1 December 2014 in Dental Materials
24 August 2020 in Nature Communications
Nematic states are characterized by rotational symmetry breaking without translational ordering. Recently, nematic superconductivity, in which the superconducting gap spontaneously lifts the rotational symmetry of the lattice, has been discovered. In nematic superconductivity, multiple superconducting domains with different nematic orientations can exist, and these domains can be controlled by a conjugate external stimulus. Domain engineering is quite common in magnets but has not been achieved in superconductors. Here, we report control of the nematic superconductivity and their domains of SrxBi2Se3, through externally-applied uniaxial stress. The suppression of subdomains indicates that it is the Δ4y state that is most favoured under compression along the basal Bi-Bi bonds. This fact allows us to determine the coupling parameter between the nematicity and lattice distortion. These results provide an inevitable step towards microscopic understanding and future utilization of the unique topological nematic superconductivity.
1 December 2021 in Journal of the Mechanical Behavior of Biomedical Materials
16 January 2019 in Journal of Applied Physics
We seek for novel electronic phenomena by using external strain engineering, namely, by the application of external uniaxial strain. A piezoelectric-based uniaxial strain cell has been recently developed by Hicks et al. and successfully utilized for studies of various unconventional superconductors. Here, we propose a modified design that minimizes effects originating from the asymmetry of the strain cell design, in particular with minimal bending moments, by placing the sample at the axis of mirror symmetry of the device to balance out the reactive forces. Results of finite element analyses indicate that placing the sample offset to the axis of the mirror symmetry indeed causes an increase of strain inhomogeneity up to 10%, both at room temperature and at 4.2 K. Furthermore, we found that this bending reduces the overall achievable strain down to 30% of its maximal value without the bending. We also experimentally demonstrate the potential of our constructed device by tracking the displacement of the anvils of the strain cell with a parallel plate capacitor. The full range of motion of the piezo-stacks were demonstrated at room temperature. With a sample and at 0.9 K, we achieved a uniaxial strain of %, which is enough to induce electronic change in typical materials.
27 February 2015 in Applied Optics
A Michelson interferometer-based approach was developed to accurately measure the axial shrinkage dynamics and topography of fast curing resin-based composites. The main components of the apparatus consist of a helium–neon laser and a charged coupled device camera with an acquisition rate of 122 frames per second capable of measuring shrinkage rates of up to at a spatial resolution of 20.6 μm. The accuracy of the data obtained using this approach was determined by comparison with data obtained using spherical concave mirrors of known focal lengths, and with data collected using a photodiode and stylus-based profilometer.
1 August 2016 in Dental Materials