1 October 2008 in Progress in Neuro-Psychopharmacology and Biological Psychiatry
1 January 2008 in Progress in Neuro-Psychopharmacology and Biological Psychiatry
27 March 2008 in Magnetic Resonance in Medicine
This article addresses the problem of the tissue type parameter estimation in brain MRI in the presence of partial volume effects. Automatic MRI brain tissue classification is hampered by partial volume effects that are caused by the finite resolution of the acquisition process. Due to this effect intensity distributions in brain MRI cannot be well modeled by a simple mixture of Gaussians and therefore more complex models have been developed. Unfortunately, these models do not seem to be robust enough for clinical conditions, as the quality of the tissue classification decreases rapidly with the image quality. Also, the application of these methods for pathological images with unmodeled intensities (e.g. MS plaques, tumors, etc.) remains uncertain. In the present work a new robust method for brain tissue characterization is presented, treating the partial volume affected voxels as outliers of the pure tissue distributions. The proposed method estimates the tissue characteristics from a reduced set of intensities belonging to a particular pure tissue class. This reduced set is selected by using a trimming procedure based on local gradient information and distributional data. This feature makes the method highly tolerant of a large amount of unexpected intensities without degrading its performance. The proposed method has been evaluated using both synthetic and real MR data and compared with state‐of‐the‐art methods showing the best results in the comparative. Magn Reson Med 59:866–873, 2008.
1 March 2010 in Schizophrenia Research
1 September 2011 in Journal of Neurotrauma
The objective was to study the correlations and the differences in glucose metabolism between the thalamus and cortical structures in a sample of severe traumatic brain injury (TBI) patients with different neurological outcomes. We studied 49 patients who had suffered a severe TBI and 10 healthy control subjects using 18F-fluorodeoxyglucose positron emission tomography (18F-FDG-PET). The patients were divided into three groups: a vegetative or minimally-conscious state (MCS&VS) group (n=17), which included patients who were in a vegetative or a minimally conscious state; an In-post-traumatic amnesia (In-PTA) group (n=12), which included patients in PTA; and an Out-PTA group (n=20), which included patients who had recovered from PTA. SPM5 software was used to determine the metabolic differences between the groups. FDG-PET images were normalized and four regions of interest were generated around the thalamus, precuneus, and the frontal and temporal lobes. The groups were parameterized using Student's t-test. Principal component analysis was used to obtain an intensity-estimated-value per subject to correlate the function between the structures. Differences in glucose metabolism in all structures were related to the neurological outcome, and the most severe patients showed the most severe hypometabolism. We also found a significant correlation between the cortico-thalamo-cortical metabolism in all groups. Voxel-based analysis suggests a functional correlation between these four areas, and decreased metabolism was associated with less favorable outcomes. Higher levels of activation of the cortico-cortical connections appear to be related to better neurological condition. Differences in the thalamo-cortical correlations between patients and controls may be related to traumatic dysfunction due to focal or diffuse lesions.
1 January 2009 in International Journal of Biomedical Imaging
Magnetic Resonance images are normally corrupted by random noise from the measurement process complicating the automatic feature extraction and analysis of clinical data. It is because of this reason that denoising methods have been traditionally applied to improve MR image quality. Many of these methods use the information of a single image without taking into consideration the intrinsic multicomponent nature of MR images. In this paper we propose a new filter to reduce random noise in multicomponent MR images by spatially averaging similar pixels using information from all available image components to perform the denoising process. The proposed algorithm also uses a local Principal Component Analysis decomposition as a postprocessing step to remove more noise by using information not only in the spatial domain but also in the intercomponent domain dealing in a higher noise reduction without significantly affecting the original image resolution. The proposed method has been compared with similar state‐of‐art methods over synthetic and real clinical multicomponent MR images showing an improved performance in all cases analyzed.