A novel microfiber sensor is proposed and demonstrated based on a singlemode-tapered hollow core -singlemode (STHS) fiber structure. Experimentally a STHS with taper waist diameter of 26.5 μm has been fabricated and RI sensitivity of 816, 1601.86, and 4775.5 nm/RIU has been achieved with RI ranges from 1.3335 to 1.3395 , from 1.369 to 1.378, and from 1.409 to 1.4175 respectively, which agrees very well with simulated RI sensitivity of 885, 1517, and 4540 nm/RIU at RI ranges from 1.3335 to 1.337, from 1.37 to 1.374, and from 1.41 to 1.414 . The taper waist diameter has impact on both temperature and strain sensitivity of the sensor structure: (1) the smaller the waist diameter, the higher the temperature sensitivity, and experimentally 26.82 pm/°C has been achieved with a taper waist diameter of 21.4 μm; (2) as waist diameter decrease, strain sensitivity increase and 7.62 pm/με has been achieved with a taper diameter of 20.3 μm. The developed sensor was then functionalized for human chorionic gonadotropin (hCG) detection as an example for biosensing application. Experimentally for hCG concentration of 5 mIU/ml, the sensor has 0.5 nm wavelength shift, equivalent to limit of detection (LOD) of 0.6 mIU/ml by defining 3 times of the wavelength variation (0.06 nm) as measurement limit. The biosensor demonstrated relatively good reproducibility and specificity, which has potential for real medical diagnostics and other applications.
Nanomechanical measurements, especially the detection of weak contact forces, play a vital role in many fields, such as material science, micromanipulation, and mechanobiology. However, it remains a challenging task to realize the measurement of ultraweak force levels as low as nanonewtons with a simple sensing configuration. In this work, an ultrasensitive all-fiber nanonewton force sensor structure based on a single-mode–tapered U-shape multimode–single-mode fiber probe is proposed and experimentally demonstrated with a limit of detection of ~5.4 nanonewtons. The use of the sensor is demonstrated by force measurement on a human hair sample to determine the spring constant of the hair. The results agree well with measurements using an atomic force microscope for the spring constant of the hair. Compared with other force sensors based on optical fiber in the literature, the proposed all-fiber force sensor provides a substantial advancement in the minimum detectable force possible, with the advantages of a simple configuration, ease of fabrication, and low cost.