Yu-Ying Wu

Yu-Ying Wu

Auto-generated profile, based on publicly available information

Yu-Ying Wu

State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YWYu-Ying Wu
Yu-Ying Wu
YXYan-Zhao Xie
Yan-Zhao Xie
YGYan-Peng Ge
Yan-Peng Ge
YWYu-Bo Wang
Yu-Bo Wang
ZLZe-Tong Li
Ze-Tong Li
HCHan Cao
Han Cao
Metal-oxide arresters (MOA), including the non-gapped MOAs (NG-MOA) and externally-gapped MOAs (EG-MOA), are the main equipment applied to protect the power system against conducted transient electromagnetic disturbances (TED). However, MOAs exhibit quite different electrical characteristics under microsecond-level and nanosecond-level transients. In order to figure out the response of MOAs under nanosecond-level TED, experimental platforms are built which contain a pulse generator with the amplitude of pulse current adjustable from 0 kA to 5 kA and the rise time of 20 ns. Then the dynamic hysteresis loops, the static V-I characteristics, the response time delay and the full response process of five types of 10-kV MOAs are investigated. From the dynamic hysteresis loops of NG-MOAs, the impedance conversion process can be seen clearly and can be explained by the grain-boundary theory. But EG-MOAs has not this conversion process due to the air-gap. And the experimental results demonstrate that there is no noticeable nanosecond-level conduction delay on NG-MOAs whereas the electric field non-uniformity of the air-gap has a significant influence on the time delay of the EG-MOAs. The response time delay of EG-MOAs changes ranging from tens of nanoseconds to hundreds of nanoseconds. This feature makes EG-MOAs more likely to raise insulation risks under nanosecond-level TED compared with NG-MOAs.

9 March 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YGYan-Peng Ge
Yan-Peng Ge
YXYan-Zhao Xie
Yan-Zhao Xie
TLTao Liang
Tao Liang
NDNing Dong
Ning Dong
YWYu-Ying Wu
Yu-Ying Wu
YZYi Zhou
Yi Zhou
Metal-oxide arresters (MOA) are widely used to protect equipment against transient electromagnetic disturbances (TED) like very fast transient overvoltage (VFTO), high-altitude electromagnetic pulse (HEMP), lightning pulse, et al. Researches on the performance of MOA under microsecond level rise-time TED are abundant, such as lightning pulse. However, when MOA is subjected to TED of rise-time at nanosecond level, the voltage/current responses of MOA are not fully studied due to the lack of a standardized and reliable test setup. In this paper, a test setup is proposed for acquiring the response behavior of MOA under nanosecond level pulse. The setup is comprised of a pulse generator, a two-branch transmission line system and a high voltage power divider. The generator can provide stable double exponential pulse with tunable rise-time ranging from 5 ns to 100 ns. The divider ensures an even distribution of voltage/current surge wave along the two-branch line. Through the numerical analysis, both impinging and residual surge waveforms could be retrieved from measurements. The proposed method has been applied to investigate response behavior of MOA subjected to nanosecond level rise-time pulses.

22 February 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
NDNing Dong
Ning Dong
YXYan-Zhao Xie
Yan-Zhao Xie
YWYuying Wu
Yuying Wu
ZLZetong Li
Zetong Li
Flavio CanaveroFlavio Canavero
Flavio Canavero
The existing models of the Metal-Oxide arresters (MOA) have difficulty covering the behavior prediction under surges with front time ranging from microseconds to nanoseconds. This paper presents an equation-based dynamic nonlinear model and its circuit implementation, which can describe the behavior of the MOA in a wide range of frequencies and amplitudes with the consideration of the piecewise nonlinearity and the dynamic nonlinearity characteristics. The model can be easily constructed based on the manufacturer’s data and a multiplication factor table for the dynamic characteristic. Two types of MOA used in the power distribution systems are tested to validate the proposed model. The simulated responses of MOAs are in good agreement with the measured results when the MOAs are applied to impulses with front time ranging from 20 ns to 30 ls. Both the errors of the peak voltage and the absorbed energy between simulated and measured results are less than 6%.

12 June 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YWYu-Ying Wu
Yu-Ying Wu
YXYan-Zhao Xie
Yan-Zhao Xie
NDNing Dong
Ning Dong
FTFu-Zheng Tian
Fu-Zheng Tian
The dynamic models of the metal-oxide varistors (MOV) have been developed successively and they show good performances in the prediction of the residual voltage. However, energy absorption, one of the most important electrical characteristics of MOV, is also worth studying, because it is a non-negligible factor to evaluate the accuracy of the model. This paper proposes a dynamic nonlinear model for MOV considering the residual voltage and the energy absorption under wide-range transients with the rise time ranging from 20 ns to 30 μs. During modeling, the characteristics of the propose model including the capacitance, the inductance and the nonlinear resistance are studied first. Then the electrical circuit is developed in ATP-EMTP. The performance of the proposed model is analyzed and compared with the IEEE model. The results indicate that the proposed model is accurate and reliable in calculating both the residual voltage and the energy, and the maximum relative errors of the residual voltage and the energy are 5.74% and 5.29%, respectively.

28 June 2023 in IEEE Letters on Electromagnetic Compatibility Practice and Applications
Verified
Journal Article
Closed access
YWYu-Ying Wu
Yu-Ying Wu
YXYan-Zhao Xie
Yan-Zhao Xie
HCHan Cao
Han Cao
NDNing Dong
Ning Dong
YGYan-Peng Ge
Yan-Peng Ge
This paper summarizes the existing test methods for protective devices and the waveforms of conducted transient electromagnetic disturbance in different standards. However, they mainly focus on the testing methods for the residual current of the protective devices or the response behaviors of coaxial protector. To quantify the response performance of protection devices used in the power distribution system excited by electromagnetic transients, an optimal test method is then proposed. The test setup consists of a pulse generator, an absorption resistor, transmission lines and the measurement system. The test results and simulation results of 10-kV non-gapped metal-oxide arrester verify the validation of the proposed method. By using the proposed method, the applied current and the current flowing through protective devices can be calculated so that the response time can be evaluated. Besides, this method can also be used to study the response of protective devices under other different disturbances.

1 November 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DZDao-Zhong Zhang
Dao-Zhong Zhang
YXYan-Zhao Xie
Yan-Zhao Xie
YZYi Zhou
Yi Zhou
YWYu-Ying Wu
Yu-Ying Wu
YZYun-Peng Zhang
Yun-Peng Zhang
High-altitude electromagnetic pulse (HEMP) has attracted considerable attention for its influence on electrical equipment. HEMP is divided into three parts: early time HEMP (E1), intermediate-time HEMP (E2), and late-time HEMP (E3). Most studies focused on E1 alone, while few investigated others. However, the electrical equipment may be disturbed by more than one part since these three parts co-exist in a HEMP environment. The pulse current injection (PCI) test is an effective immunity test method for evaluating the sensitivity and susceptibility of electrical equipment. To investigate the responses of electrical equipment excited by the consecutive E1 and E2 and compare with those under the individual E1 or E2, this paper builds a PCI platform that can carry out PCI tests with the consecutive E1 and E2 conducted current. To output the E1 current and the E2 current consecutively, which exhibit significant differences in the rise time (20 ns and 1.5 μs), peak current (2500 and 250 A), and full width at half maximum (FWHM, 500–550 ns and 3–5 ms), an E1&E2 coupler with a fast-closing high-current trigger switch is designed in this paper. Finally, some 10-kV epoxy insulators are tested in the developed platform, which shows the capacity of the proposed platform to test the immunity of electrical equipment with the consecutive E1 and E2 conducted current.