Milena Cerny

Milena Cerny

Auto-generated profile, based on publicly available information

Milena Cerny

Department of Radiology, Centre hospitalier de l'Université de Montréal (CHUM), Montréal, Québec, Canada

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in RadioGraphics
Verified
Journal Article
Closed access
RLRoxanne Labranche
Roxanne Labranche
GGGuillaume Gilbert
Guillaume Gilbert
MCMilena Cerny
Milena Cerny
KVKim-Nhien Vu
Kim-Nhien Vu
DSDenis Soulières
Denis Soulières
ATAn Tang
An Tang
This review describes MR imaging techniques for liver iron quantification and provides an overview of common causes, complications, and treatments of liver iron overload, with discussion of pitfalls and future directions in liver iron quantification. Iron overload is a systemic disorder and is either primary (genetic) or secondary (exogenous iron administration). Primary iron overload is most commonly associated with hereditary hemochromatosis and secondary iron overload with ineffective erythropoiesis (predominantly caused by β-thalassemia major and sickle cell disease) that requires long-term transfusion therapy, leading to transfusional hemosiderosis. Iron overload may lead to liver cirrhosis and hepatocellular carcinoma, in addition to cardiac and endocrine complications. The liver is one of the main iron storage organs and the first to show iron overload. Therefore, detection and quantification of liver iron overload are critical to initiate treatment and prevent complications. Liver biopsy was the historical reference standard for detection and quantification of liver iron content. Magnetic resonance (MR) imaging is now commonly used for liver iron quantification, including assessment of distribution, detection, grading, and monitoring of treatm...

1 July 2018 in Radiology
Verified
Journal Article
Closed access
MCMilena Cerny
Milena Cerny
CBCatherine Bergeron
Catherine Bergeron
JBJean-Sébastien Billiard
Jean-Sébastien Billiard
JMJessica Murphy-Lavallée
Jessica Murphy-Lavallée
DODamien Olivié
Damien Olivié
ATAn Tang
An Tang
LI-RADS major features have moderate to excellent specificity for HCC, except for arterial phase hyperenhancement. Ancillary features modify the final category in a substantial proportion of observations and increase sensitivity while preserving high specificity for the diagnosis of HCC. PurposeTo evaluate the performance of major features, ancillary features, and categories of Liver Imaging Reporting and Data System (LI-RADS) version 2014 at magnetic resonance (MR) imaging for the diagnosis of hepatocellular carcinoma (HCC).Materials and MethodsThis retrospective institutional review board–approved study included patients with liver MR imaging and at least one pathologically proved lesion. Between 2004 and 2016, 102 patients (275 observations including 113 HCCs) met inclusion criteria. Two radiologists independently assessed major and ancillary imaging features for each liver observation and assigned a LI-RADS category. Per-lesion estimates of diagnostic performance of major features, ancillary features, and LI-RADS categories were assessed by using generalized estimating equation models.ResultsMajor features (arterial phase hyperenhancement, washout, capsule, and threshold growth) had a sensitivity of 88.5%, 60.6%, 32.9%, and 41.6%, and a specificity of 18.6%, 84.8%, 98.8%, and 83.2% fo...

1 November 2018 in RadioGraphics
Verified
Journal Article
Closed access
MCMilena Cerny
Milena Cerny
VCVictoria Chernyak
Victoria Chernyak
DODamien Olivié
Damien Olivié
JBJean-Sébastien Billiard
Jean-Sébastien Billiard
JMJessica Murphy-Lavallée
Jessica Murphy-Lavallée
ATAn Tang
An Tang
The Liver Imaging Reporting and Data System (LI-RADS) standardizes performance of liver imaging in patients at risk for hepatocellular carcinoma (HCC) as well as interpretation and reporting of the results. Developed by experts in liver imaging and supported by the American College of Radiology, LI-RADS assigns to observations categories that reflect the relative probability of benignity, HCC, or other malignancy. While category assignment is based mainly on major imaging features, ancillary features may be applied to improve detection and characterization, increase confidence, or adjust LI-RADS categories. Ancillary features are classified as favoring malignancy in general, HCC in particular, or benignity. Those favoring malignancy in general or HCC in particular may be used to upgrade by a maximum of one category up to LR-4; those favoring benignity may be used to downgrade by a maximum of one category. If there are conflicting ancillary features (ie, one or more favoring malignancy and one or more favoring benignity), the category should not be adjusted. Ancillary features may be seen at diagnostic CT, MRI performed with extracellular agents, or MRI performed with hepatobiliary agents, with the exception of one ancillary feature assessed at US. This article focuses on LI-RADS version 2018 ancillary features seen at MRI. Specific topics include rules for ancillary feature application; definitions, rationale, and illustrations with clinical MRI examples; summary of evidence and diagnostic performance; pitfalls; and future directions. ©RSNA, 2018.

1 March 2019 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
EVEugene Vorontsov
Eugene Vorontsov
MCMilena Cerny
Milena Cerny
PRPhilippe Régnier
Philippe Régnier
LJLisa Di Jorio
Lisa Di Jorio
CPChristopher J. Pal
Christopher J. Pal
ATAn Tang
An Tang
Purpose To evaluate the performance, agreement, and efficiency of a fully convolutional network (FCN) for liver lesion detection and segmentation at CT examinations in patients with colorectal liver metastases (CLMs). Materials and Methods This retrospective study evaluated an automated method using an FCN that was trained, validated, and tested with 115, 15, and 26 contrast material–enhanced CT examinations containing 261, 22, and 105 lesions, respectively. Manual detection and segmentation by a radiologist was the reference standard. Performance of fully automated and user-corrected segmentations was compared with that of manual segmentations. The interuser agreement and interaction time of manual and user-corrected segmentations were assessed. Analyses included sensitivity and positive predictive value of detection, segmentation accuracy, Cohen κ, Bland-Altman analyses, and analysis of variance. Results In the test cohort, for lesion size smaller than 10 mm (n = 30), 10–20 mm (n = 35), and larger than ...

26 April 2016 in Clinical Neuroradiology
Verified
Journal Article
Closed access
PDF file
CFChristian Federau
Christian Federau
MCMilena Cerny
Milena Cerny
MRMarion Roux
Marion Roux
PMPascal J. Mosimann
Pascal J. Mosimann
PMPhilippe Maeder
Philippe Maeder
MWMax Wintermark
Max Wintermark

25 August 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JCJ. Conklin
J. Conklin
CHC. Heyn
C. Heyn
MRM. Roux
M. Roux
MCM. Cerny
M. Cerny
MWMax Wintermark
Max Wintermark
CFC. Federau
C. Federau
BACKGROUND AND PURPOSE: Despite a recent resurgence, intravoxel incoherent motion MRI faces practical challenges, including limited SNR and demanding acquisition and postprocessing requirements. A simplified approach using linear fitting of a subset of higher b-values has seen success in other organ systems. We sought to validate this method for evaluation of brain pathology by comparing perfusion measurements using simplified linear fitting to conventional biexponential fitting. MATERIALS AND METHODS: Forty-nine patients with gliomas and 17 with acute strokes underwent 3T MRI, including DWI with 16 b-values (range, 0–900 s/mm2). Conventional intravoxel incoherent motion was performed using nonlinear fitting of the standard biexponential equation. Simplified intravoxel incoherent motion was performed using linear fitting of the log-normalized signal curves for subsets of b-values >200 s/mm2. Comparisons between ROIs (tumors, strokes, contralateral brain) and between models (biexponential and simplified linear) were performed by using 2-way ANOVA. The root mean square error and coefficient of determination (R2) were computed for the simplified model, with biexponential fitting as the reference standard. RESULTS: Perfusion maps using simplified linear fitting were qualitatively similar to conventional biexponential fitting. The perfusion fraction was elevated in high-grade (n = 33) compared to low-grade (n = 16) gliomas and was reduced in strokes compared to the contralateral brain (P < .001 for both main effects). Decreasing the number of b-values used for linear fitting resulted in reduced accuracy (higher root mean square error and lower R2) compared with full biexponential fitting. CONCLUSIONS: Intravoxel incoherent motion perfusion imaging of common brain pathology can be performed by using simplified linear fitting, with preservation of clinically relevant perfusion information.