Jonghyun Park

Jonghyun Park

Auto-generated profile, based on publicly available information

Jonghyun Park

Samsung Research, Samsung Electronics, Seoul, Seocho, South Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
JLJoonnyong Lee
Joonnyong Lee
SSSukkyu Sun
Sukkyu Sun
SYSeung Man Yang
Seung Man Yang
JSJangjay Sohn
Jangjay Sohn
JPJonghyun Park
Jonghyun Park
HKHee Chan Kim
Hee Chan Kim
Photoplethysmography (PPG) has become ubiquitous with the development of smart watches and the mobile healthcare market. However, PPG is vulnerable to various types of noises that are ever present in uncontrolled environments, and the key to obtaining meaningful signals depends on successful denoising of PPG. In this context, algorithms have been developed to denoise PPG, but many were validated in controlled settings or are reliant on multiple steps that must all work correctly. This paper proposes a novel PPG denoising algorithm based on bidirectional recurrent denoising auto-encoder (BRDAE) that requires minimal pre-processing steps and have the benefit of waveform feature accentuation beyond simple denoising. The BRDAE was trained and validated on a dataset with artificially augmented noise, and was tested on a large open database of PPG signals collected from patients enrolled in intensive care units as well as from PPG data collected intermittently during the daily routine of nine subjects over 24 h. Denoising with the trained BRDAE improved signal-to-noise ratio of the noise-augmented data by 7.9 dB during validation. In the test datasets, the denoised PPG showed statistically significant improvement in heart rate detection as compared with the original PPG in terms of correlation to reference and root-mean-squared error. These results indicate that the proposed method is an effective solution for denoising the PPG signal, and promises values beyond traditional denoising by providing PPG feature accentuation for pulse waveform analysis.

18 June 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JLJoonnyong Lee
Joonnyong Lee
JSJangjay Sohn
Jangjay Sohn
JPJonghyun Park
Jonghyun Park
SYSeungMan Yang
SeungMan Yang
SLSaram Lee
Saram Lee
HKHee Chan Kim
Hee Chan Kim
Non-invasive continuous blood pressure monitors are of great interest to the medical community due to their value in hypertension management. Recently, studies have shown the potential of pulse pressure as a therapeutic target for hypertension, but not enough attention has been given to non-invasive continuous monitoring of pulse pressure. Although accurate pulse pressure estimation can be of direct value to hypertension management and indirectly to the estimation of systolic blood pressure, as it is the sum of pulse pressure and diastolic blood pressure, only a few inadequate methods of pulse pressure estimation have been proposed. We present a novel, non-invasive blood pressure and pulse pressure estimation method based on pulse transit time and pre-ejection period. Pre-ejection period and pulse transit time were measured non-invasively using electrocardiogram, seismocardiogram, and photoplethysmogram measured from the torso. The proposed method used the 2-element Windkessel model to model pulse pressure with the ratio of stroke volume, approximated by pre-ejection period, and arterial compliance, estimated by pulse transit time. Diastolic blood pressure was estimated using pulse transit time, and systolic blood pressure was estimated as the sum of the two estimates. The estimation method was verified in 11 subjects in two separate conditions with induced cardiovascular response and the results were compared against a reference measurement and values obtained from a previously proposed method. The proposed method yielded high agreement with the reference (pulse pressure correlation with reference R ≥ 0.927, diastolic blood pressure correlation with reference R ≥ 0.854, systolic blood pressure correlation with reference R ≥ 0.914) and high estimation accuracy in pulse pressure (mean root-mean-squared error ≤ 3.46 mmHg) and blood pressure (mean root-mean-squared error ≤ 6.31 mmHg for diastolic blood pressure and ≤ 8.41 mmHg for systolic blood pressure) over a wide range of hemodynamic changes. The proposed pulse pressure estimation method provides accurate estimates in situations with and without significant changes in stroke volume. The proposed method improves upon the currently available systolic blood pressure estimation methods by providing accurate pulse pressure estimates.

17 April 2024 in IEEE Access
Verified
Journal Article
Open access
JPJonghyun Park
Jonghyun Park
SYSeungman Yang
Seungman Yang
GCGihsung Chung
Gihsung Chung
IZIvo Junior Leal Zanghettin
Ivo Junior Leal Zanghettin
JHJonghee Han
Jonghee Han
As an increasing number of people suffer from sleep disorders, such as insomnia or sleep apnea, sleep monitoring and management using consumer devices have gained increasing attention from research communities. As sleep quality is closely related to sleep structure based on hypnograms, the classification of sleep stages over the course of the night is important for accurate sleep monitoring. We present sleep stage classification using a smartphone equipped with ultra-wideband (UWB) radar. We focused on the development of easily accessible sleep monitoring system for the general population by placing the smartphone on a table near a bed, which is commonly used during sleep. We collected 509 nights of UWB radar and nocturnal in-laboratory polysomnography (PSG) data from various participants, including patients with apnea, using a customized Samsung Galaxy smartphone with a UWB radar chip placed on a table near the bed. A combination of 1D convolutional neural network and transformer architecture was proposed in this study, and a domain adaptation technique was applied to train the model with both large-scale respiratory signals from open database PSGs and UWB radar data to boost the performance by overcoming the lack of UWB radar data. With 5-fold validation, an epoch-by-epoch comparison between the predicted and expert-annotated four sleep stages (Wake, REM sleep, light sleep, and deep sleep) resulted in 0.76 of accuracy and 0.64 of Cohen’s kappa. This study demonstrated that sleep stages can be monitored with substantial accuracy by simply placing a smartphone on a bedtable, making it highly usable and reliable in real use cases.

1 January 2012 in IEICE Transactions on Information and Systems
Verified
Journal Article
Open access
JPJonghyun Park
Jonghyun Park
SPSoonyoung Park
Soonyoung Park
WCWanhyun Cho
Wanhyun Cho


22 December 2008 in Canadian Journal of Electrical and Computer Engineering
Verified
Journal Article
Closed access
JPJonghyun Park
Jonghyun Park
Gueesang LeeGueesang Lee
Gueesang Lee
In this paper, a new method for detecting text regions in natural scene images is presented. The proposed algorithm is based on the segmentation of objects in a scene, followed by the identification of text objects by a support vector machine (SVM). First, to segment objects in the scene, the input image is separated into chromatic and achromatic regions according to the distribution of red, green and blue (RGB) elements, and different clustering algorithms are applied. Second, each object is transformed into the wavelet domain for multi-resolution analysis, and moment features of the wavelet coefficients are used in the SVM for the classification of text objects. The proposed approach provides robustness to non-uniform illumination by using different clustering algorithms according to the characteristics of the colour components in the segmentation. Also, moment features, used for classification, are invariant to the size, direction, shape and other properties of texts. Experimental results demonstrate the effectiveness of this approach.