Pierre Laguillaumie

Pierre Laguillaumie

Auto-generated profile, based on publicly available information

Pierre Laguillaumie

PPrime Institute / Poitiers University

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
ANAlexis Nez
Alexis Nez
LFLaetitia FRADET
Laetitia FRADET
PLPierre Laguillaumie
Pierre Laguillaumie
TMTony Monnet
Tony Monnet
PLPatrick Lacouture
Patrick Lacouture
In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of these applications, a highly accurate estimation of the acceleration is required. Many authors suggest improving result accuracy by updating sensor calibration parameters. Yet navigating the vast array of published calibration methods can be confusing. In this context, this paper reviews and evaluates the main measurement models and calibration methods. It also gives useful recommendations for better selection of a calibration process with regard to a specific application, which boils down to a compromise between accuracy, required installation, algorithm complexity, and time.

16 January 2019 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Open access
HFH. Fischer
H. Fischer
MVM. Vulliez
M. Vulliez
PLP. Laguillaumie
P. Laguillaumie
PVP. Vulliez
P. Vulliez
JGJ. P. Gazeau
J. P. Gazeau
This paper presents the challenges met in the development of a new framework for multiaxis and multirobot control. The increasing demand for multirobot collaboration and robotic assistance, both in industry and service applications, has raised the level of interactions between robots and humans in a shared environment with real-time constraints. Some scientific and technological issues need to be unlocked to ensure safe human-robot interactions: to guarantee the response time during the robot perception-action process, to cope with dynamic interactions with the robot environment, to secure the collaborations between several machines and humans, and to improve the integration of the robots at home and in open zones of production lines. The specifications of a new hardware and software framework are set with respect to these observations. The framework will meet complex research and industrial issues for the future of multiaxis and multirobot control. Before introducing our approach, a brief survey of existing frameworks and robotic middleware is given. The foundations of our approach are based on the following requirements: the framework must be real time, transferable, maintainable, and multimanufacturer. The framework design has also to guarantee the robustness of the machine interactions in a dynamic and collaborative environment. To evaluate the feasibility of our design strategy and assess its performance, we have developed mechatronic devices with a high level of human-machine collaboration. This paper outlines two robotic applications which require multirobot real-time synchronization and are based on the proposed framework. A temporal analysis demonstrates its robustness for multiaxis and multirobot control.

3 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LPLeonie Pacher
Leonie Pacher
CCChristian Chatellier
Christian Chatellier
PLPierre Laguillaumie
Pierre Laguillaumie
RVRodolphe Vauzelle
Rodolphe Vauzelle
LFLaetitia FRADET
Laetitia FRADET
A pre-requisite for obtaining human movement kinematics from Inertial Measurement Units (IMUs) is to define the relative orientation between the IMU coordinate systems and that of the underlying segment: a step called sensor-to-segment (S2S) calibration. Many S2S calibration methods have been proposed in the literature for the lower-body segments. However, these methods were not compared in a single study and the methodology differences between the studies make an objective assessment of the proposed S2S methods impossible. The present study aims firstly to compare different S2S calibration methods of the lower limbs in terms of accuracy, repeatability, and usability, and secondly to specify the impact of the S2S calibration method on lower-body kinematics. In Experiment 1, two postures, eight active, and five passive movements, and the use of a device were tested to define lower-body segment axes. To isolate the effect of the S2S calibration methods from IMU measures, the IMU measure was mimicked using marker trajectories tracked by an optoelectronic system. The angles between the segment axes obtained with the S2S calibration methods and axes of reference based on an optoelectronic methodology were then compared during a study involving fifteen subjects. The results do not reveal unique methods, but enable some to be discarded in terms of angle error and repeatability. Following these results, scoring of the methods was proposed in order to help select the most suitable S2S calibration methods given experimental context or subject ability. In Experiment 2, three kinematics obtained with IMUs after S2S calibrations combining the best previous methods, and kinematics obtained with the reference, were compared through RMSE, correlation coefficients, and difference in range of motion during gait, running, and cycling on an ergocycle. The combination, which included only, standing and sitting postures showed significantly lower RMSE (p<0.01) and range of motion differences (p<0.01) in ankle abduction/adduction and plantar/dorsiflexion respectively, making this combination a good candidate for S2S calibration of the lower-body for non-pathological subjects.

22 September 2015
Verified
Book Chapter
Closed access
PDF file
PLP. Laguillaumie
P. Laguillaumie
Med amine LaribiMed amine Laribi
Med amine Laribi
PSP. Seguin
P. Seguin
PVP. Vulliez
P. Vulliez
ADA. Decatoire
A. Decatoire
Saïd ZeghloulSaïd Zeghloul
Saïd Zeghloul

4 July 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
BTBaptiste Toussaint--Malard
Baptiste Toussaint--Malard
FDFrédéric R. Danion
Frédéric R. Danion
CMCharlotte Le Mouel
Charlotte Le Mouel
ADArnaud Decatoire
Arnaud Decatoire
PLPierre Laguillaumie
Pierre Laguillaumie
RTROMAIN TISSERAND
ROMAIN TISSERAND
Upright postural control during movement relies on multisensory integration. Yet, the frequency-specific contribution of vision remains poorly characterized in virtual reality (VR). This study investigated how multi-sine visual stimulation amplitude delivered in VR influences standing postural responses. Fifteen healthy adults stood on a force plate wearing a VR headset. Visuo-postural coupling was assessed through coherence and gain analyses between a multi-sine signal (10 sinusoids, 0.12 to 1 Hz) oscillating a virtual environment in one of four amplitudes (0.5, 1, 2, 4 degrees peak-to-peak) and the anteroposterior whole-body angle. All amplitudes elicited measurable postural responses. Increasing amplitude significantly increased postural oscillation and tended to increase coherence, while gain significantly decreased. These results are consistent with a nonlinear control system. The 2 degrees amplitude elicited the largest gain with significant coherence across all stimulated frequencies, suggesting it is suitable for studying visual contributions to postural control during movement execution.

7 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MSMathias Samson
Mathias Samson
RGRaphael Guignabel
Raphael Guignabel
SKShigetada Kudo
Shigetada Kudo
TTTakaaki Tsunokawa
Takaaki Tsunokawa
YNYusaku Nakazono
Yusaku Nakazono
AEAntoine Eon
Antoine Eon
We evaluated an unsteady Reynolds-averaged Navier–Stokes (URANS) volume-of-fluid (VOF) k–ω SST CFD model against dynamic pressure measurements from 24 piezoresistive sensors mounted on a robotic forearm–hand model of front crawl swimming. Nineteen kinematic conditions yielded 456 sensor–condition signal-to-signal comparisons stratified by surface, segment and angular window. Agreement was assessed using Pearson’s r, Lin’s concordance correlation coefficient (CCC), root mean square error (RMSE), normalised RMSE (NRMSE) and bias. Experimental repeatability was high (median NRMSErep = 5.4%), providing a benchmark against which CFD–experiment discrepancies were assessed.Agreement was strongly surface-dependent. Palmar agreement was highest on the hand (r = 0.697, CCC = 0.629, bias = −14 Pa) and lower on the forearm (r = 0.507, CCC = 0.430, bias = −15 Pa). Across conditions, agreement showed a strong descriptive association with the kinematic dimensionless ratio Vc/(Lω), higher at lower values, degrading as the ratio approached unity. A complementary analysis (multiple regression, partial correlation, additive-noise simulation) associated this dependence predominantly with the kinematic regime rather than a signal-to-noise artefact. Dorsal pressures were poorly reproduced, particularly on the forearm (r = 0.083): mean bias was +298 Pa (hand) and +255 Pa (forearm), with systematic underestimation of suction (> 90% of dorsal pairs) and phase-dependent disagreement at 40°–90°.These results support cautious use of the URANS–VOF model for palmar pressure timing analyses within the tested kinematic domain, but not for spatial interpolation across the segment or net-force estimation involving dorsal suction. This signal-to-signal framework is transferable to CFD evaluations in aquatic biomechanics.