1 August 2009 in Journal of Geotechnical and Geoenvironmental Engineering
This paper is a critical evaluation of the interpretation criteria of drilled shafts under axial compression loading. A wide variety of load test data are used for analysis, and these data are divided into drained and undrained databases. The interpretation criteria are examined from these load test results to establish a consistent compression interpretation criterion. Among these criteria, the range of each interpretation method presents approximately the same trend for both drained and undrained conditions. The statistical results show that the smaller the compression displacement, the higher the coefficient of variation. Moreover, the undrained load test results reveal less variability than the drained results. The load-displacement curve of a drained loading also demonstrates more ductility than that for undrained loading. Based on these analyses, the relative merits and interrelationships of these criteria are established, and specific design recommendations for the interpretation of compression dri...
1 September 2019 in Journal of Geotechnical and Geoenvironmental Engineering
This study compiles 320 static-load tests to quantify the model factors in reliability-based limit-state design of drilled shafts under axial loading. At ultimate limit-state, the model factor is defined as the ratio of the measured capacity to the calculated capacity. It characterizes the bias in capacity calculation. The measured capacity is interpreted from load test data by the modified Davisson offset limit, and current design methods are utilized to compute the ultimate axial capacity. The load-displacement data are simulated by two-parameter hyperbolic curves. Based on the database, the statistics and probability distributions of the capacity and load-displacement model factors are established. Several copulas are selected for goodness-of-fit tests on the observed correlation of the hyperbolic model factors. The model factor at serviceability the limit-state is then described by two correlated hyperbolic parameters. Finally, the model statistics are applied to implement the LRFD of drilled shafts under axial loading by Monte Carlo simulations.
28 June 2013 in KSCE Journal of Civil Engineering
An extensive evaluation of capacity interpretation criteria is presented for driven Precast Concrete (PC) piles under axial compression loading. A database of static load tests for round and square cross-section piles under both drained and undrained loading was developed and utilized in the analysis. The compiled data are generalized into four groups (round — drained, square — drained, round — undrained, and square — undrained) to examine the differences in their behavior. Generally, similar trends for each criterion are noted for the four groups. Statistical analyses show a decreasing COV with increasing pile displacement, and the drained load tests show less variability than the undrained load tests. For drained loading, somewhat higher interpreted capacities are exhibited by round piles than by square piles. In addition, a slightly stiffer normalized load-displacement curve is shown for the drained loading compared to the undrained loading. The drained and undrained databases are further sub-divided by hammer type (drop, air/steam, diesel, and hydraulic) to explore the effects of driving energy and driving resistances on pile capacity. Based on these analyses, the relative merits and interrelationships of these criteria are established, and design recommendations for the use of these methods are suggested in terms of normalized capacity and displacement.
1 August 2010 in Journal of Geotechnical and Geoenvironmental Engineering
Representative interpretation criteria are examined to evaluate the capacity of nonrigid drilled shaft foundations under lateral loading. A wide variety of lateral load test data are used for analysis, and these data are divided into drained and undrained databases. The interpretation criteria are applied to these load test data to establish consistent lateral interpretation criteria. Among these criteria, the results are generally comparable for both drained and undrained loading. The statistical results show that the smaller the displacement or rotation is, the higher the coefficient of variation. Moreover, the undrained load test results present somehow less variability than the drained results. Based on these analyses, the relative merits and interrelationships of these criteria are established, and specific design recommendations for the interpretation of lateral drilled shaft load test are given in terms of capacity, displacement, and rotation.
1 October 2008 in Journal of Geotechnical and Geoenvironmental Engineering
Representative interpretation criteria are examined to evaluate the capacity of drilled shaft foundations under axial uplift loading. A wide variety of uplift load test data are used, and these data are divided into drained and undrained databases. The interpretation criteria are applied to these load test data to establish a consistent uplift interpretation criterion. The results are comparable for both drained and undrained loading. In general, the undrained load test results show somewhat less variability than the drained results. Based on these analyses, the QL2 , Q0.5in , and slope tangent methods are the more reliable and consistent, and specific design recommendations for the interpretation of uplift drilled shaft load test are given, in terms of both capacity and displacement.
25 July 2014 in Geomechanics and Engineering
MMMaria Cecilia M. Marcos