Hadi Bahrami

Hadi Bahrami

Auto-generated profile, based on publicly available information

Hadi Bahrami

Huawei Technologies Canada Co. Ltd., Suite 400, 303 Terry Fox Drive, Kanata, Ontario K2K 3J1, Canada

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2016 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Emily PorterEmily Porter
Emily Porter
HBHadi Bahrami
Hadi Bahrami
ASAdam Santorelli
Adam Santorelli
Benoit GosselinBenoit Gosselin
Benoit Gosselin
LRLeslie Rusch
Leslie Rusch
MPMilica Popovic
Milica Popovic
In this work, we present a clinical prototype with a wearable patient interface for microwave breast cancer detection. The long-term aim of the prototype is a breast health monitoring application. The system operates using multistatic time-domain pulsed radar, with 16 flexible antennas embedded into a bra. Unlike the previously reported, table-based prototype with a rigid cup-like holder, the wearable one requires no immersion medium and enables simple localization of breast surface. In comparison with the table-based prototype, the wearable one is also significantly more cost-effective and has a smaller footprint. To demonstrate the improved functionality of the wearable prototype, we here report the outcome of daily testing of the new, wearable prototype on a healthy volunteer over a 28-day period. The resulting data (both signals and reconstructed images) is compared to that obtained with our table-based prototype. We show that the use of the wearable prototype has improved the quality of collected volunteer data by every investigated measure. This work demonstrates the proof-of-concept for a wearable breast health monitoring array, which can be further optimized in the future for use with patients with various breast sizes and tissue densities.

31 January 2012 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
APAbbas Pirhadi
Abbas Pirhadi
HBHadi Bahrami
Hadi Bahrami
JNJavad Nasri
Javad Nasri
In this communication a high directive electromagnetic bandgap (EBG) antenna operating in wide frequency band for both return loss (RL) and directivity is examined. In this EBG antenna an aperture coupled microstrip antenna (ACMA) is used as a feeding source and a frequency selective surface (FSS) is used as a superstrate layer. Suitable use of the superstrate layer, microstrip patch and coupling aperture simultaneously, leads to produce separate resonance frequencies and therefore the wide frequency band for RL. Also, high directivity is achieved only by using the superstrate layer that has been made by the FSS layer with square loop elements. At first, a wideband ACMA is designed to operate in x-band. In this step appropriate design of coupling aperture is of a great importance. Secondly, after the design of optimum superstrate layer by the FSS structure, it is added to the ACMA in order to increase both bandwidth and directivity.

16 March 2015 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HBHadi Bahrami
Hadi Bahrami
SMS. Abdollah Mirbozorgi
S. Abdollah Mirbozorgi
RAReza Ameli
Reza Ameli
LRLeslie Rusch
Leslie Rusch
Benoit GosselinBenoit Gosselin
Benoit Gosselin
Implanted antennas for implant-to-air data communications must be composed of material compatible with biological tissues. We design single and dual-polarization antennas for wireless ultra-wideband neural recording systems using an inhomogeneous multi-layer model of the human head. Antennas made from flexible materials are more easily adapted to implantation; we investigate both flexible and rigid materials and examine performance trade-offs. The proposed antennas are designed to operate in a frequency range of 2-11 GHz (having S11 below -10 dB) covering both the 2.45 GHz (ISM) band and the 3.1-10.6 GHz UWB band. Measurements confirm simulation results showing flexible antennas have little performance degradation due to bending effects (in terms of impedance matching). Our miniaturized flexible antennas are 12 mm×12 mm and 10 mm×9 mm for single- and dual-polarizations, respectively. Finally, a comparison is made of four implantable antennas covering the 2-11 GHz range: 1) rigid, single polarization, 2) rigid, dual polarization, 3) flexible, single polarization and 4) flexible, dual polarization. In all cases a rigid antenna is used outside the body, with an appropriate polarization. Several advantages were confirmed for dual polarization antennas: 1) smaller size, 2) lower sensitivity to angular misalignments, and 3) higher fidelity.

25 February 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SMS. Abdollah Mirbozorgi
S. Abdollah Mirbozorgi
HBHadi Bahrami
Hadi Bahrami
MSMohamad Sawan
Mohamad Sawan
Benoit GosselinBenoit Gosselin
Benoit Gosselin
This paper presents a novel resonance-based multicoil array structure to wirelessly charge or power up apparatus, like smart phones, computer mouses, smart animal research systems, or implanted medical devices. The proposed array consists of a novel multicoil inductive link, whose primary resonator is made of several identical coil elements connected in parallel and arranged in an array. Such a structure presents several key features compared to previous inductive coil arrays. The proposed approach can do the following: 1) deliver power with superior efficiency over longer separation distances; 2) naturally track the receiver position and localize transmitted power through nearby coil array elements without the need for complex control and detection circuitry; and 3) accommodate either short- or long-range power transmission applications simply by slightly modifying the receiver topology. The performance of the proposed structure is verified by measurement results. In a three-coil configuration, the prototype provides a power transfer efficiency (PTE) of 83.3% and a power delivered to the load (PDL) of 3.87 W for a separation distance below 1 cm, while in a four-coil configuration, it provides a PTE of 76% and a PDL of 115 mW for a separation distance of 4 cm.

31 March 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
ZYZheng Yong
Zheng Yong
WSWesley D. Sacher
Wesley D. Sacher
YHYing Huang
Ying Huang
JMJared C. Mikkelsen
Jared C. Mikkelsen
YYYisu Yang
Yisu Yang
JPJoyce K. S. Poon
Joyce K. S. Poon
We demonstrate U-shaped silicon PN junctions for energy efficient Mach-Zehnder modulators and ring modulators in the O-band. This type of junction has an improved modulation efficiency compared to existing PN junction geometries, has low losses, and supports high-speed operation. The U-shaped junctions were fabricated in an 8” silicon photonics platform, and they were incorporated in travelling-wave Mach-Zehnder modulators and microring modulators. For the high-bandwidth Mach-Zehnder modulator, the DC VπL at −0.5 V bias was 4.6 V·mm. It exhibited a 3dB bandwidth of 13 GHz, and eye patterns at up to 24 Gb/s were observed. A VπL as low as ~2.6 V·mm at a −0.5 V bias was measured in another device. The ring modulator tuning efficiency was 40 pm·V−1 between 0 V and −0.5 V bias. It had a 3-dB bandwidth of 13.5 GHz and open eye patterns at up to 13 Gb/s were measured. This type of PN junctions can be easily fabricated without extra masks and can be incorporated into generic silicon photonics platforms.

12 October 2015 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
SMS. Abdollah Mirbozorgi
S. Abdollah Mirbozorgi
HBHadi Bahrami
Hadi Bahrami
MSMohamad Sawan
Mohamad Sawan
LRLeslie Rusch
Leslie Rusch
Benoit GosselinBenoit Gosselin
Benoit Gosselin
We present a novel, fully-integrated, low-power full-duplex transceiver (FDT) to support high-density and bidirectional neural interfacing applications (high-channel count stimulating and recording) with asymmetric data rates: higher rates are required for recording (uplink signals) than stimulation (downlink signals). The transmitter (TX) and receiver (RX) share a single antenna to reduce implant size and complexity. The TX uses impulse radio ultra-wide band (IR-UWB) based on an edge combining approach, and the RX uses a novel 2.4-GHz on-off keying (OOK) receiver. Proper isolation (>20 dB) between the TX and RX path is implemented 1) by shaping the transmitted pulses to fall within the unregulated UWB spectrum (3.1-7 GHz), and 2) by space-efficient filtering (avoiding a circulator or diplexer) of the downlink OOK spectrum in the RX low-noise amplifier. The UWB 3.1-7 GHz transmitter can use either OOK or binary phase shift keying (BPSK) modulation schemes. The proposed FDT provides dual band 500-Mbps TX uplink data rate and 100 Mbps RX downlink data rate, and it is fully integrated into standard TSMC 0.18- μm CMOS within a total size of 0.8 mm 2 . The total measured power consumption is 10.4 mW in full duplex mode (5 mW at 100 Mbps for RX, and 5.4 mW at 500 Mbps or 10.8 pJ/bit for TX). Additionally, a 3-coil inductive link along with on-chip power management circuits allows to powering up the implantable transceiver wirelessly by delivering 25 mW extracted from a 13.56-MHz carrier signal, at a total efficiency of 41.6%.