16 November 2020 in Optics Express
Quantitative phase microscopy (QPM) is a label-free technique that enables monitoring of morphological changes at the subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth quantitative phase imaging using partially spatially coherent digital holographic microscopy (PSC-DHM) assisted with a deep neural network. The PSC source synthesized to improve the spatial sensitivity of the reconstructed phase map from the interferometric images. Further, compatible generative adversarial network (GAN) is used and trained with paired low-resolution (LR) and high-resolution (HR) datasets acquired from the PSC-DHM system. The training of the network is performed on two different types of samples, i.e. mostly homogenous human red blood cells (RBC), and on highly heterogeneous macrophages. The performance is evaluated by predicting the HR images from the datasets captured with a low NA lens and compared with the actual HR phase images. An improvement of 9× in the space-bandwidth product is demonstrated for both RBC and macrophages datasets. We believe that the PSC-DHM + GAN approach would be applicable in single-shot label free tissue imaging, disease classification and other high-resolution tomography applications by utilizing the longitudinal spatial coherence properties of the light source.
16 May 2023 in Applied Optics
Multispectral quantitative phase imaging (MS-QPI) is a high-contrast label-free technique for morphological imaging of the specimens. The aim of the present study is to extract spectral dependent quantitative information in single-shot using a highly spatially sensitive digital holographic microscope assisted by a deep neural network. There are three different wavelengths used in our method: λ=532, 633, and 808 nm. The first step is to get the interferometric data for each wavelength. The acquired datasets are used to train a generative adversarial network to generate multispectral (MS) quantitative phase maps from a single input interferogram. The network was trained and validated on two different samples: the optical waveguide and MG63 osteosarcoma cells. Validation of the present approach is performed by comparing the predicted MS phase maps with numerically reconstructed (FT+TIE) phase maps and quantifying with different image quality assessment metrices.
6 July 2024 in F&S Science
Objective: To demonstrate nanoscale motion tracing of spermatozoa and present analysis of the motion traces to characterize the consistency of motion of spermatozoa as a complement to progressive motility analysis. Design: Anonymized sperm samples were videographed under a quantitative phase microscope, followed by generating and analyzing superresolution motion traces of individual spermatozoa. Setting: Not applicable. Patient(s): Centrifuged human sperm samples. Intervention(s): Not applicable. Main Outcome Measure(s): Precision of motion trace of individual sperms, presence of a helical pattern in the motion trace, mean and standard deviations of helical periods and radii of sperm motion traces, speed of progression. Result(s): Spatially sensitive quantitative phase imaging with a superresolution computational technique MUltiple SIgnal Classification ALgorithm allowed achieving motion precision of 340 nm using x 10, 0.25 numerical aperture lens whereas the diffraction-limited resolution at this setting was 1,320 nm. The motion traces thus derived facilitated new kinematic features of sperm, namely the statistics of helix period and radii per sperm. Through the analysis, 47 sperms with a speed > 25 m m/s were randomly selected from the same healthy donor semen sample, it is seen that the kinematic features did not correlate with the speed of the sperms. In addition, it is noted that spermatozoa may experience changes in the periodicity and radius of the helical path over time. Further, some very fast sperms (e.g., > 70 m m/s) may demonstrate irregular motion and need further investigation. Presented computational analysis can be used directly for sperm samples from both fertility patients with normal and abnormal sperm cell conditions. We note that MUltiple SIgnal Classification ALgorithm is an image analysis technique that may vaguely fall under the machine learning category, but the conventional metrics for reporting found in Enhancing the QUAlity and Transparency Of health Research network do not apply. Alternative suitable metrics are reported, and bias is avoided through random selection of regions for analysis. Detailed methods are included for reproducibility. Conclusion(s): Kinematic features derived from nanoscale motion traces of spermatozoa contain information complementary to the speed of the sperms, allowing further distinction among the progressively motile sperms. Some highly progressive spermatozoa may have irregular motion patterns, and whether irregularity of motion indicates poor quality regarding artificial insemination needs further investigation. The presented technique can be generalized for sperm analysis for a variety of fertility conditions. (c) 2024 by American Society for Reproductive Medicine.
10 January 2026 in Optics and Lasers in Engineering
15 July 2025 in Optics and Lasers in Engineering
21 August 2025 in Optics & Laser Technology