27 September 2023 in IEEE Access
This study proposes a deep transfer learning method using a deep convolutional neural network pre-trained with ImageNet for transient stability assessment. The procedure of deep transfer learning, incorporating the role and considerations of the transient stability assessment system, is suggested. The transient assessment system learns the relationship between the severity of disturbances and transient stability in the power system through the proposed training method. The severity of a disturbance based on the physical causal relationship of the angle stability is proposed to train and implement the transient stability assessment model. The power system state variables obtained from the phasor measurement unit are converted into the feature map described by the severity of a disturbance, enabling the training of transient stability characteristics of the power system to the deep convolutional neural network. The training dataset is constructed using the time-domain simulation on IEEE 39 and IEEE 118-bus benchmark power system models configured in MATLAB/Simulink. As a result of deep transfer learning, which involves training with freezing some of the convolutional layers of the pre-trained deep network, the most suitable model for transient stability assessment is selected among the pre-trained deep networks. The effectiveness of the proposed method is compared with other approaches using the confusion matrix, and the robustness against noise interference is also investigated.
7 February 2023 in Journal of Electrical Engineering & Technology
19 April 2022 in IEEE Transactions on Power Systems
This paper proposes a novel control strategy to improve the stability and performance of the linear feedback control (LC) by alleviating the nonlinearity of a synchronous generator (SG). This control strategy, Jacobian gain control (JGC), uses the Jacobian function (JF), which is the sensitivity between the power imbalance in an electrical power system (EPS) and the state variables of SGs, for control. The JFs composed of a combination of state variables of an SG were established by the Jacobian reflecting physical characteristics of SG control. An integrated controller, JGC, for the SG was constructed by applying the JFs to the models of the governor (GOV), excitation system (EX), and power system stabilizer (PSS), respectively. The effects of JGC were identified by frequency response analysis of a single machine infinite bus (SMIB) model. The comprehensive control performance and stability of JGC were verified through various case-by-case time-domain simulations on two-area and IEEE 39-bus system configured by MATLAB/Simulink.
1 May 2025 in IEEE Access
This study proposes a scheme for determining the loss of synchronism in synchronous generators based on the direct method, utilizing a single local speed measurement within a generator system. By employing individual machine energy functions, this approach establishes a theoretical foundation for determining synchronization thresholds from the perspective of a single generator. Building on this foundation, clear criteria are suggested for determining whether a generator remains stable. The feasibility of the proposed method is verified through its application to synchronous generators, considering a comprehensive setup environment for implementing the proposed algorithm. Case studies are conducted using time-domain simulations in MATLAB/Simulink on the IEEE 39-bus system with varying system inertia and the IEEE 118-bus system. These case studies evaluate the robustness of the proposed criteria and algorithm in determining out-of-step conditions from an energy conversion perspective, analyzing variations in system inertia, control system parameters, power system scale, and fault scenarios across benchmark systems. Furthermore, the performance of the proposed protection scheme is compared with previous studies, highlighting its advantages. By interpreting the loss of synchronism phenomenon using only local measurements from existing systems, the proposed scheme demonstrates robustness against changes in the characteristics of the connected power system. It also simplifies the detailed settings required for effective operation of the protection scheme.