31 October 2024 in New Materials and Technologies in Metallurgy and Mechanical Engineering
Purpose. Increasing the resolution and magnification of the optical microscope to expand the possibilities of observation and research in various fields of science and technology. Research methods. Theoretical, experimental. Results. A comparative analysis of the human eye as an optical system and the optical system of a microscope was carried out. It was found that these systems have a similar nature, namely, a separate image of two closely located objects. If we consider the human eye as a light-sensitive matrix, then to determine the resolution of the eye, it is necessary to use the ratio of the average value of the number of light-sensitive elements (rods and cones) that fall on the retina to the area of the retina itself (for the human eye, it is 0.1...0.2 mm). For an optical microscope, it is necessary to separate the concepts of “resolution” and “magnification”. We also mentioned the physical basis of the resolution of optical microscopes. It was shown that for a dry lens the resolution limit for λ = 555 nm is 0.3 μm. One of the ways to increase the resolution is the use of immersion fluids. However, in certain studies its use is inappropriate or impossible. If instead of conventional illuminators (maximum intensity at λ = 555 nm) you use ultraviolet ones (λ = 380…410 nm), then the resolution can be increased several times, and the increase is up to 2000. The disadvantage of using UV illuminators is that it is necessary to use a light filter with direct observation or a monitor with an indirect method to avoid negative effects on the observer’s vision. Scientific novelty. The increased resolution and magnification of the optical microscope when using coherent light sources instead of immersion fluids provides more detailed scientific information and facilitates its processing. Practical value. Using the results of our research allows you to get a more informative image when using coherent light sources.
30 October 2023 in SWorld-Ger Conference proceedings
This paper examines the main stages of graphene research and its structure. The methods of obtaining the material and its properties are identified. The proposed material has been reviewed in the literature for compliance with the criteria necessary for s
1 January 2021 in Electrical Engineering & Electromechanics
Purpose. Investigation of the influence of higher harmonics of current on current distribution, voltage and power losses in the supply systems of crane trolleys and development of a calculation method for practical use. Methodology. The analytical method and the results of the modeling method were used for research. Results. Analytical relationships have been obtained that make it possible to determine the current distribution, voltage and power losses in the systems of induction feeding of crane trolleys, taking into account the composition and amplitude of the higher harmonics of the current. Originality. For the first time, analytical dependences are obtained that take into account the effect of changing the trolley parameters on the frequency in the feed systems. Numerical values have been determined for the most commonly used induction feed systems for cranes. It is shown that with an increase in the cross-section of the feed bar there is a decrease in the main, and especially additional, losses. Practical value. Theoretical relationships have been obtained that can be used to calculate the optimization of induction feed systems in the presence of higher harmonic currents arising in power systems during operation of crane semiconductor controlled electric drives. References 13, tables 4, figures 6.
30 September 2026 in New Materials and Technologies in Metallurgy and Mechanical Engineering
Purpose. Development, technical justification and experimental verification of an LED lighting element to replace an incandescent lamp in a MIM-8 metallographic microscope, as well as to assess the possibility of using coherent and partially coherent LED sources in microscopy. Research methods. Theoretical analysis of scientific and technical literature, calculation methods for determining electrical and lighting parameters, design of the lighting module, experimental tests in conditions close to real operation, as well as comparative analysis of microimages obtained with different lighting sources. Results. An LED lighting unit with active heat dissipation and PWM brightness control has been developed, which is compatible with the design of the MIM-8 microscope without changing its optical scheme. It was established that the modernized system provides stable lighting, better uniformity of the field of view, increased contrast of microimages and a significant reduction in energy consumption compared to a standard incandescent lamp. It was shown that the LED source provides a stable light flux immediately after switching on and is suitable for long-term operation without noticeable degradation of characteristics. Scientific novelty. It consists in the engineering justification and practical implementation of an LED lighting solution for the modernization of the MIM-8 microscope, taking into account its design, optical and thermal features. Additionally, the feasibility of using coherent and partially coherent LED sources as a promising direction for increasing the functionality of microscopic systems is substantiated. Practical value. The proposed solution makes it possible to restore the operability of an outdated metallographic microscope, reduce energy consumption, increase the reliability of the lighting system, improve the quality of microimages and extend the service life of laboratory equipment without significant capital costs.