Objective: The aim of this study was to review the selection criteria of resin cements for different types of partial coverage restorations (PCRs) and investigate if the type of restorations or restorative materials affect the type of selected resin cement.Materials and Methods: An electronic search (1991–2023) was performed in PubMed, Medline, Scopus, and Google Scholar databases by combinations of related keywords.Results: A total of 68 articles were included to review the selection criteria based on the advantages, disadvantages, indications, and performance of resin cements for different types of PCRs.Conclusions: The survival and success of PCRs are largely affected by appropriate cement selection. Self‐curing and dual‐curing resin cements have been recommended for the cementation of metallic PCRs. The PCRs fabricated from thin, translucent, and low‐strength ceramics could be adhesively bonded by light‐cure conventional resin cements. Self‐etching and self‐adhesive cements, especially dual‐cure types, are not generally indicated for laminate veneers.
7 December 2021 in International Journal of Dentistry
Purpose. This study aimed to compare marginal and internal adaptation in endocrowns made from translucent zirconia and zirconium lithium silicate using CAD-CAM technology. Materials and Methods. Twenty-eight freshly extracted upper molars were mounted in acrylic resin and underwent root canal therapy and endocrown preparation up to 2 mm above the cementoenamel junction. Endocrowns were CAD-CAM milled from zirconium lithium silicate (ZLS) and translucent zirconia (Zr). Internal and marginal adaptation was assessed by the replica technique before cementation. Marginal adaptation was evaluated by a stereomicroscope (×32) before and after cementation and also after thermomechanical aging. Results. The ZLS group showed significantly higher internal adaptation compared to the Zr group ( = 0.028), while the marginal adaptation differences, at different times with different methods, were not statistically significant ( > 0.05). Axiomarginal angle had the highest and axiopulpal angle showed the lowest adaptation in both groups. The cementation process and thermomechanical aging increased the marginal gap in both groups significantly ( < 0.001). The marginal gap assessed by the replica technique before cementation was 7.11 µm higher than direct view under a stereomicroscope with intraclass correlation coefficient of 0.797. Conclusion. Zirconia seems to be an acceptable material for endocrown with comparable internal and marginal adaptation to ZLS. Cementation and thermomechanical aging had significantly negative effects on marginal gap. The marginal gap assessed by the replica technique was higher than direct view under the stereomicroscope technique.
Limited studies assess clinical key factors in the success of digitally fabricated complete dentures between additive and subtractive methods. This study aimed to compare 2 determinants of clinical success-retention and patient satisfaction- in complete dentures fabricated using additive and subtractive approaches. PubMed, Scopus, Web of Science, Embase, Cochrane Library, and Google Scholar were searched up to August 2024. Records were screened by title, abstract, and full text against the eligibility criteria. The standardized mean difference (SMD) was calculated using the data extracted from each included study. A random effects model pooled the effect sizes, and heterogeneity was assessed with Cochran's Q test, I-squared, and Tau-squared indices; publication bias was evaluated using Begg's funnel plot and the Egger test, while sensitivity analyses checked result robustness. The risk of bias was assessed using the Cochrane RoB 2 and ROBINS-I tools. Of the initial 1098 records, a total of 4 articles were deemed eligible. Although mean denture retention was higher in the additive compared to the subtractive method, the difference was not statistically significant (SMD = 0.165 N, 95% CI = [-0.176, 0.506], P = .343, I² = 58.72%). Similarly, mean satisfaction was lower in the additive compared to the subtractive method, but this difference was not statistically significant (SMD = -0.595, 95% CI = [-1.579, 0.389], P = .236, I² = 85.94%). Considering the high heterogeneity and the small number of studies, it can be cautiously concluded that there is no significant difference between complete dentures fabricated by 3D printing and milling approaches.
1 November 2014 in The International Journal of Prosthodontics
Kianoosh Torabi, DDS, MScD/Sasan Rasaei Pour, DDS, MScD/Ahmad Hassan Ahangari, DDS, MScD/Safoura Ghodsi, DDS, MScD: Evaluation of mandibular movements is necessary to form the occlusal anatomical contour, analyze the temporomandibular joint status, and evaluate the patient?s occlusion. This clinical study was conducted to compare the mandibular recording device Cadiax Compact II with routine intraoral records for measuring condylar inclinations. The results showed that the differences between Cadiax and intraoral records were statistically significant for all measurements. Cadiax measurements had a stronger correlation with silicone records. The quantities of recorded Bennett angles were lower and the values of sagittal condylar inclination were higher with Cadiax than with routine intraoral records. Int J Prosthodont 2014;27:541?543. doi: 10.11607/ijp.3852
1 August 2012 in The Journal of Contemporary Dental Practice
Background: Mandibular movement analysis is a critical step in making the functional occlusal morphology and improving the diagnosis and treatment of temporomandibular joint disorders (TMDs). Cadiax Compact® is an electronic condylograph that claims to record the horizontal condylar inclination (HCI), Bennett angle (BA) and relative shape of the articular eminence. This study aims at assessing the accuracy of Cadiax Compact® II in its claimed abilities.Materials and methods: The electronic condylograph (Cadiax Compact®II) was fitted on the fully adjustable articulator (gamma dental reference- SL). After setting of HCI and BA on the arbitrary degrees, eccentric movements were produced manually on the articulator. The Cadiax recorded these preadjusted angles and the accuracy of its recordings was assessed by comparison of the results with the preadjusted HCI, BA and color inserts as references.Results: The majority of the comparisons showed statistically significant differences between articulator settings and Cadiax recordings. However, the maximum difference was about 2.5° which seems acceptable for clinical practice.Conclusion: The obtained results showed that Cadiax Compact is an accurate and reliable instrument for diagnostic purposes, yielding reproducible measurements. Despite this, Cadiax is a technically sensitive device that can preclude its routine usage.How to cite this article: Ahangari AH, Torabi K, Pour SR, Ghodsi S. Evaluation of the Cadiax Compact® II Accuracy in Recording Preadjusted Condylar Inclinations on Fully Adjustable Articulator. J Contemp Dent Pract 2012;13(4):504-508.
1 June 2017 in The Journal of Contemporary Dental Practice
Aim: Surface treatment is necessarily required for bonding of zirconia to the veneering porcelain and luting cements. Sandblasting is the most common and probably the most efficient surface treatment method. Sandblasting roughens the surface and may affect the flexural strength of zirconia. Different sandblasting protocols may yield variable results. This study sought to assess the effect of sandblasting angle and distance on the biaxial flexural strength of zirconia-based ceramics.Materials and methods: Thisin vitroexperimental study was conducted on 50 zirconia discs measuring 1.2 ± 0.2 mm in thickness and 15 ± 0.2 mm in diameter, which were randomly divided into five groups (n = 10) of one control and four experimental groups subjected to sandblasting with 110 µm aluminum oxide particles under 2 bar pressure for 10 seconds at 15 and 25 mm distances and 45 and 90° angles (between the nozzle head and zirconia surface). Surface roughness was measured by a roughness tester and samples were subjected to thermocycling followed by biaxial flexural strength testing according to ISO6872. The data were analyzed using one-way analysis of variance (p < 0.05).Results: No statistically significant difference was noted in the mean biaxial flexural strength of the five groups (p = 0.40). Different sandblasting protocols yielded significantly different surface roughness values (p < 0.001). The highest and the lowest mean surface roughness belonged to 15 mm/90° (0.51 µm) and control (0.001 µm) groups respectively.Conclusion: Change in sandblasting angle and distance had no significant effect on the biaxial flexural strength of zirconiabased ceramic, but surface roughness was significantly different in the study groups.Clinical significances: Regardless of sandblasting angle, increasing distance to 25 mm significantly decreases surface roughness that may negatively affect zirconia bond strength.How to cite this article: Zeighami S, Gheidari A, Mahgoli H, Rohanian A, Ghodsi S. Effect of Sandblasting Angle and Distance on Biaxial Flexural Strength of Zirconia-based Ceramics. J Contemp Dent Pract 2017;18(6):443-447.