Navneet Gandhi

Navneet Gandhi

Auto-generated profile, based on publicly available information

Navneet Gandhi

PDPM Indian Institute of Information Technology, Design, and Manufacturing, Jabalpur, India

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2023 in IEEE Sensors Letters
Verified
Journal Article
Closed access
NGNavneet Gandhi
Navneet Gandhi
SRSunil Rathore
Sunil Rathore
RJRajeewa Kumar Jaisawal
Rajeewa Kumar Jaisawal
PKP. N. Kondekar
P. N. Kondekar
SDSayan Dey
Sayan Dey
NBNavjeet Bagga
Navjeet Bagga
FET-based sensors are essential for environmental monitoring, industrial analyte detection, medical diagnosis, etc. This letter unveiled the process variation, self-heating-induced performance barrier, and aging issues of the Junctionless FinFET-based hydrogen (H 2 ) gas sensor. Using Sentaurus TCAD, following gate work function modulation owing to H 2 gas concentration (in ppm), we analyzed: (i) the impact of the self-heating effect (SHE) on sensing characteristics; (ii) the impact of different metal grain sizes on work function variation (WFV); (iii) impact of random-dopant fluctuation (RDF); and (iv) device's end-of-lifetime (EOL) to predict the aging. As proof of concept, the Junctionless device was fabricated and found to sense hydrogen with a response of (23.59±1.2)% for 1.0 ppm of the gas, which agrees with our simulation results. The observed threshold voltage sensitivity is a maximum of ∼124.43% for 1.02 ppm. Thus, the proposed analysis would provide a deeper insight into a FinFET-based H 2 gas sensor from a reliability perspective.

5 February 2024 in Smart Materials and Structures
Verified
Journal Article
Closed access
NGNavneet Gandhi
Navneet Gandhi
RJRajeewa Kumar Jaisawal
Rajeewa Kumar Jaisawal
SRSunil Rathore
Sunil Rathore
PKP N Kondekar
P N Kondekar
NBNavjeet Bagga
Navjeet Bagga
This work demonstrates the reliability-aware analysis of the Junctionless negative capacitance (NC) FinFET employed as a hydrogen (H2) gas sensor. Gate stacking of the ferroelectric (FE) layer induces internal voltage amplification owing to the NC property, thus, improving the sensitivity of the baseline junctionless FinFET. A well-calibrated TCAD model is used to investigate the sensing characteristics of the proposed FinFET-based H2 sensor by employing the palladium (Pd) metallic gate as a sensing element. The mechanism involves the transduction of H2 gas molecules over the metal gate; due to the diffusion process, some atomic hydrogen diffuses into the metal. The H2 gas absorption at the metal surface causes a dipole layer formation at the gate and oxide interface, which changes the metal gate work function. As a result, this change in the work function can be used as a sensing parameter of the proposed gas sensor. Further, the threshold voltage and other electrical characteristics, such as output conductance, transconductance, and drain current are examined for sensitivity analysis for both NC and without NC JL FinFET at different pressure ranges, keeping the temperature constant (i.e. 300 K). The device variation, i.e. Fin thickness, Fin height, doping and thickness of HfO2 ferroelectric layer, etc, on sensor sensitivity has been evaluated through extensive simulation. This paper also presents a detailed investigation of the sensor’s reliability in terms of work function variation, random dopant fluctuation, trap charges, and device aging, i.e. end of a lifetime. At last, the acquired results are compared with earlier reported data, which justifies the profound significance of the proposed junctionless negative capacitance FinFET-based H2 gas sensor.

22 November 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
NGNavneet Gandhi
Navneet Gandhi
SRSunil Rathore
Sunil Rathore
RJRajeewa Kumar Jaisawal
Rajeewa Kumar Jaisawal
PKP. N. Kondekar
P. N. Kondekar
ADAnkit Dixit
Ankit Dixit
NBNavjeet Bagga
Navjeet Bagga
In this study, we proposed a dielectric modulated (DM) Negative Capacitance Junctionless FinFET (JLNC-FinFET) to achieve precise label-free electrical detection of biomolecules, including streptavidin (K=2.1), biotin (K=2.63), APTES (K=3.57), and Keratin (K=8) etc., within the designated cavity region. The proposed approach employs variations in the threshold voltage for which the sensitivity (S VTH ) has a maximum value of 15.2% for Pyridine (K=12), serving as discerning metrics for detecting different neutral and charged biomolecules. The baseline Junctionless FinFET, which is fabricated and characterized, in our previous publication, is opted for this study. Realizing the ferroelectric layer over its baseline counterpart offers a notable I ON /I OFF improvement (~10 4 ) in JLNC FinFET. The reliability concerns of metal gate granularities (MGG) and line edge roughness (LER) have been considered to explore the impact on biomolecule detection, i.e., biosensor sensitivity. The results reveal that larger grain sizes exacerbate work function variability, especially with biomolecules resembled by high-K cavities. Moreover, the LER significantly impacts device parameters, which worsens the detection of biomolecules with high-K and LER amplitudes. Thus, the proposed study is worth exploring to acquire the design guidelines for reliability-aware biosensors.

6 January 2025 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
NGNavneet Gandhi
Navneet Gandhi
PKP N Kondekar
P N Kondekar
Viruses such as SARS-CoV, MERS-CoV, and SARS-CoV-2 have posed serious threats to humanity in recent decades, with the COVID-19 pandemic wreaking havoc on both health and the economy. Early detection of these viruses is crucial for mitigating their effect on the immune system. In this study, we propose a dielectric-modulated biosensor realized using junctionless negative capacitance (NC) FinFET with strained silicon (StrS) integration for label-free electrical detection of neutral and charged biomolecules. The biosensor design integrates StrS within the source/drain (S/D) extension region, characterized by a Gaussian doping profile. The device employs a uniaxial stress of 1.4 GPa applied along the channel direction, which modulates the band structure to enhance carrier mobility. Additionally, a ferroelectric (FE) layer is incorporated in the gate stack, introducing a NC effect. This configuration reduces the OFF current while increasing the ON current, thereby improving the selectivity of the sensor. A ‘T-shaped’ metal support is incorporated, featuring cavities on both sides for the biomolecule’s accommodation. Our investigation focuses on the label-free detection of various biomolecules characterized by their equivalent dielectric constant (K), e.g. Streptavidin (K = 2.1), Biotin (K = 2.63), APTES (K = 3.57), Keratin (K = 8), etc. Discrimination between different biomolecules is achieved by analyzing variations in threshold voltage (V TH), OFF current, and I ON/I OFF ratio as sensing metrics. The limit of detection (LoD) of the proposed sensor was meticulously estimated through a machine learning approach, achieving an impressive sensitivity with a calculated value of 0.47, quantified in terms of the ‘K’ of the biomolecules. A comprehensive analysis also involves the sensitivity and selectivity analysis with different FE thicknesses. Our study found that Pyridine (K = 12) biomolecules have the highest V TH and OFF current sensitivity (189.57% and 85.51%, respectively), as well as the highest V TH and OFF current selectivity over Streptavidin (1.3 and 0.811, respectively) at FE thickness of 1.8 nm. Furthermore, this paper explores the impact of low-frequency noise (i.e. flicker noise) on the noise power spectral density (PSD) of the proposed biosensor in the presence of different biomolecules. Our findings reveal that an increase in the gate coupling capacitance corresponds to the rise in K of biomolecules, leading to a decrease in noise PSD ( S ID / I D 2 ) and a subsequent reduction in noise. Using well-calibrated TCAD models, the acquired results reveal that incorporating StrS leads to a ∼41% increase in the ON current over its baseline case.

29 July 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NGNavneet Gandhi
Navneet Gandhi
PKP. N. Kondekar
P. N. Kondekar
This study presents an artificial neural network (ANN)-assisted optimization framework for the raised source-drain (RSD) dielectric-modulated (DM) junctionless (JL) Negative Capacitance (NC) FinFET biosensor, designed to detect both charged and neutral biomolecules. The biosensor features a “T-shaped” metal support, providing adsorption regions on both sides for enhanced biomolecule detection. To evaluate the ANN model’s performance, Root Mean Square Error (RMSE) and R2-score are analyzed. The network architecture comprises an input, followed by two hidden layers with 32 and 16 neurons, and an output layer with a single neuron. The model achieved a maximum R2-score of 0.9872 and a minimum RMSE of 0.0274 when trained on 90% of the dataset. Its reliability is further ensured through K-fold cross-validation. The training and prediction processes utilize a TCAD-integrated ANN framework, where the dataset is generated by systematically varying key device parameters such as channel length (Lg), channel doping concentration (NCH), fin thickness (TFin), and support work function (SMWF). A total of 1140 device simulations were performed, demonstrating the ANN capability to accurately predict the biosensor’s sensitivity to pyridine biomolecules with high precision.

27 June 2025 in Physica Scripta
Verified
Journal Article
Closed access
NGNavneet Gandhi
Navneet Gandhi
PKP N Kondekar
P N Kondekar
This study presents a comparative machine learning (ML)-assisted optimization framework for a raised source-drain (RSD) dielectric-modulated (DM) junctionless (JL) Negative Capacitance (NC) FinFET biosensor, designed for detecting both charged and neutral biomolecules. The biosensor incorporates a ‘T-shaped’ metal support, providing adsorption regions on both sides to enhance biomolecule detection.Two ML algorithms, Random Forest Regression (RFR) and Artificial Neural Network (ANN), are employed to predict the sensor’s sensitivity with high accuracy. The performance of both models is evaluated using Root Mean Square Error (RMSE) and R2-score, with reliability ensured through K-fold cross-validation. The ANN model, featuring two hidden layers with 32 and 16 neurons, achieves a maximum R2-score of 0.9888 and a minimum RMSE of 0.031. The RFR model also demonstrates strong predictive capability, achieving an R2-score of 0.9815 and an RMSE of 0.0359. The training dataset is generated through 1140 device simulations in a TCAD-integrated ML framework by systematically varying key device parameters, including channel length (Lg), channel doping concentration (NCH), fin thickness (TFin), and support metal work function (SMWF). Furthermore, the limit of detection (LoD) of the proposed biosensor is calculated using the International Union of Pure and Applied Chemistry (IUPAC) definition in conjunction with an ML approach. This comparative analysis provides valuable insights into the strengths and limitations of both models, guiding the selection of an optimal ML approach for biosensor performance prediction.