Judith Tettenborn

Judith Tettenborn

Auto-generated profile, based on publicly available information

Judith Tettenborn

Copernicus Institute for Sustainable Development, Utrecht University

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2025 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
JTJudith Tettenborn
Judith Tettenborn
DZDaniel Zavala-Araiza
Daniel Zavala-Araiza
DSDaan Stroeken
Daan Stroeken
HMHossein Maazallahi
Hossein Maazallahi
CVCarina van der Veen
Carina van der Veen
TRThomas Röckmann
Thomas Röckmann
Mobile real-time measurements of ambient methane provide a fast and effective method to identify and quantify methane leaks from local gas distribution systems in urban areas. The objectives of these methodologies are to (i) identify leak locations for repair and (ii) construct measurement-based emission rate estimates, which can improve emissions reporting and contribute to monitoring emission changes over time. Currently, the most common method for emission quantification uses the maximum methane enhancement detected while crossing a methane plume. However, the recorded maximum depends on instrument characteristics, such as measurement cell size, pump speed, and measurement frequency. Consequently, the current approach can only be used by instruments with similar characteristics. We suggest that the integrated spatial peak area is a more suitable quantity that can eliminate the bias between different instruments. Based on controlled release experiments conducted with various devices in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Indeed, when different analysers were measuring in the same vehicle and from the same air inlet, the integrated spatial peak area was found to be a more robust metric across different methane gas analyser devices than the maximum methane enhancement. A statistical function based on integrated spatial peak area is proposed for more consistent emission estimations when using different instruments. On top of this systematic relation between actual emission rate and recorded spatial peak area, large variations in methane spatial peak area were observed for the multiple transects across the same release point, in line with previous experiments. This variability is the main contributor to uncertainty in efforts to use mobile measurements to prioritize leak repair. We show that repeated transects can reduce this uncertainty and improve the categorization into different leak categories. We recommend a minimum of three and an optimal range of five–seven plume transects for effective emission quantification to prioritize repair actions.

17 January 2025 in EGUsphere
Verified
Preprint
Open access
PDF file
JTJudith Tettenborn
Judith Tettenborn
DZDaniel Zavala-Araiza
Daniel Zavala-Araiza
DSDaan Stroeken
Daan Stroeken
HMHossein Maazallahi
Hossein Maazallahi
CVCarina van der Veen
Carina van der Veen
TRThomas Röckmann
Thomas Röckmann
Mobile real-time measurements of ambient methane provide a fast and effective method to identify and quantify methane leaks from local gas distribution systems in urban areas. The objectives of these methodologies are to i) identify leak locations for repair and ii) construct measurement-based emission rate estimates, which can improve emissions reporting and contribute to monitoring emission changes over time. Currently, the most common method for emission quantification uses the maximum methane enhancement detected while crossing a methane plume. However, the recorded maximum depends on instrument characteristics, such as measurement cell size, pump speed and measurement frequency. Consequently, the current approach can only be used by instruments with similar characteristics. We suggest that the integrated spatial peak area is a more suitable quantity that can eliminate the bias between different instruments. Based on controlled release experiments conducted in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Indeed, the integrated spatial peak area was found to be a more robust metric across different methane gas analyzer devices than the maximum methane enhancement. A statistical function based on integrated spatial peak area is proposed for more consistent emission estimations when using different instruments. On top of this systematic relation between actual emission rate and recorded spatial peak area, large variations in methane spatial peak area were observed for the multiple transects across the same release point, in line with previous experiments. This variability is the main contributor of uncertainty in efforts to use mobile measurements to prioritize leak repair. We show that repeated transects can reduce this uncertainty and improve the categorization into different leak categories. We recommend a minimum of three and an optimal range of 5-7 plume transects for effective emission quantification to prioritize repair actions.

10 June 2026 in EGUsphere
Verified
Preprint
Open access
PDF file
AAAnke Frederike Arp
Anke Frederike Arp
LKLuja von Köckritz
Luja von Köckritz
JTJudith Tettenborn
Judith Tettenborn
MZMarianne Zanon Zotin
Marianne Zanon Zotin
MEMartijn van Engelenburg
Martijn van Engelenburg
DVDetlef P. van Vuuren
Detlef P. van Vuuren
We present the IMAGE-materials model, a stock-driven dynamic material flow analysis model, part of the IMAGE integrated assessment model (IAM) framework. y combining modelling principles from the IAM and Industrial Ecology (IE) communities, the model quantifies material inflows, stocks, and outflows affected by climate and resource policy scenarios. IMAGE-materials is a recursive yearly simulation model that projects global material demand until 2100 for 26 world regions on a sectoral level for a wide variety of bulk and critical materials. The model includes buildings, vehicles, electricity, rail & road infrastructure, and a residual sector capturing the remaining demand, including different types and modes (e.g., housing types and transport modes). It is written using a modular, object-oriented Python architecture, enabling the easy addition of new sectors and data. Key assumptions include product lifetimes, material intensities, and technology mixes. The model is driven by service demand scenarios produced by the IMAGE framework, based on socio-economic and climate policy assumptions. IMAGE-materials can flexibly simulate the adoption of numerous circular economy measures, such as service demand reductions, lifetime extension, lightweighting, and recycling. Therefore, IMAGE-materials enables scientists and policymakers to explore mitigation pathways with a detailed additional dimension of material flows. It can thus assess the synergies and trade-offs between climate and circularity policies by explicitly accounting for their material implications. As such, IMAGE-materials integrates the fields of IAMs and IE, building on the strengths of each.

20 January 2025
Verified
Conference Paper
Open access
JTJudith Tettenborn
Judith Tettenborn
DZDaniel Zavala-Araiza
Daniel Zavala-Araiza
DSDaan Stroeken
Daan Stroeken
HMHossein Maazallahi
Hossein Maazallahi
AHArjan Hensen
Arjan Hensen
TRThomas Röckmann
Thomas Röckmann
Efficient and cost-effective mitigation of methane emissions from local gas distribution systems requires full characterization of leaks across an urban region. Mobile real-time measurements of ambient CH4 provide a fast and effective approach to identify and quantify methane leaks. The objective of such methodologies is to relate emission rates to parameters obtained during mobile measurements. These parameters encompass the maximum methane enhancement detected while crossing a methane plume and the integrated area of the associated peak. The maximum enhancement is currently used for emission quantification in mobile measurements, but was suggested to exhibit inconsistency among various measurement devices. Based on controlled release experiments conducted in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Integrated plume area was found to be a more robust metric across different methane gas analyzer devices than the maximum methane enhancement. A statistical function based on integrated plume area is proposed for more consistent emission estimations when using different instruments. Nevertheless, large temporal variations in CH4 concentration enhancements were observed for the same release rate in line with previous experiments. Evaluation of repeated measurements to address this uncertainty and enable differentiation among various leak sizes was included. This study recommends a minimum of three repeated measurements and an optimal range of 5-7 plume transects for effective emission quantification to prioritize repair actions.

10 June 2026
Verified
Other
Open access
AAAnke Frederike Arp
Anke Frederike Arp
LKLuja von Köckritz
Luja von Köckritz
JTJudith Tettenborn
Judith Tettenborn
MZMarianne Zanon Zotin
Marianne Zanon Zotin
MEMartijn van Engelenburg
Martijn van Engelenburg
DVDetlef P. van Vuuren
Detlef P. van Vuuren

31 March 2025
Verified
Other
Open access
PDF file
JTJudith Tettenborn
Judith Tettenborn
DZDaniel Zavala-Araiza
Daniel Zavala-Araiza
DSDaan Stroeken
Daan Stroeken
HMHossein Maazallahi
Hossein Maazallahi
CVCarina van der Veen
Carina van der Veen
TRThomas Röckmann
Thomas Röckmann
Mobile real-time measurements of ambient methane provide a fast and effective method to identify and quantify methane leaks from local gas distribution systems in urban areas. The objectives of these methodologies are to i) identify leak locations for repair and ii) construct measurement-based emission rate estimates, which can improve emissions reporting and contribute to monitoring emission changes over time. Currently, the most common method for emission quantification uses the maximum methane enhancement detected while crossing a methane plume. However, the recorded maximum depends on instrument characteristics, such as measurement cell size, pump speed and measurement frequency. Consequently, the current approach can only be used by instruments with similar characteristics. We suggest that the integrated spatial peak area is a more suitable quantity that can eliminate the bias between different instruments. Based on controlled release experiments conducted in four cities (London, Toronto, Rotterdam, and Utrecht), emission estimation methodologies were evaluated. Indeed, the integrated spatial peak area was found to be a more robust metric across different methane gas analyzer devices than the maximum methane enhancement. A statistical function based on integrated spatial peak area is proposed for more consistent emission estimations when using different instruments. On top of this systematic relation between actual emission rate and recorded spatial peak area, large variations in methane spatial peak area were observed for the multiple transects across the same release point, in line with previous experiments. This variability is the main contributor of uncertainty in efforts to use mobile measurements to prioritize leak repair. We show that repeated transects can reduce this uncertainty and improve the categorization into different leak categories. We recommend a minimum of three and an optimal range of 5-7 plume transects for effective emission quantification to prioritize repair actions.