Kazuya Sase

Kazuya Sase

Auto-generated profile, based on publicly available information

Kazuya Sase

Department of Mechanical Engineering and Intelligent Systems, Tohoku Gakuin University, Sendai, Miyagi, Japan

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2023 in IEEE Transactions on Haptics
Verified
Journal Article
Closed access
NMNatsumi Morita
Natsumi Morita
AIAkio Ichijo
Akio Ichijo
MKMasashi Konyo
Masashi Konyo
HKHaruki Kato
Haruki Kato
KSKazuya Sase
Kazuya Sase
STSatoshi Tadokoro
Satoshi Tadokoro
A high-resolution haptic display that reproduces tactile distribution information on the contact surface between a finger and an object realizes the presentation of the softness of the object and the magnitude and direction of the applied force. In this paper, we developed a 32-channel suction haptic display that can reproduce tactile distribution on fingertips with high resolution. The device is wearable, compact, and lightweight, thanks to the absence of actuators on the finger. A FE analysis of the skin deformation confirmed that the suction stimulus interfered less with adjacent stimuli in the skin than when pressing with positive pressure, thus allowing more precise control of local tactile stimuli. The optimal layout with the least error was selected from three configurations dividing 62 suction holes into 32 ports. The suction pressures were determined by calculating the pressure distribution by a real-time finite element simulation of the contact between the elastic object and the rigid finger. A discrimination experiment of softness with different Young's modulus and its JND investigation suggested that the higher resolution of the suction display improved the performance of the softness presentation compared to a 16-channel suction display previously developed by the authors.

5 May 2023 in International Journal of Automation Technology
Verified
Journal Article
Open access
SSSayaka Shibuya
Sayaka Shibuya
NSNoriyuki Shido
Noriyuki Shido
RSRyosuke Shirai
Ryosuke Shirai
KSKazuya Sase
Kazuya Sase
KEKoki Ebina
Koki Ebina
AKAtsushi Konno
Atsushi Konno
This study proposes simulation-based surgical navigation concept and describes the development of a laparoscopic surgical simulator that reflects the motion of surgical instruments in the real world. In the proposed simulation-based surgical navigation, movements of the surgical instruments are captured by a motion capture system, and the movements of the real surgical instruments are reflected in the movements of the virtual instruments in the simulation in real time. Contact of the virtual surgical instruments with organ model is detected based on the signed distance field (SDF) made around the organ model. The deformations of organs caused by contacts are calculated using dynamic finite element method (FEM). Using a cubic elastic object made of urethane resin, the accuracy of the calculation of the deformation was verified. The average error in the deformation verification experiments was within 1 mm. Simulations using hepato-biliary-pancreatic finite element (FE) models were performed, and computational costs of the simulation were validated. The time for one loop simulation with a hepato-biliary-pancreatic FE model of 3,225 elements and 1,663 nodes was 50 ms. The developed simulator can be applied to a simulation-based navigation system to update the states of organs in real time.

1 January 2020
Verified
Conference Paper
Closed access
XCXiaoshuai Chen
Xiaoshuai Chen
KSKazuya Sase
Kazuya Sase
TTTeppei Tsujita
Teppei Tsujita
AKAtsushi Konno
Atsushi Konno
Presenting correct reaction force is an important functional element of a haptic surgical simulator which is used to practice surgical techniques by novice surgeons. Particularly, in neurosurgeries, novice surgeons rely on the force felt at their hands in many situations. However, it is difficult to accurately calculate the deformation and reaction force of brain tissues in real-time because of the nonlinearity of the brain tissues. In this study, a simple numerical calculation method for nonlinear brain tissues is proposed. The simulation is constructed based on the finite element method, and the nonlinear characteristics of brain tissues are reproduced. When a force is applied to the brain parenchyma, the reaction force nonlinearly increases as the deformation proceeds. The phenomenon is reproduced by increasing a scale factor of the stiffness matrix as the von Mises stress of the element increases. To validate the proposed calculation method, experiments were performed using porcine brains. In experiments, the longitudinal cerebral fissure of the brain was retracted at 1 mm/s and 10 mm/s. Necessary parameters for the proposed calculation method were identified by using experimental data of 1 mm/s. By comparing the simulation results and experimental data of 10 mm/s with the same parameters, the validity and accuracy of the proposed nonlinear calculation method of brain tissue were proved.

26 August 2025 in Auris Nasus Larynx
Verified
Journal Article
Closed access
KYKaito Yamada
Kaito Yamada
MSMasanobu Suzuki
Masanobu Suzuki
KMKou Miyaji
Kou Miyaji
KSKazuya Sase
Kazuya Sase
KEKoki Ebina
Koki Ebina
AHAkihiro Homma
Akihiro Homma

2 March 2017
Verified
Conference Paper
Closed access
XCXiaoshuai Chen
Xiaoshuai Chen
KSKazuya Sase
Kazuya Sase
AKAtsushi Konno
Atsushi Konno
TTTeppei Tsujita
Teppei Tsujita
In this paper, a damage and fracture model of brain parenchyma is proposed for a haptic brain surgery simulation. It is assumed that microscopic damage begins by von Mises yield criterion, and the microscopic damage grows rate in proportion to volume strain. Tensile tests with two different strain rate were conducted using porcine brain parenchyma (tensile velocities: 0.1 (mm/s) and 1.0 (mm/s), mean length of specimens: 15 (mm)). Mechanical properties and proposed damage model parameters were identified by solving optimization problem with fitted curves of experimental data at 0.1 (mm/s). The proposed model and identified parameters were verified by comparing the simulation result and experimental data with tensile velocity of 1.0 (mm/s). A conventional damage model, simplified Lemaitre model, was implemented for comparison. Tensile simulations were performed with two models, proposed model and simplified Lemaitre model, with tensile velocity of 0.1 (mm/s). The simulation results were compared with the experimental result. It is confirmed that the proposed model well reproduce damage and fracture mechanics of brain parenchyma, while the simplified Lemaitre model could not well reproduce the ductility.

20 August 2024 in Journal of Robotics and Mechatronics
Verified
Journal Article
Open access
XCXiaoshuai Chen
Xiaoshuai Chen
TSTaro Shoji
Taro Shoji
RKRyosuke Kowatari
Ryosuke Kowatari
KEKoki Ebina
Koki Ebina
YKYoshifumi Kobayashi
Yoshifumi Kobayashi
AKAtsushi Konno
Atsushi Konno
In off-pump coronary artery bypass grafting (OPCAB), the coronary arteries are joined as the heart beats. This procedure requires high skill and experience to be performed reliably and quickly. Although training kits are commonly used for technical training, the inability of trainees to always be with experienced surgeons for guidance and to receive immediate evaluation remains problematic. To address this problem, a system that allows a single trainee to observe and quantitatively evaluate the procedures performed by an experienced surgeon is being developed. In this study, to analyze the differences between the motions of experienced and novice surgeons, Leap Motion was used to measure the hand motion of the vascular anastomosis performed by both surgeons using a training kit. Using the measured data, the features of the vascular anastomosis surgical techniques performed by experienced and novices were tested using the Mann–Whitney U test. In addition, a binary classification was performed using machine learning with these features. The binary classification results show that trainees can be classified as experts or novices with high accuracy using the developed system.