Tomas Strömberg

Tomas Strömberg

Auto-generated profile, based on publicly available information

Tomas Strömberg

Department of Biomedical Engineering, Linköping University, Linköping, Sweden

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2020 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
HJHanna Jonasson
Hanna Jonasson
SBSara Bergstrand
Sara Bergstrand
IFIngemar Fredriksson
Ingemar Fredriksson
MLMarcus Larsson
Marcus Larsson
CÖCarl Johan Östgren
Carl Johan Östgren
TSTomas Strömberg
Tomas Strömberg
The objective of this study was to assess normative values for comprehensive forearm skin microcirculatory function: oxygen saturation, tissue fraction of red blood cells (RBCs), and speed-resolved perfusion. Furthermore, to examine the influence of age and sex on microcirculatory function. Measurements were performed using a noninvasive probe-based system, including diffuse reflectance spectroscopy and laser-Doppler flowmetry, yielding output data in absolute units. The study was conducted within the Swedish CArdioPulmonary BioImage Study (SCAPIS) and included 1,765 men and women aged 50–65 yr from the Linköping general population. Normative values are given at baseline, at the end of a 5-min occlusion of the brachial artery and during hyperemia after occlusion release. We found a consistent age distribution, in which the oldest individuals had the lowest peak oxygen saturation ( P < 0.001) and the highest baseline low-speed perfusion ( P < 0.001). Women had higher peak oxygen saturation ( P < 0.001), lower RBC tissue fraction, in general ( P < 0.001), lower baseline perfusion in all speed regions ( P = 0.01), and lower peak high-speed perfusion at hyperemia ( P < 0.001). The normative data can be used as reference values in future studies of disease-specific populations. The results show that age and sex are important aspects to consider in studies of microvascular function. Women and younger age were factors associated with higher peak oxygen saturation after ischemia. This is a novel parameter that reflects overall microcirculatory function associated with vascular dilation capacity. NEW & NOTEWORTHY This study expands experimental microcirculatory research to clinical use by providing normative values on microcirculatory function in a large population-based cohort. Women and younger age were factors associated with higher peak oxygen saturation after ischemia, which implies that age and sex are important aspects to consider in studies of microvascular function. This study is the first step toward using microcirculatory assessment as a tool to improve diagnosis, prognosis, and treatment in disease-specific populations.

1 September 2017 in Microvascular Research
Verified
Journal Article
Closed access
TSTomas Strömberg
Tomas Strömberg
FSFolke Sjöberg
Folke Sjöberg
SBSara Bergstrand
Sara Bergstrand

10 November 2021 in Skin Research and Technology
Verified
Journal Article
Open access
PDF file
IFIngemar Fredriksson
Ingemar Fredriksson
MLMarcus Larsson
Marcus Larsson
TSTomas Strömberg
Tomas Strömberg
FIFredrik Iredahl
Fredrik Iredahl
Background: Vasomotion is the spontaneous oscillation in vascular tone in the microcirculation and is believed to be a physiological mechanism facilitating the transport of blood gases and nutrients to and from tissues. So far, Laser Doppler flowmetry has constituted the gold standard for in vivo vasomotion analysis.Materials and methods: We applied vasomotion analysis to speed‐resolved perfusion, oxygen saturation, red blood cell tissue (RBC) tissue fraction, and average vessel diameter from five healthy individuals at rest measured by the newly developed Periflux 6000 EPOS system over 10 minutes. Magnitude scalogram and the time‐averaged wavelet spectra were divided into frequency intervals reflecting endothelial, neurogenic, myogenic, respiratory, and cardiac function.Results: Recurrent high‐intensity periods of the myogenic, neurogenic, and endothelial frequency intervals were found. The neurogenic activity was considerably more pronounced for the oxygen saturation, RBC tissue fraction, and vessel diameter signals, than for the perfusion signals. In a correlation analysis we found that changes in perfusion in the myogenic, neurogenic, and endothelial frequency intervals precede changes in the other signals. Furthermore, changes in average vessel diameter were in general negatively correlated to the other signals in the same frequency intervals, indicating the importance of capillary recruitment.Conclusion: We conclude that vasomotion can be observed in signals reflecting speed resolved perfusion, oxygen saturation, RBC tissue fraction, and vessel diameter. The new parameters enable new aspects of the microcirculation to be observed.

7 August 2017 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
MHMartin Hultman
Martin Hultman
IFIngemar Fredriksson
Ingemar Fredriksson
MLMarcus Larsson
Marcus Larsson
AAAtila Alvandpour
Atila Alvandpour
TSTomas Strömberg
Tomas Strömberg
A multiple exposure laser speckle contrast imaging (MELSCI) setup for visualizing blood perfusion was developed using a field programmable gate array (FPGA), connected to a 1000 frames per second (fps) 1‐megapixel camera sensor. Multiple exposure time images at 1, 2, 4, 8, 16, 32 and 64 milliseconds were calculated by cumulative summation of 64 consecutive snapshot images. The local contrast was calculated for all exposure times using regions of 4 × 4 pixels. Averaging of multiple contrast images from the 64‐millisecond acquisition was done to improve the signal‐to‐noise ratio. The results show that with an effective implementation of the algorithm on an FPGA, contrast images at all exposure times can be calculated in only 28 milliseconds. The algorithm was applied to data recorded during a 5 minutes finger occlusion. Expected contrast changes were found during occlusion and the following hyperemia in the occluded finger, while unprovoked fingers showed constant contrast during the experiment. The developed setup is capable of massive data processing on an FPGA that enables processing of MELSCI data in 15.6 fps (1000/64 milliseconds). It also leads to improved frame rates, enhanced image quality and enables the calculation of improved microcirculatory perfusion estimates compared to single exposure time systems.


11 September 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
HJHanna Jonasson
Hanna Jonasson
IFIngemar Fredriksson
Ingemar Fredriksson
MLMarcus Larsson
Marcus Larsson
TSTomas Strömberg
Tomas Strömberg
Laser Doppler flowmetry (LDF) can be used to measure perfusion [fraction of red blood cells (RBCs) times their average speed] in the microcirculation. Conventional LDF measures perfusion in arbitrary units, by calculating the first moment of the Doppler spectrum.1 By considering the complete distribution of Doppler frequencies and not only the first moment, a speed-resolved perfusion measure can be obtained. Using this approach typically involves a decomposition of the LDF photodetector power spectrum. Liebert et al.2 developed a calculation scheme based on light transport simulations where the scattering phase function anisotropy value of the medium was varied until the modeled and measured spectra matched. The calculations were evaluated in the single Doppler-shift regime using highly diluted milk flowing in tubes.3 No independent validation of the anisotropy value was performed. Later, this model was expanded to account for multiple Doppler shifts.4 However, evaluation measurements in the multiple Doppler-shift regimes using a flow phantom showed that it was not possible to estimate the speed distribution in detail due to system noise.