Study Design. Repeated measures for intratester reliability were performed. Objectives. To investigate the intratester reliability of a new measurement technique that evaluates lumbar range of motion in three planes using a pelvic restraint device, and to examine the reliability of lumbar lordosis measurement by inclinometer technique. Preliminary normative data on lumbar range of motion and lumbar lordosis were collected for comparison with the findings of previous studies. Summary of Background Data. Various noninvasive measurement methods have been developed for recording lumbar range of motion. However, pelvic movement was not effectively restricted during the use of these measurement techniques. The use of the pelvic restraint device to measure lumbar range of motion has not been investigated previously. Very few studies have investigated the reliability of quantifying lumbar lordosis by the inclinometer technique. Methods. Normative values were measured in 35 healthy men, and 12 of these subjects were included for the reliability study. Pelvic motion was limited by the pelvic restraint device during lumbar range of motion measurement in standing. An inclinometer was used for evaluation of lumbar flexion, extension, lateral flexion, and lumbar lordosis, whereas a lumbar rotameter was used to measure axial rotation. Results. Good intratester reliability was shown in the lumbar range of motion and lordosis measurement. Most of the intraclass correlation coefficient and Pearson’s r values (accompanied with nonsignificant paired t tests) were greater than 0.9, and most of the intrasubject coefficients of variation were less than 10%. The values of lumbar range of motion in three planes and lumbar lordosis found in the current study were comparable with those from most of the previous studies on these measurements in the normal population. Conclusions. Inclinometer and lumbar rotameter measurements with the use of a pelvic restraint device are reliable for measuring lumbar spine range of motion. Use of the inclinometer technique to record lumbar lordosis also is a reliable measure.
Background and Purpose. Muscle endurance is an important variable to measure in the assessment of back muscle function. This study investigated the electromyographic (EMG) activity and fatigue patterns of iliocostalis lumborum and multifidus muscles during a trunk holding test. Subjects. Sixteen male subjects (mean age=24.2 years, SD=4.2, range=20.6–31.9) without low back pain or known pathology were recruited in the study. Methods. Surface EMG electrodes were used to record the activity of iliocostalis lumborum and mutifidus muscles during a 60-second isometric contraction. To reflect the activity level and fatigue rate of the muscles, EMG amplitude (root mean square [RMS] values) and a frequency variable (median frequency [MF]) were measured. Results. The multifidus muscle displayed a higher level of activity, initial MF, and normalized MF slope than did the iliocostalis lumborum muscle. There was no difference, however, in the normalized RMS slope between the two muscles. The correlations between the normalized MF slope and the RMS slope of the two muscles were nonsignificant. Conclusion and Discussion. This study shows that monitoring frequency changes of the EMG signals may enable therapists to quantify the fatigue changes of individual muscles during the trunk holding test. The higher fatigue rate shown in the multifidus muscle compared with the iliocostalis lumborum muscle may be due to the higher activity level of the multifidus muscle during the trunk holding contraction. This greater activity of the multifidus muscle during the contraction might be explained by the functional differences between these two muscles.