Jian Li

Jian Li

Auto-generated profile, based on publicly available information

Jian Li

Department of Cardiology Chinese People's Liberation Army General Hospital Beijing China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
YFYong-Yan Fan
Yong-Yan Fan
YLYanguang Li
Yanguang Li
JLJian Li
Jian Li
WCWen-Kun Cheng
Wen-Kun Cheng
ZSZhao-Liang Shan
Zhao-Liang Shan
YGYu-Tao Guo
Yu-Tao Guo
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. The asymptomatic nature and paroxysmal frequency of AF lead to suboptimal early detection. A novel technology, photoplethysmography (PPG), has been developed for AF screening. However, there has been limited validation of smartphone and smart band applications with PPG compared to 12-lead electrocardiograms (ECG). Objective: We investigated the feasibility and accuracy of a smartphone- and smart band-based algorithm (PRO AF PPG) for AF detection using pulse data measured by PPG. Methods: One hundred twelve consecutive inpatients were recruited from the Chinese PLA General Hospital from 15 March to 1 April 2018. Participants were simultaneously tested with smartphones (HUAWEI Mate 9, HUAWEI Honor 7X), smart bands (HUAWEI Band 2), and 12-lead ECG for 3 minutes. Results: One hundred eight patients (56 with normal sinus rhythm, 52 with persistent AF) were enrolled in the final analysis after excluding 4 patients with unclear cardiac rhythms. The corresponding sensitivity and specificity of the smart band PPG were 95.36% (95% confidential interval, CI 92.00-97.40%) and 99.70% (95% CI 98.08-99.98%), respectively. The positive predictive value of the smart band PPG was 99.63% (95% CI 97.61-99.98%), the negative predictive value was 96.24% (95% CI 93.50-97.90%), and the accuracy was 97.72% (95% CI 96.11-98.70%). Moreover, the diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of smartphones with PPG for AF detection were over 94%. There was no significant difference after further statistical analysis of the results from the different smart devices compared with the gold-standard ECG (P=.999). Conclusions: The algorithm based on smartphones and smart bands with PPG demonstrated good performance in detecting AF and may represent a convenient tool for AF detection in at-risk individuals, allowing widespread screening of AF in the population. Clinical Trial: The present study was registered in the Chinese Clinical Trial Registry, International Clinical Trials Registry Platform of the World Health Organization (ChiCTR-OOC-17014138).

28 June 2018 in JMIR Preprints
Verified
Preprint
Open access
YFYong-Yan Fan
Yong-Yan Fan
YLYanguang Li
Yanguang Li
JLJian Li
Jian Li
WCWen-Kun Cheng
Wen-Kun Cheng
ZSZhao-Liang Shan
Zhao-Liang Shan
YGYu-Tao Guo
Yu-Tao Guo
BACKGROUND Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. The asymptomatic nature and paroxysmal frequency of AF lead to suboptimal early detection. A novel technology, photoplethysmography (PPG), has been developed for AF screening. However, there has been limited validation of mobile phone and smart band apps with PPG compared to 12-lead electrocardiograms (ECG). OBJECTIVE We investigated the feasibility and accuracy of a mobile phone and smart band for AF detection using pulse data measured by PPG. METHODS A total of 112 consecutive inpatients were recruited from the Chinese PLA General Hospital from March 15 to April 1, 2018. Participants were simultaneously tested with mobile phones (HUAWEI Mate 9, HUAWEI Honor 7X), smart bands (HUAWEI Band 2), and 12-lead ECG for 3 minutes. RESULTS In all, 108 patients (56 with normal sinus rhythm, 52 with persistent AF) were enrolled in the final analysis after excluding four patients with unclear cardiac rhythms. The corresponding sensitivity and specificity of the smart band PPG were 95.36% (95% CI 92.00%-97.40%) and 99.70% (95% CI 98.08%-99.98%), respectively. The positive predictive value of the smart band PPG was 99.63% (95% CI 97.61%-99.98%), the negative predictive value was 96.24% (95% CI 93.50%-97.90%), and the accuracy was 97.72% (95% CI 96.11%-98.70%). Moreover, the diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of mobile phones with PPG for AF detection were over 94%. There was no significant difference after further statistical analysis of the results from the different smart devices compared with the gold-standard ECG (P>.99). CONCLUSIONS The algorithm based on mobile phones and smart bands with PPG demonstrated good performance in detecting AF and may represent a convenient tool for AF detection in at-risk individuals, allowing widespread screening of AF in the population. CLINICALTRIAL Chinese Clinical Trial Registry ChiCTR-OOC-17014138; http://www.chictr.org.cn/showproj.aspx?proj=24191 (Archived by WebCite at http://www.webcitation/76WXknvE6)