Haizhou Liu

Haizhou Liu

Auto-generated profile, based on publicly available information

Haizhou Liu

The Research Center for Medical AI, Shenzhen Institute of Advanced Technology Chinese Academy of Sciences, No. 1068 Xueyuan Avenue, Nanshan District, Shenzhen, Shenzhen, Guangdong, 518055, CHINA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2023 in Engineering Fracture Mechanics
Verified
Journal Article
Closed access
HLHaizhou Liu
Haizhou Liu
FHFrançois Hild
François Hild

21 August 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
HJHeng Jiang
Heng Jiang
QZQiyang Zhang
Qiyang Zhang
YHYingying Hu
Yingying Hu
YJYuxi Jin
Yuxi Jin
HLHaizhou Liu
Haizhou Liu
ZHZhanli Hu
Zhanli Hu
Objective . Reconstructing high-quality images from corrupted measurements remains a fundamental challenge in medical imaging. Recently, deep unrolling (DUN) methods have emerged as a promising solution, combining the interpretability of traditional iterative algorithms with the powerful representation capabilities of deep learning. However, their performance is often limited by weak information flow between iterative stages and a constrained ability to capture global features across stages-limitations that tend to worsen as the number of iterations increases. Approach . In this work, we propose a memory-enhanced (ME) and multi-domain learning-based DUN network for interpretable, high-fidelity medical image reconstruction. First, a ME module is designed to adaptively integrate historical outputs across stages, reducing information loss. Second, we introduce a cross-stage spatial-domain learning transformer (CS-SLFormer) to extract both local and non-local features within and across stages, improving reconstruction performance. Finally, a frequency-domain consistency learning module ensures alignment between reconstructed and ground truth images in the frequency domain, recovering fine image details. Main results . Comprehensive experiments evaluated on three representative medical imaging modalities (positron emission tomography (PET), magnetic resonance imaging, and computed tomography) show that the proposed method consistently outperforms state-of-the-art approaches in both quantitative metrics and visual quality. Specifically, our method achieved a peak signal-to-noise of 37.835 dB and an structural similarity index of 0.970 in 1 % dose PET reconstruction. Significance . This study expands the use of model-driven deep learning in medical imaging, demonstrating the potential of ME DUN frameworks for high-quality reconstructions.

27 May 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HLHaizhou Liu
Haizhou Liu
YZYijia Zheng
Yijia Zheng
ZLZhou Liu
Zhou Liu
YJYuxi Jin
Yuxi Jin
ZLZhihua Li
Zhihua Li
ZHZhanli Hu
Zhanli Hu
Physiological and external motion cause inter-frame misalignment in chemical exchange saturation transfer magnetic resonance imaging (CEST-MRI), thereby compromising quantitative accuracy. In CEST-MRI, saturation effects induce intensity variations, resulting in motion-intensity coupling that makes registration particularly challenging. To address this issue, we extend the finite element digital image correlation (FE-DIC) framework by introducing an alternating correction strategy that iteratively refines both motion and intensity estimation. Unlike conventional FE-DIC approaches that assume intensity constancy, the proposed method incorporates mechanical regularization to suppress non-physical deformations, alongside intensity correction to compensate for reference-target contrast discrepancies. This mutual reinforcement enables progressively improved registration across the CEST sequence. The robustness and effectiveness of the method were evaluated on three datasets. In simulated liver data, it maintains RMSE within 0.4 pixels, reducing error by 0.5 pixels compared to RPCA&PCA (a PCA-based synthetic reference generation method for CEST registration). On clinical brain and pig cardiac data, it achieves average SSIM of 0.83, outperforming RPCA&PCA by 0.03 and surpassing CNN-based registration (e.g., AirLab) by 0.10. The consistent results across datasets highlight its generalizability, making it a promising tool for metabolic quantification in clinical and research settings.