16 January 2023 in Nuclear Science and Techniques
Nuclear security usually requires the simultaneous detection of neutrons and gamma rays. With the development of crystalline materials in recent years, Cs2LiLaBr6 (CLLB) dual-readout detectors have attracted extensive attention from researchers, where real-time neutron/gamma pulse discrimination is the critical factor among detector performance parameters. This study investigated the discrimination performance of the charge comparison, amplitude comparison, time comparison, and pulse gradient methods and the effects of a Sallen–Key filter on their performance. Experimental results show that the figure of merit (FOM) of all four methods is improved by proper filtering. Among them, the charge comparison method exhibits excellent noise resistance; moreover, it is the most suitable method of real-time discrimination for CLLB detectors. However, its discrimination performance depends on the parameters $${t}_\text{s}$$ , $${t}_\text{m}$$ , and $${t}_\text{e}$$ . When $${t}_\text{s}$$ corresponds to the moment at which the pulse is at 10% of its peak value, $${t}_\text{e}$$ requires a delay of only 640–740 ns compared to $${t}_\text{s}$$ , at which time the potentially optimal FOM of the charge comparison method at 3.1–3.3 MeV is greater than 1.46. The FOM obtained using the $${t}_\text{m}$$ value calculated by a proposed maximized discrimination difference model (MDDM) and the potentially optimal FOM differ by less than 3.9%, indicating that the model can provide good guidance for parameter selection in the charge comparison method.
25 October 2023 in Nuclear Science and Techniques
18 March 2022 in Nuclear Science and Techniques
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak (EAST). The measurement result of neutron flux monitoring (NFM) is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity. Therefore, a wide range and high time resolution are required for the NFM system on EAST. To satisfy these requirements, a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed. The present study was conducted using a field-programmable gate array (FPGA) and peripheral component interconnect extension for instrument express (PXIe) platform. The digital dual measurement modes, which are composed of the pulse-counting mode and AC coupled square integral’s Campbelling mode, were designed to expand the measurement range of the signal acquisition and processing system. The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing high-speed analog-to-digital converters (ADCs), a high-speed PXIe communication with a direct memory access (DMA) mode, and online data preprocessing technology of FPGA. The signal acquisition and processing system was tested experimentally in the EAST radiation field. The test results showed that the time resolution of NFM was improved to 1 ms, and the dynamic range of the neutron counts rate was expanded to more than $$10^{6}$$ counts per second. The Campbelling mode was calibrated using a multipoint average linear fitting method; subsequently, the fitting coefficient reached 0.9911. Therefore, the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.
6 July 2021 in Nuclear Science and Techniques
1 November 2021 in Fusion Engineering and Design
20 January 2020 in EPJ Web of Conferences
International Thermonuclear Experimental Reactor (ITER) Radial X-ray Camera (RXC) is installed in the equatorial port #12 (middle drawer) to measure the poloidal profile of the plasma x-ray emission with high spatial and temporal resolution. According to the irradiation test results with Co-60 gamma ray source, Cf-252 neutron source and the result in Deuterium - Tritium (DT) accelerator neutron irradiation experiment for RXC electronics before, the weak parts of the circuit have been improved by radiation resistance design such as using radiation-hard power chip and optimizing the Field Programmable Gate Array (FPGA) code. Other factors related to radiation, such as easiness of maintenance, compact electronics structure and remote state monitoring are also considered in the design. The performance of the electronics and chassis has been preliminarily verified in Experimental Advanced Superconducting Tokamak (EAST) experiments showing resistance to interference from discharge environment. Besides, the irradiation resistance of electronics was investigated in high fluence neutron irradiation experiment in fission reactor, where the detector, pre-amplifier, mid-amplifier and cables under test received the accumulated neutron fluence over 9.89×1013n/cm-2 (1MeV equivalent), and the quality of output signal was monitored in real time. It’s found after the experiment that the pre-amplifier worked well, while the detector and mid-amplifier were partly damaged.