Merida Rodriguez-Lopez

Merida Rodriguez-Lopez

Auto-generated profile, based on publicly available information

Merida Rodriguez-Lopez

Universidad Icesi, Cali, Valle del Cauca, Colombia

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2016 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
PDF file
MRM. Rodríguez‐López
M. Rodríguez‐López
MCMónica Cruz-Lemini
Mónica Cruz-Lemini
BVB. Valenzuela‐Alcaraz
B. Valenzuela‐Alcaraz
LGL. Garcia‐Otero
L. Garcia‐Otero
MSM. Sitges
M. Sitges
FCFatima Crispi
Fatima Crispi
Objective: To identify different cardiac phenotypes among cases of fetal growth restriction (FGR).Methods: Echocardiography was performed in 126 cases with FGR (birth weight < 10th centile) and 64 appropriate‐for‐gestational‐age (AGA) fetuses. Principal component and cluster analyses were performed to identify different cardiac phenotypes among FGR cases.Results: Three different cardiac phenotypes were identified among the FGR group: globular in 54% of cases, elongated in 29% of cases and hypertrophic in 17% of cases. Those with a globular heart had the lowest median left‐ventricular sphericity index (controls, 1.78 (interquartile range (IQR), 1.62–1.97); FGR elongated, 1.92 (IQR, 1.78–2.09); FGR globular, 1.44 (IQR, 1.36–1.52); FGR hypertrophic, 1.65 (IQR, 1.42–1.77); P = 0.001). FGR cases with an elongated left ventricle had nearly normal cardiac dimensions. FGR cases with a hypertrophic phenotype had the highest median left‐ventricular wall thickness (controls, 1.22 (IQR, 1.10–1.67) mm/kg; FGR elongated, 1.52 (IQR, 1.28–1.86) mm/kg; FGR globular, 1.65 (IQR, 1.39–1.99) mm/kg; FGR hypertrophic, 3.68 (IQR, 3.45–4.71) mm/kg; P = 0.001) and cardiac dimensions. Globular and elongated phenotypes showed a fetoplacental profile of late‐onset FGR, while the hypertrophic phenotype showed signs of early‐onset FGR. The hypertrophic group also had the poorest perinatal results, having the lowest birth‐weight centile, gestational age at delivery and Apgar score and the highest postnatal blood pressure and aorta intima–media thickness.Conclusions: FGR induces at least three different cardiac phenotypes, with early‐onset FGR cases being associated with a hypertrophic response and worse perinatal outcomes. This cardiac phenotypic classification may improve identification of FGR cases with the highest perinatal and long‐term cardiovascular risks. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

1 January 2017 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
SSSebastian Imre Sarvari
Sebastian Imre Sarvari
MRMerida Rodriguez-Lopez
Merida Rodriguez-Lopez
MNMarta Nuñez-Garcia
Marta Nuñez-Garcia
MSMarta Sitges
Marta Sitges
ASAlvaro Sepulveda-Martinez
Alvaro Sepulveda-Martinez
FCFatima Crispi
Fatima Crispi
Background—: Fetal growth restriction (FGR) affects 5% to 10% of newborns and is associated with increased cardiovascular mortality in adulthood. We evaluated whether prenatal cardiovascular changes previously demonstrated in FGR persist into preadolescence. Methods and Results—: A cohort study of 58 FGR (defined as birth weight below 10th centile) and 94 normally grown fetuses identified in utero and followed-up into preadolescence (8–12 years of age) by echocardiography and 3-dimensional shape computational analysis. Compared with controls, FGR preadolescents had a different cardiac shape, with more spherical and smaller hearts. Left ventricular ejection fraction was similar among groups, whereas FGR had decreased longitudinal motion (decreased mitral annular systolic peak velocities: control median, 0.11 m/s [interquartile range, 0.09–0.12] versus FGR median 0.09 m/s [interquartile range, 0.09–0.10]; P <0.01) and impaired relaxation (isovolumic relaxation time: control, 0.21 ms [interquartile range, 0.12–0.35] versus FGR, 0.35 ms [interquartile range, 0.20–0.46]; P =0.04). Global longitudinal strain was decreased (control mean, −22.4% [SD, 1.37] versus FGR mean, −21.5% [SD, 1.16]; P <0.001) compensated by an increased circumferential strain and with a higher prevalence of postsystolic shortening in FGR as compared with controls. These differences persisted after adjustment for parental ethnicity and smoking, prenatal glucocorticoid administration, preeclampsia, gestational age at delivery, days in intensive care unit, sex, age, and body surface area at evaluation. Conclusions—: This study provides evidence that cardiac remodeling induced by FGR persists until preadolescence with findings similar to those reported in their prenatal life and childhood. The findings support the hypothesis of primary cardiac programming in FGR for explaining the association between low birth weight and cardiovascular risk in adulthood.

1 September 2014 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
FCFàtima Crispi
Fàtima Crispi
BBBart Bijnens
Bart Bijnens
ESEduardo Sepulveda-Swatson
Eduardo Sepulveda-Swatson
MCMónica Cruz-Lemini
Mónica Cruz-Lemini
JRJuan Rojas-Benavente
Juan Rojas-Benavente
EGEduard Gratacos
Eduard Gratacos
Background—: Fetal growth restriction (FGR) is associated with global adverse cardiac remodeling in utero and increased cardiovascular mortality in adulthood. Prenatal myocardial deformation has not been evaluated in FGR to date. We aimed to evaluate prenatal cardiac remodeling comprehensively in FGR including myocardial deformation imaging. Methods and Results—: Echocardiography was performed in 37 consecutive FGR (defined as birthweight <10th centile) and 37 normally grown fetuses. A comprehensive fetal echocardiography was performed including tissue Doppler and 2-dimensional–derived strain and strain rate. Postnatal blood pressure measurement at 6 months of age was also performed. FGR cases showed signs of more globular hearts with decreased longitudinal motion (left systolic annular peak velocity: controls mean 6 cm/s [SD 1.2] versus FGR 5.3 [1]) and diastolic dysfunction (isovolumic relaxation time: controls 44 ms [6] versus FGR 52 [9]). Peak strain and strain rate values of the left ventricle were not significantly different; however, a postsystolic shortening in the basal segment of the septal ventricular wall was observed in 57% of the FGR cases and in none of controls ( P <0.001). FGR cases with postsystolic shortening had absence of a hypertrophic response, a poorer perinatal outcome (lower gestational age and birthweight, containing all cases of perinatal mortality [8%]), and higher values of blood pressure. Conclusions—: Myocardial deformation imaging revealed a postsystolic shortening in 57% of FGR, which supports increased pressure overload as a mechanism for cardiovascular programming in FGR. Postsystolic shortening was associated with severity and with higher blood pressure postnatally.

9 October 2023 in International Journal of Gynecology & Obstetrics
Verified
Journal Article
Open access
HVHernán Darío Vargas‐Cardona
Hernán Darío Vargas‐Cardona
MRMérida Rodriguez‐Lopez
Mérida Rodriguez‐Lopez
MAMarcela Arrivillaga
Marcela Arrivillaga
CSCarlos Vergara Sanchez
Carlos Vergara Sanchez
JGJuan P. García‐Cifuentes
Juan P. García‐Cifuentes
AJAndres Jaramillo-Botero
Andres Jaramillo-Botero
Background: The intersection of artificial intelligence (AI) with cancer research is increasing, and many of the advances have focused on the analysis of cancer images.Objectives: To describe and synthesize the literature on the diagnostic accuracy of AI in early imaging diagnosis of cervical cancer following Preferred Reporting Items for Systematic Reviews and Meta‐Analyses Extension for Scoping Reviews (PRISMA‐ScR).Search Strategy: Arksey and O'Malley methodology was used and PubMed, Scopus, and Google Scholar databases were searched using a combination of English and Spanish keywords.Selection Criteria: Identified titles and abstracts were screened to select original reports and cross‐checked for overlap of cases.Data Collection and Analysis: A descriptive summary was organized by the AI algorithm used, total of images analyzed, data source, clinical comparison criteria, and diagnosis performance.Main Results: We identified 32 studies published between 2009 and 2022. The primary sources of images were digital colposcopy, cervicography, and mobile devices. The machine learning/deep learning (DL) algorithms applied in the articles included support vector machine (SVM), random forest classifier, k‐nearest neighbors, multilayer perceptron, C4.5, Naïve Bayes, AdaBoost, XGboots, conditional random fields, Bayes classifier, convolutional neural network (CNN; and variations), ResNet (several versions), YOLO+EfficientNetB0, and visual geometry group (VGG; several versions). SVM and DL methods (CNN, ResNet, VGG) showed the best diagnostic performances, with an accuracy of over 97%.Conclusion: We concluded that the use of AI for cervical cancer screening has increased over the years, and some results (mainly from DL) are very promising. However, further research is necessary to validate these findings.

15 September 2015 in Pediatric Research
Verified
Journal Article
Closed access
MRMerida Rodriguez-Lopez
Merida Rodriguez-Lopez
LOLyda Osorio
Lyda Osorio
RARuthy Acosta-Rojas
Ruthy Acosta-Rojas
JFJosep Figueras
Josep Figueras
MCMónica Cruz-Lemini
Mónica Cruz-Lemini
FCFatima Crispi
Fatima Crispi

22 December 2016 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Closed access
PDF file
Jezid MirandaJezid Miranda
Jezid Miranda
MRM. Rodriguez‐Lopez
M. Rodriguez‐Lopez
STS. Triunfo
S. Triunfo
MSM. Sairanen
M. Sairanen
HKH. Kouru
H. Kouru
EGE. Gratacós
E. Gratacós