

Greenhouse Gas Metrology team, Korea Research Institute of Standard and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2023 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
SKSang Woo Kim
Sang Woo Kim
BTBeni Adi Trisna
Beni Adi Trisna
MYMinkyo Yin
Minkyo Yin
JLJeongsik Lim
Jeongsik Lim
TATae Kyu Ahn
Tae Kyu Ahn
JLJeongsoon Lee
Jeongsoon Lee

30 November 2023 in International Journal of Refrigeration
Verified
Journal Article
Open access
SKSang Woo Kim
Sang Woo Kim
MPMiyeon Park
Miyeon Park
BTBeni Adi Trisna
Beni Adi Trisna
JLJeongsoon Lee
Jeongsoon Lee

14 April 2023 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
BTBeni Adi Trisna
Beni Adi Trisna
SPSeungnam Park
Seungnam Park
IPInjun Park
Injun Park
JLJeongsoon Lee
Jeongsoon Lee
JLJeong Sik Lim
Jeong Sik Lim
Absorption cross sections of emerging greenhouse gases (GHGs) were measured to estimate the radiative efficiency using high-resolution Fourier transform infrared spectroscopy (HR-FTIR). For quantitative spectroscopy, the Beer–Lambert parameters of absorber pressure, temperature, and optical path length (OPL) were accurately determined to be traceable to the primary standards. The OPL of the multipass cell mounted on the HR-FTIR spectrometer was spectroscopically calibrated. A ratio of the averaged N2O absorptions was found to be in the range of 2217.4–2219.0 cm−1, with a spectral resolution of 0.026 cm−1, yielding a ratio of OPLs between the multipass cell and reference cell. This cell-to-cell comparison method is free from the uncertainty of the referring line strength, which reduced the calibration uncertainty compared with the direct line-strength referring method. With the OPL-calibrated multipass cell (3.169 ± 0.079 m), the absorption cross sections were measured at low absorber pressures with a spectral resolution of 2 cm−1, integrated at 10 cm−1 intervals, and multiplied by the new narrow band model to yield the radiative efficiencies. The radiative efficiency values of CF4, SF6, and NF3 were evaluated to be 0.085 ± 0.002, 0.573 ± 0.016, and 0.195 ± 0.008 W m−2 ppb−1, respectively, which are consistent with previously reported values. For the emerging GHGs, the radiative efficiency values were determined to be 0.201 ± 0.008 W m−2 ppb−1 for heptafluoroisobutyronitrile (CF3)2CFCN; commercially referred to as Novec-4710), 0.328 ± 0.013 W m−2 ppb−1 for perfluoro methyl vinyl ether (CF3OCFCF2; PMVE), and 0.544 ± 0.022 W m−2 ppb−1 for 1,1,1,2,2-pentafluoro-2-(trifluoromethoxy)ethane (CF3OCF2CF3; PFMEE).

17 April 2015 in Discover Nano
Verified
Journal Article
Open access
PDF file
BTBeni Adi Trisna
Beni Adi Trisna
NNNitas Nakareseisoon
Nitas Nakareseisoon
WEWin Eiwwongcharoen
Win Eiwwongcharoen
SPSomsak Panyakeow
Somsak Panyakeow
SKSongphol Kanjanachuchai
Songphol Kanjanachuchai
Self-running Ga droplets on GaAs (001) surfaces are repeatedly and reliably formed in a molecular beam epitaxial (MBE) chamber despite the lack of real-time imaging capability of a low-energy electron microscope (LEEM) which has so far dominated the syntheses and studies of the running droplets phenomenon. Key to repeatability is the observation and registration of an appropriate reference point upon which subsequent sublimation conditions are based. The reference point is established using reflection high-energy electron diffraction (RHEED), not the noncongruent temperature used in LEEM where temperature discrepancies up to 25°C against MBE is measured. Our approach removes instrumental barriers to the observation and control of this complex dynamical system and may extend the usefulness of many droplet-related processes.


1 August 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
BTBeni Adi Trisna
Beni Adi Trisna
SUSuherlan
Suherlan
HWHidayat Wiriadinata
Hidayat Wiriadinata
MFMelati Azizka Fajria
Melati Azizka Fajria
IRIip Ahmad Rifa’i
Iip Ahmad Rifa’i
GZGhufron Zaid
Ghufron Zaid
The thermoelectric inhomogeneity as a function of position along wires is one the significant uncertainty of measurement using thermocouples. Here we report development of an electrical annealing system for thermoelectric inhomogeneity treatment. Two inhomogeneous type-S thermocouples, which had the inhomogeneity greater than 0.04%emf, are successfully recovered using the system. An improvement on thermocouple performance as large as 0.28 °C (at temperature of 1000 °C) can be obtained using the system. This article provides detailed information and may help the reader to obtain a quick grasp about the system.