Department of Family Medicine and Primary Care, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
Auto-generated profile, based on publicly available information
Emily Tsui Yee Tse
Department of Family Medicine and Primary Care, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
Introduction: More than half of diabetes mellitus (DM) and pre‐diabetes (pre‐DM) cases remain undiagnosed, while existing risk assessment models are limited by focusing on diabetes mellitus only (omitting pre‐DM) and often lack lifestyle factors such as sleep. This study aimed to develop a non‐laboratory risk assessment model to detect undiagnosed diabetes mellitus and pre‐diabetes mellitus in Chinese adults.Methods: Based on a population‐representative dataset, 1,857 participants aged 18–84 years without self‐reported diabetes mellitus, pre‐diabetes mellitus, and other major chronic diseases were included. The outcome was defined as a newly detected diabetes mellitus or pre‐diabetes by a blood test. The risk models were developed using logistic regression (LR) and interpretable machine learning (ML) methods. Models were validated using area under the receiver‐operating characteristic curve (AUC‐ROC), precision‐recall curve (AUC‐PR), and calibration plots. Two existing diabetes mellitus risk models were included for comparison.Results: The prevalence of newly diagnosed diabetes mellitus and pre‐diabetes mellitus was 15.08%. In addition to known risk factors (age, BMI, WHR, SBP, waist circumference, and smoking status), we found that sleep duration, and vigorous recreational activity time were also significant risk factors of diabetes mellitus and pre‐diabetes mellitus. Both LR (AUC‐ROC = 0.812, AUC‐PR = 0.448) and ML models (AUC‐ROC = 0.822, AUC‐PR = 0.496) performed well in the validation sample with the ML model showing better discrimination and calibration. The performance of the models was better than the two existing models.Conclusions: Sleep duration and vigorous recreational activity time are modifiable risk factors of diabetes mellitus and pre‐diabetes in Chinese adults. Non‐laboratory‐based risk assessment models that incorporate these lifestyle factors can enhance case detection of diabetes mellitus and pre‐diabetes.
18 December 2021 in Health and Quality of Life Outcomes
Background: Electronic measurement of health-related quality of life (HRQOL) may facilitate timely and regular assessments in routine clinical practice. This study evaluated the validity and psychometric properties of an electronic version of the EQ-5D-5L (e-EQ-5D-5L) in Chinese patients with chronic knee and/or back problems. Methods: 151 Chinese subjects completed an electronic version of the Chinese (Hong Kong) EQ-5D-5L when they attended a primary care or orthopedics specialist out-patient clinic in Hong Kong. They also completed the Chinese Western Ontario and McMaster University Osteoarthritis Index (WOMAC), a Pain Rating Scale, and a structured questionnaire on socio-demographics, co-morbidities and health service utilization. 32 subjects repeated the e-EQ-5D-5L two weeks after the baseline. 102 subjects completed e-EQ-5D-5L and 99 completed the Global Rating on Change Scale at three-month clinic follow up. Construct validity was assessed by the association of EQ-5D-5L scores with external criterion of WOMAC scores. We tested mean differences of WOMAC scores between adjacent response levels of the EQ-5D-5L dimensions by one-way ANOVA, test–retest reliability by intra-class correlation, sensitivity by known group comparisons and responsiveness by changes in EQ-5D-5L scores over 3 months. Results: There was an association between EQ-5D-5L and WOMAC scores. Mean WOMAC scores increased with the increase in adjacent response levels of EQ-5D-5L dimensions. Test–retest intraclass correlation coefficient (ICC) of EQ-5D-5L utility and EQ-VAS scores were 0.76 and 0.83, respectively, indicating good reliability. There were significant differences in the proportions reporting limitations in the EQ-5D-5L dimensions, the utility and VAS scores between the mild and severe pain groups (utility = 0.28, p = 0.001; VAS = 11.46, p < 0.001), and between primary care and specialist out-patient clinic patients (utility = 0.15, p = 0.001; VAS = 10.21, p < 0.001), supporting sensitivity. Among those reporting ‘better’ global health at three-months, their EQ-5D-5L utility and EQ-VAS scores were significantly increased from baseline (utility = 0.18, p < 0.001; VAS = 10.75, p = 0.005). Conclusions: The electronic version of the EQ-5D-5L is valid, reliable, sensitive and responsive in the measurement of HRQOL in Chinese patients with chronic knee or back pain in routine clinical practice.
Objectives To highlight the prevalence of sleep problems and identify associated risk factors among a representative sample recruited from the general population of Hong Kong. Design, setting and participants Participants included 12 022 individuals (aged 15 or above) who took part in the Population Health Survey 2014/15, a territory-wide survey conducted by the Department of Health of the Government of the Hong Kong Special Administrative Region. Primary and secondary outcome measures Outcomes were the prevalence of (1) insufficient sleep (<6 hours sleep per day) and (2) any sleep disturbance (difficulty initiating sleep, intermittent awakenings, early awakening) ≥3 times per week in the past 30 days. Multivariable logistic regression identified associations between sleep problems and sociodemographic, clinical and lifestyle factors. Results 9.7% of respondents reported insufficient sleep and 10.5% reported sleep disturbances ≥3 times a week. Female gender, monthly household income <$12 250 (Hong Kong dollar), lower education level, mental health condition and physical health condition were significantly associated with both insufficient and disturbed sleep (all p<0.05). Unemployment, homemaker, insufficient physical activity, current/former smoking status and harmful alcohol consumption were associated with sleep disturbances only (all p<0.01). Conclusions Sleep problems are highly prevalent in Hong Kong. As such problems are associated with a range of health conditions, it is important to facilitate improvements in sleep. Our results show that harmful alcohol consumption, insufficient physical activity and current smoking are modifiable risk factors for sleep disturbances. Public health campaigns should focus on these risk factors in order to promote a healthy lifestyle and ultimately reduce sleep disturbances. Targeted interventions for high-risk groups may also be warranted, particularly for those with doctor-diagnosed physical and mental health conditions.
Objectives To evaluate the validity and psychometric properties of the Chinese Person-Centred Primary Care Measure (PCPCM) in a Chinese-speaking population. Design A cross-sectional study. Setting A primary care clinic in Hong Kong. Participants 300 Chinese adult patients (150 males and 150 females) were recruited from a primary care clinic to complete a questionnaire containing the PCPCM, Consultation and Relational Empathy (CARE), Patient Enablement Index (PEI) and Adult (short version) Primary Care Assessment Tool (PCAT). The Chinese PCPCM was readministered to 118 participants after 14 days for test–retest reliability. Outcome measures The construct validity, reliability and sensitivity of the Chinese PCPCM. Results The Chinese PCPCM was identified to have a one-factor construct, with good item fit and unidimensionality on Rasch analysis. Internal reliability was high (Cronbach’s alpha >0.8) with moderate test–retest reliability (intraclass correlation coefficient=0.622, p<0.001). Significant correlations (0.58, 0.42, 0.48) between the PCPCM and CARE, PEI and Adult (short version) PCAT scores supported good convergent construct validity. PCPCM scores were higher among patients who had known their doctors for a longer period or who were more likely to be able to see the same doctor at every visit, and among those who self-reported to have ‘better health’ rather than ‘worse health’. Conclusion The Chinese PCPCM appears to be a valid, reliable and sensitive instrument for evaluating the quality of person-centred care among primary care patients in Hong Kong. Further studies are needed to confirm the utility of this instrument in other Chinese-speaking populations around the world.
22 September 2020 in Family Medicine and Community Health
Objectives To develop an equivalent Chinese translation of the Person-Centered Primary Care Measure (PCPCM) and to establish its cultural adaptability and content validity through cognitive debriefing. Design The original English PCPCM was first translated into Chinese by double forward-translation by professional translators. The reconciliated Chinese version was then doubly back-translated into English by two other professional translators blinded to the forward-translation. On affirmation on its linguistic equivalence with the developers of the original English PCPCM, the reconciliated Chinese PCPCM was sent for cognitive debriefing with 20 Chinese-speaking primary care subjects by a trained interviewer using structured probing questions to collect their opinions on the clarity, comprehensibility and relevance of each item and response option in the Measure. Setting Subjects were invited from a primary care clinic in Hong Kong to undergo the cognitive debriefing interviews. The interviews were divided into four groups chronologically to allow revision of the items to be made in between. Participants Ten males and 10 females above the age of 18 completed the cognitive interviews. They were all Cantonese-speaking Chinese recruited by convenience sampling. Subjects with cognitive impairment, could not read Chinese, too old or too sick to complete the interviews were excluded from the study. Results An average of 3.3 min (range 3–4 min) was required for the subjects to self-complete the Measure. All items were generally perceived to be easily understood and relevant. Modifications were made to items with the content validity index (CVI) on clarity or understanding <0.8 in each round of the interviews or if a majority of the subjects suggested rewording. Revisions were made to two items in the Chinese PCPCM throughout the whole cognitive debriefing process before the final version was confirmed. The average CVI on clarity of the Chinese PCPCM items ranged from 0.75 to 1. The average CVI on understanding ranged from 0.7 to 1. The average CVI on relevance ranged from 0.55 to 1. Conclusions The content validity of the PCPCM was ascertained in terms of its clarity, understandability and relevance to allow further testing of its psychometric properties in a larger Chinese population.
Patient enablement is a core tenet of patient-centred and holistic primary care. The Patient Enablement Instrument (PEI) is a transitional measure limited in its ability to measure changes over time. A modified version, PEI-2, has been developed to measure enablement at a given time-point without comparison to a recalled baseline. To assess the validity, reliability, sensitivity and responsiveness of PEI-2. PEI-2 was modified from the Chinese PEI to assess enablement over 4 weeks in a prospective cohort study nested within a community support programme [Trekkers Family Enhancement Scheme (TFES)] in Hong Kong. Construct validity was assessed by factor analysis and convergent validity by Spearman’s correlations with health-related quality of life and depressive symptoms. Internal reliability was assessed using Cronbach’s alpha. Test–retest reliability was assessed by intraclass correlation (ICC), responsiveness by 12–24-month change in PEI-2 score and sensitivity by differences in change of PEI-2 score between TFES participants and a control group. PEI-2 demonstrated construct validity with all items loading on one factor (factor loadings >0.7). Convergent validity was confirmed by significant correlations with 12-item Short Form Questionnaire, version 2 (r = 0.1089–0.1919) and Patient Health Questionnaire-9 (r = −0.2030). Internal reliability was high (Cronbach’s alpha = 0.9095) and test–retest reliability moderate (ICC = 0.520, P = 0.506). Significant improvements in PEI-2 scores among the TFES group suggested good responsiveness (P < 0.001). The difference in change of PEI-2 scores between TFES and control was significant (P = 0.008), indicating good sensitivity. This study supports the validity, reliability, sensitivity and responsiveness of PEI-2 in measuring changes in enablement, making it a promising tool for evaluating enablement in cohort and intervention studies.