Omer Kaynakli

Omer Kaynakli

Auto-generated profile, based on publicly available information

Omer Kaynakli

Department of Mechanical Engineering, Bursa Uludag University, Bursa, Turkey

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2019 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
ACAhmet Serhan Canbolat
Ahmet Serhan Canbolat
HBHüsnü Bademlioğlu
Hüsnü Bademlioğlu
OKO. Kaynakli
O. Kaynakli
In this study, the performance of organic Rankine cycle (ORC), which produces electrical energy, was examined by using a geothermal resource with a temperature of 145°C. The fluids used in the system were determined as dry type fluids, and R142b, R227ea, R245fa, R600, and R600a were preferred as a working fluid. Within the scope of this study, energy and exergy analysis of the system was performed for different evaporator pressures (1000–2000 kPa). With the help of these analyses, the performances of the cycle elements were examined and the first and second law efficiencies of the system were compared for different refrigerants. Considering the selection of refrigerant, and evaporator pressure within the scope of this study, the first and second law efficiencies of the cycle have enhanced maximum of 4.86% and 19.78%, respectively.

9 July 2017 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
HUHande Ufat
Hande Ufat
OKOmer Kaynakli
Omer Kaynakli
NYNurettin Yamankaradeniz
Nurettin Yamankaradeniz
RYRecep Yamankaradeniz
Recep Yamankaradeniz
It is important to provide a regular unidirectional air distribution in an operating room to reduce the number of particles. Measurements were taken in the one of the operating rooms at Uludag University Medical School, with laminar air flow unit and two-cornered outlet which was thought to have some airflow problems. Moreover, a three-dimensional computational fluid dynamics model has been developed where the measurements were taken in. The distributions of air velocity, temperature, and relative humidity have been examined and compared with the measurements to validate the computational fluid dynamics analyses. In addition to present model, four-cornered outlet operating room has been analyzed and compared with the results of two-cornered one. It is concluded that the case of four-cornered outlet provides more suitable thermal distribution, which results in a reduction of the particle numbers in the interior. Although there is no significant change in temperature and relative humidity in the operating room, air distribution changes dramatically.