Mohd Imran Yusof

Mohd Imran Yusof

Auto-generated profile, based on publicly available information

Mohd Imran Yusof

Department of Orthopaedic, School of Medical Sciences, Universiti Sains Malaysia, Health Campus, Kota Bharu, Malaysia

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Singapore Medical Journal
Verified
Journal Article
Closed access
JJJ Johari
J Johari
MSMa Sharifudin
Ma Sharifudin
ARA Ab Rahman
A Ab Rahman
AOAs Omar
As Omar
AAAt Abdullah
At Abdullah
MYMi Yusof
Mi Yusof
Formed in 1959, the Singapore Medical Association (SMA) is the national medical organisation representing the majority of medical practitioners in both the public and private sectors

1 April 2006 in Spine
Verified
Journal Article
Closed access
MYMohd Imran Yusof
Mohd Imran Yusof
LMLiau Kai Ming
Liau Kai Ming
MAMohd Shafie Abdullah
Mohd Shafie Abdullah
AYAbdul Halim Yusof
Abdul Halim Yusof
The cervical pedicle diameter size differs between Asians and non-Asians. The authors studied the transverse pedicle diameter of the C2-C7 of the cervical spine in a Malaysian population using computerized tomography (CT) measurements. The transverse diameter of the pedicle is the determinant of the feasibility of this technique because the sagittal diameter of the pedicle has been wider than the transverse pedicle diameter. To study the average transverse pedicle diameter of the cervical spine in a Malaysian population, and evaluate the feasibility and safety of pedicle screw fixation in these patients. Cervical transpedicular screw fixation has been safe and is most probably going to be the gold standard for cervical spine fixation. However, its use in the Asian population should be considered cautiously because our cervical pedicle diameter may not be adequate to accommodate the standard pedicle screw size, which can be dangerous because there are vital structures located adjacent to the pedicles. The measurements of the cervical pedicles were performed on CT images using its measurement tools. CT cutting was made at 2.5-mm intervals. The pedicle transverse diameters were defined as the most outer diameter of the pedicle, taken perpendicular to the axis of the pedicle and measured in millimeters up to 0.1 mm. The mean transverse diameters of the cervical pedicle of C2, C3, C4, C5, C6, and C7 in males were 5.4, 5.2, 5.1, 5.2, 5.5, and 6.5 mm, respectively, and ranged between 5.1 and 6.5 mm. In females, the mean transverse diameter of the cervical pedicle of C2, C3, C4, C5, C6, and C7 were 5.0, 4.6, 4.7, 4.9, 5.2, and 5.6 mm, respectively, and ranged between 4.6 and 5.6 mm. If the minimum transverse diameter required is 5.0 mm for 3.5-mm screw insertion, about 4.2% to 54.2% (male) of pedicles at different levels and 6.7% to 73.3% (females) of patients cannot have fixation with a 3.5-mm screw using this technique. Transpedicular screw fixation for the cervical spine must not be attempted in the Malaysian population before the exact pedicle diameters are known.Therefore, preoperative CT evaluation is a must before transpedicular fixation is performed, especially in female patients. Because the margin for mistake is very narrow, it is best avoided in upper cervical spines.

1 June 2010 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
HCHun Guan Chuah
Hun Guan Chuah
IRInzarulfaisham Abd Rahim
Inzarulfaisham Abd Rahim
MYMohd Imran Yusof
Mohd Imran Yusof
The stress shielding effect is an event in which the replacement implant limits the load transferred to bone and the ineffective stress in the vertebrae causes bony growth to cease. In the present study, a 3D finite element L4–L5 model was developed and subjected to a 1200 N compression preload. Five groups of muscle forces were applied on L4 under flexion–extension, lateral bending and axial rotation. Topology optimisation was employed for reducing the stress shielding effect by removing the ineffective material from the design domain. The optimised design was designed with polyaryletheretherketone (PEEK) titanium and cortical materials to encounter the shielding response. The stress responses show that the new design increased the stress magnitude by at least 17.10, 18.11 and 18.43% in 4 Nm of flexion–extension, lateral bending and axial rotation, respectively. In conclusion, the material factor did not significantly alter the stress magnitude, but volume was the key factor in reducing the stress shielding effect.

1 July 2006 in Spine
Verified
Journal Article
Closed access
KLKai Ming Liau
Kai Ming Liau
MYMohd Imran Yusof
Mohd Imran Yusof
MAMohd Shafie Abdullah
Mohd Shafie Abdullah
SASarimah Abdullah
Sarimah Abdullah
AYAbdul Halim Yusof
Abdul Halim Yusof
A cross-sectional study of thoracic pedicle morphometry (T1-T12) of 180 Malaysian Malay patients obtained from computed tomographic scan. To determine the safety margin in the placement of thoracic transpedicular screw in the Malay population. Previous studies have shown a significantly smaller thoracic pedicular parameters in Asians compared with whites. The safety margin in the placement of thoracic transpedicular screw in our population therefore needs to be defined. T1-T12 vertebral pedicles were studied in 180 Malay ethnic patients (age range, 18-80 years). The following parameters were studied: transverse outer pedicle diameter, transverse inner pedicle diameter, transverse pedicle angle, chord length, pedicle length, and pedicle cortical thickness. The data obtained were statistically analyzed using Student's t test and ANOVA test. Female patients have significantly smaller dimensions in most of the parameters measured compared with male patients. However, no significant difference was found between age groups. Transverse outer pedicle diameter were widest at T1 (male, 8.42 mm; female, 7.56 mm) and narrowest at T4 (male, 4.56 mm; female, 3.95 mm). Pedicle diameters of less than 5.5 mm were commonly seen at T4 followed by T5, T6, T7, T8, and T9. A significant percentage of patients have an outer diameter of less than 4.5 mm from T4-T7. The medial cortices were 50% thicker than the lateral cortices at most levels. Chord lengths were maximum at T8 and minimum at T1. Transverse pedicle angle were widest at T1 and less than 5 degrees from T7-T12. The results suggest that the current pedicle screw system is not suitable for the majority of Malay population, especially at midthoracic level. The smaller pedicle measurements in Malays may be attributed to their shorter body built compared with whites.

1 February 2016 in Nitric Oxide
Verified
Journal Article
Closed access
SMSiti Safiah Mokhtar
Siti Safiah Mokhtar
PVPaul M. Vanhoutte
Paul M. Vanhoutte
SLSusan Wai Sum Leung
Susan Wai Sum Leung
MYMohd Imran Yusof
Mohd Imran Yusof
WSWan Azman Wan Sulaiman
Wan Azman Wan Sulaiman
ARAida Hanum Ghulam Rasool
Aida Hanum Ghulam Rasool

1 January 2010
Verified
Journal Article
Closed access
JHJ Hasnan
J Hasnan
MYM I Yusof
M I Yusof
TDT D Damitri
T D Damitri
AFA R Faridah
A R Faridah
AAA S Adenan
A S Adenan
TNT H Norbaini
T H Norbaini