Diego F. Echeverry

Diego F. Echeverry

Auto-generated profile, based on publicly available information

Diego F. Echeverry

Eck Institute for Global Health, University of Notre Dame, Notre Dame, IN, 46556, USA.

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2017 in Malaria Journal
Verified
Journal Article
Open access
PDF file
DEDiego F. Echeverry
Diego F. Echeverry
NDNicholas A. Deason
Nicholas A. Deason
VMVictoria Makuru
Victoria Makuru
JDJenna Davidson
Jenna Davidson
HXHonglin Xiao
Honglin Xiao
NLNeil F. Lobo
Neil F. Lobo
Background: Molecular tools for detecting malaria-infected mosquitoes with improved practicality, sensitivity and specificity, and high-throughput are required. A common PCR technique used to detect mosquitoes infected with Plasmodium spp. is a nested PCR assay based on the 18s-rRNA gene. However, this technique has several technical limitations, is laborious and time consuming. Methods: In this study, a PCR-based on the Plasmodium cytochrome oxidase I (COX-I) gene was compared with the 18s-rRNA nested PCR using serial dilutions (330–0.0012 pg) of DNA from Plasmodium vivax, Plasmodium falciparum and Plasmodium knowlesi and with DNA from 48 positive and negative Kenyan mosquitoes (previously detected by using both ELISA and PCR). This assay for Plasmodium spp. DNA detection using the fast COX-I PCR assay was then performed individually on 2122 field collected mosquitoes (from the Solomon Islands) in which DNA was extracted from head and thorax. Results: The fast COX-I PCR assay took 1 h to run and consistently detected as low as to 0.043 pg of parasite DNA (equivalent to two parasites) in a single PCR, while analyses with the 18s-rRNA nested PCR required 4 h to complete with a consistent detection threshold of 1.5 pg of DNA. Both assays produced concordant results when applied to the 48 Kenyan control samples with known Plasmodium spp. infection status. The fast COX-I PCR identified 23/2122 Plasmodium-infected mosquitoes from the Solomon Islands. Conclusions: This new COX-I PCR adapted for a single PCR reaction is a faster, simpler, cheaper, more sensitive technique amenable to high-throughput analyses for Plasmodium DNA detection in mosquitoes and is comparable to the 18s-rRNA nested PCR. The improved sensitivity seen with the fast COX-I PCR will improve the accuracy of mosquito infection rate determination.

29 February 2016 in Malaria Journal
Verified
Journal Article
Open access
PDF file
DEDiego F. Echeverry
Diego F. Echeverry
NDNicholas A. Deason
Nicholas A. Deason
JDJenna Davidson
Jenna Davidson
VMVictoria Makuru
Victoria Makuru
HXHonglin Xiao
Honglin Xiao
NLNeil F. Lobo
Neil F. Lobo
Nested PCRs based on the Plasmodium 18s-rRNA gene have been extensively used for human malaria diagnosis. However, they are not practical when large quantities of samples need to be processed, further there have been challenges in the performance and when interpreting results, especially when submicroscopic infections are analysed. Here the use of “direct PCR” was investigated with the aim of improving diagnosis in the malaria elimination era. The performance of the Plasmodium cytochrome oxidase III gene (COX-III) based novel malaria detection strategies (direct nested PCR and direct single PCR) were compared using a 18s-rRNA direct nested PCR as a reference tool. Evaluations were based on sensitivity, specificity and the ability to detect mixed infections using control blood spot samples and field collected blood samples with final species diagnosis confirmation by sequencing. The COX-III direct PCR (limit of detection: 0.6–2 parasites/μL) was more sensitive than the 18s-rRNA direct nested PCR (limit of detection: 2–10 parasites/μL). The COX-III direct PCR identified all 21 positive controls (no mixed infections detected) while the 18s-rRNA direct nested PCR identified 18/21 (including four mixed infections). Different concentrations of simulated mixed infections (Plasmodium vivax and Plasmodium falciparum) suggest that the COX-III direct PCR detects only the predominant species. When the 18s-rRNA direct nested PCR was used to detect Plasmodium in field collected bloods spots (n = 3833), there was discrepancy in the results from the genus PCR (16 % positive) and the species-specific PCR (5 % positive). Further, a large portion of a subset of these positive samples (93 % for genus and 60 % for P. vivax), did not align with Plasmodium sequences. In contrast, the COX-III direct PCR clearly identified (single bands confirmed with sequencing) 2 % positive Plasmodium samples including P. vivax, P. falciparum, Plasmodium malariae and Plasmodium ovale wallikeri. The COX-III single direct PCR is an alternative method for accurate detection of Plasmodium microscopic and submicroscopic infections in humans, especially when a large number of samples require screening. This PCR does not require DNA isolation, is sensitive, quick, produces confident/clear results, identifies all the Plasmodium species infecting humans, and is cost-effective.

27 November 2018 in Parasites & Vectors
Verified
Journal Article
Open access
PDF file
TBTom Burkot
Tom Burkot
HBHugo Bugoro
Hugo Bugoro
AAAllan Apairamo
Allan Apairamo
RCRobert D. Cooper
Robert D. Cooper
DEDiego F. Echeverry
Diego F. Echeverry
TRTanya L. Russell
Tanya L. Russell
Decisions on when vector control can be withdrawn after malaria is eliminated depend on the receptivity or potential of an area to support vector populations. To guide malaria control and elimination programmes, the potential of biting rates, sporozoite rates, entomological inoculation rates and parity rates to estimate malaria receptivity and transmission were compared within and among geographically localised villages of active transmission in the Western Province of the Solomon Islands. Malaria transmission and transmission potential was heterogeneous in both time and space both among and within villages as defined by anopheline species composition and biting densities. Biting rates during the peak biting period (from 18:00 to 00:00 h) of the primary vector, Anopheles farauti, ranged from less than 0.3 bites per person per half night in low receptivity villages to 26 bites per person in highly receptive villages. Within villages, sites with high anopheline biting rates were significantly clustered. Sporozoite rates provided evidence for continued transmission of Plasmodium falciparum, P. vivax and P. ovale by An. farauti and for incriminating An. hinesorum, as a minor vector, but were unreliable as indicators of transmission intensity. In the low transmission area studied, sporozoite, entomological inoculation and parity rates could not be measured with the precision required to provide guidance to malaria programmes. Receptivity and potential transmission risk may be most reliably estimated by the vector biting rate. These results support the meaningful design of operational research programmes to ensure that resources are focused on providing information that can be utilised by malaria control programmes to best understand both transmission, transmission risk and receptivity across different areas.

18 October 2024 in Malaria Journal
Verified
Journal Article
Open access
PDF file
DEDiego F. Echeverry
Diego F. Echeverry
NDNicholas A. Deason
Nicholas A. Deason
VMVictoria Makuru
Victoria Makuru
JDJenna Davidson
Jenna Davidson
HXHonglin Xiao
Honglin Xiao
NLNeil F. Lobo
Neil F. Lobo