Yuanrui Zhou

Yuanrui Zhou

Auto-generated profile, based on publicly available information

Yuanrui Zhou

College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YSYongze Sun
Yongze Sun
Xixi WangXixi Wang
Xixi Wang
YZYuanrui Zhou
Yuanrui Zhou
JQJianan Qin
Jianan Qin
DBDongxu Bai
Dongxu Bai
ZZZhijian Zhou
Zhijian Zhou
The mouse Magnetocardiogram’s (MCG) accurate measurement is of the utmost importance for studying heart diseases. However, most of the currently used measuring instruments are Superconducting Quantum Interference Devices (SQUIDs), which are quite problematic. For example, they have a large scale, are expensive, and are difficult to widely promote. To address these issues, we present a mouse MCG measurement system using a Spin-Exchange-Relaxation-Free (SERF) atomic magnetometer. The measurement system mainly consists of a magnetic sensor, a mouse fixation device, a magnetically shielded device, and a data acquisition and processing module. We fabricated a single-axis SERF rubidium atomic magnetometer with a sensitivity of 20 fT/ √ Hz to serve as the system’s magnetic sensor. We also conducted experiments on the mouse MCG signals. Using power line harmonic modeling and wavelet threshold filter processing, we processed the raw signal and obtained an R -peak amplitude of 5 pT; moreover, the P -, QRS -, and T -waves were clearly visible. We also performed heart rate monitoring on mice at different ambient temperatures. Finally, we conducted a comparative analysis of related systems to illustrate the proposed system’s advantages for mouse MCG signals. This work demonstrates that the SERF atomic magnetometer is compatible with the long-term detection needs of the mouse cardiac magnetic field.

21 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JQJianan Qin
Jianan Qin
YZYuanrui Zhou
Yuanrui Zhou
YWYanzhang Wang
Yanzhang Wang
The spin-exchange-relaxation-free atomic magnetometer (SERF-AM) is a promising new technology that can replace superconducting quantum interference devices (SQUIDs) for many applications. However, the characteristic of the SERF-AM that the alkali atom vapor must be in a near-zero magnetic field is a huge obstacle to the applications in an unshielded environment. A real-time magnetic field compensation method can replace the shielding device to allow the SERF-AM to operate in the unshielded environment. For this, the current source that drives the compensation coil should have a high dynamic range at least 120 dB, ultralow-noise below 1 nA/Hz $^{\mathrm {1/2}}$ /A, and bipolar output capability. In this work, we propose a programmable current source with two digital-to-analog converters (DACs), which achieves a high current resolution of 4 nA with a maximum output current of ±202 mA and a fast response within a range of 4 mA. A parallel structure of two-stage current sources is applied to improve the loop stability of the system and a noise level of 28.3 pA/Hz $^{\mathrm {1/2}}$ @10 Hz was achieved with an output current of 150 mA.

13 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YSYongze Sun
Yongze Sun
YZYuanrui Zhou
Yuanrui Zhou
XWXixi Wang
Xixi Wang
DBDongxu Bai
Dongxu Bai
YWYanzhang Wang
Yanzhang Wang
ZZZhijian Zhou
Zhijian Zhou
The measurement of remanent magnetic moments in rocks is essential for the study of paleomagnetism and rock magnetism. However, it is challenging to achieve high sensitivity non-destructive detection of residual magnetic moments in large samples. Using SQUID-based measurement systems for large sample measurements necessitates sample sampling, potentially causing sample damage, and is associated with the high cost of the equipment. Using coils, magnetic flux gates, and similar methods for measurement also struggles to provide highly sensitive magnetic moment information. To address the challenge of low-cost, high-sensitivity, and wide-range magnetic moment measurements, this paper presents a prototype residual Magnetic Moment Measurement System (MMMS) based on a compact single-axis Spin-Exchange Relaxation-Free (SERF)atomic magnetometer. The paper begins by elucidating the fundamental principles of using an atomic magnetometer for magnetic moment measurements. It then provides a detailed account of the instrument’s design, fabrication, and the results of various performance tests. In the end, a measurement system with a range of 1 × 10 -11 ~ 1.28 × 10 -5 Am 2 is achieved. In terms of theoretical sensitivity, it is comparable to SQUID measurement systems. We also propose a rapid method for measuring the magnetic moments of large samples and demonstrate its application on actual basalt samples. This work underscores the potential of a compact single-axis SERF atomic magnetometer for cost-effective and highly sensitive detection of the remanent magnetic moments of rocks.

21 June 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DBDongxu Bai
Dongxu Bai
YZYuanrui Zhou
Yuanrui Zhou
YSYongze Sun
Yongze Sun
HYHongfei Yang
Hongfei Yang
YWYanzhang Wang
Yanzhang Wang
The Bell-Bloom atomic magnetometer is a high sensitivity magnetic field measuring instrument. It utilizes the free precession signal of polarized atoms to obtain the magnetic field measurement. However, the complexity of the free precession signal makes it difficult for the magnetometer to measure magnetic field information, which severely limits the application of the magnetometer. In this study, to solve this problem, a free precession frequency (FPF) measurement system is designed for the Bell-Bloom atomic magnetometer, which successfully achieves accurate, fast, and efficient frequency counting of the free precession signal. Based on the analysis results of signal characteristics, the FPF measurement system was designed and tested. The equivalent instrument sensitivity can reach 10 pT/√Hz in the frequency range corresponding to the magnetic field of 40-60 μT, and the system can work continuously for a long time. The system operates stably with independence within the temperature range of 275K to 350K and can be further enhanced through an external temperature control system. Regarding measurement stability, the median repeatability of frequency measurement results exceeds 0.6 Hz. The FPF measurement system effectively addresses the complexities associated with the free precession signal, and meeting the magnetic field measurement requirements of the Bell-Bloom atomic magnetometer.

20 December 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
TXTiexiao Xu
Tiexiao Xu
ZWZhuo Wang
Zhuo Wang
LZLinshan Zhong
Linshan Zhong
YZYuanrui Zhou
Yuanrui Zhou
This paper introduces innovative approaches to assess the stability and stabilizability of nonlinear interval systems, offering efficient methods for designing state feedback stabilization controllers. Stability analysis relies on matrix theory and Lyapunov’s method, providing less conservative results compared to conventional techniques. Stabilizability analysis presents conditions for achieving stabilizability and designing feedback stabilization controller, reducing computational complexity. The effectiveness and advantages of these methods are illustrated through examples.

1 January 2026 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
LCLinhan Cheng
Linhan Cheng
LSLihan Sun
Lihan Sun
YZYuanrui Zhou
Yuanrui Zhou
QXQuan Xu
Quan Xu
YWYanzhang Wang
Yanzhang Wang