Hasan Dirik

Hasan Dirik

Auto-generated profile, based on publicly available information

Hasan Dirik

Sinop Üniversitesi

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CGCenk Gezegin
Cenk Gezegin
OOOkan Ozgonenel
Okan Ozgonenel
HDHasan Dirik
Hasan Dirik
Transformers are the most expensive element of a power system, and so transformer monitoring systems are becoming more important as loads increase. Under heavy loading conditions, the hot-spot temperature of a transformer is the most critical parameter to determine the limit of loading. Therefore, to make an accurate estimation of hot-spot temperature and maintain the reliability of a power system, dynamic thermal models or methods must be employed. Due to the complexity of thermal phenomena, the methods presented so far needs to be improved to reduce computational errors. This is particularly the case for variable loading conditions and power utilities are still in need of good techniques. This paper describes two methods to determine temperature in single-phase, oil-immersed transformers. The first method calculates average windings temperature (AWT) using the voltage and current from primary and secondary windings. The second method, which uses data from the first method, determines the hot-spot temperature of the transformer. The methods have been investigated by experiments on a 30 kVA single-phase transformer and verified the results using COMSOL ™ software. Our methods have proven more accurate than the IEEE Annex G method.

14 June 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HDHasan Dirik
Hasan Dirik
IDİsmail Umut Duran
İsmail Umut Duran
CGCenk Gezegin
Cenk Gezegin
As the ratio of nonlinear loads fed from grids are increasing day by day, harmonic pollution problems seem to be more and more serious. Problems related to harmonics are the main sources of economic losses at power systems. In order to reduce economic losses and provide cleaner grids, utilities need to find new and reasonable ways to control harmonic pollution. A proper way of this is to enforce monetary sanctions to the consumers who are responsible for harmonic pollution. With this way, consumers are encouraged to take necessary actions for reducing their harmonic emissions. However, utilities still need a fair, reasonable, and applicable method for this aim to control harmonic emissions of costumers. In this context, a new method to compute the contribution of individual customers to harmonic pollution of grids is presented in this paper. For this aim, an index representing the harmonic emission level of loads is defined. In the development of the method, responsibilities of utilities and consumers, harmonic limits specified by standards and effects of each harmonic component on grid elements have been especially taken into account. Thus, it has been possible to form a fair, reasonable, and applicable method. Validity of the method is tested by simulations, and results are discussed. At the end of this paper, an experimental setup designed for real-time metering is also presented. This demonstrated the applicability of such a metering device that uses the proposed method.

30 November 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
HDHasan Di̇rİk
Hasan Di̇rİk
CGCenk Gezegi̇n
Cenk Gezegi̇n
HDHasan Serdar Di̇rİk
Hasan Serdar Di̇rİk

1 November 2014 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
HDHasan Dirik
Hasan Dirik
MÖMuammer Özdemir
Muammer Özdemir
Quality problems encountered in power systems usually originate from reactive and harmonic current components drawn by non‐linear loads. Therefore the extraction of reactive and harmonic current components from distorted current waveform is a vital issue in the works aiming to monitor and eliminate power quality problems. In this study, a new method that provides the extraction of active, reactive and harmonic current components from distorted current is presented. The method has been based on the differential equation of the single‐phase source‐load system. The proposed method performs computations by using a sliding sampling window that has a width of half of the fundamental cycle. Immunity to noise, being less affected from frequency deviations and being not influenced from dc component that may exist in load currents are some other advantages of the proposed method. The method has been analysed and compared to two commonly used methods, namely discrete Fourier transform (DFT) and dq, by using a series of simulations that have been executed in Matlab/Simulink environment. Simulation results demonstrated the effectiveness of the proposed method.

31 July 2019 in Düzce Üniversitesi Bilim ve Teknoloji Dergisi
Verified
Journal Article
Open access
PDF file
HDHasan Di̇rİk
Hasan Di̇rİk
CGCenk Gezegi̇n
Cenk Gezegi̇n
Transformatörlerin termal özellikleri, yüklenebilme sınırlarını ve ömürlerini belirleyen önemli değişkenleri içerir. Bu değişkenler arasında transformatörlerin sargı sıcaklığı en önemli değişkendir. Sargı sıcaklığının değeri transformatörün içyapısındaki kayıpların neticesinde açığa çıkan ısı enerjinin miktarı ile dış ortama atılan ısı enerjisi miktarı arasındaki denge tarafından belirlenir. Bu noktada transformatörlerin gerçek zamanlı çalışmaları esnasındaki güç kayıplarının iç sıcaklığa önemli etkisinin olduğu anlaşılır. Bu kayıplar demir ve bakır kayıpları olmak üzere iki alt gruba ayrılır. Her iki kayıp türünün sargı sıcaklığına ve özellikle en sıcak nokta sıcaklığına olan etkisi farklı orandadır. Bu yüzden transformatör sıcaklık hesaplamalarında kullanılan termal modellerin hemen hemen hepsinde her iki kayıp türü farklı oranlarda dikkate alınır. Bu yüzden demir ve bakır kayıplarının ayrı ayrı hesaplanabilmesi termal modellerin doğruluğu bakımından önemli bir avantaj sunar. Bu çalışmada, bu yüzden, gerçek zamanlı transformatör verileri kullanılarak kayıpların nasıl hesaplanabileceği üzerine bir yöntem verilmiştir. Yöntem tek-fazlı transformatörün primer ve sekonder tarafı gerilimlerini ve akımlarını kullanmaktadır. Yöntemin matematiksel eşitlikleri transformatörlerin T-eşdeğer devresi kullanılarak elde edilmiştir. Burada, önerilen yöntemin öncelikle matematiksel temelleri verilmiştir. Sonrasında ise yöntemin hem Matlab/Simulink ortamında yapılmış olan benzetimler ile hem de bir 5 kVA gücüne sahip transformatör üzerinde yapılan deneysel çalışmaları ile yapılmış olan inceleme sonuçları verilmiştir. Sonuçlar kayıpların önerilen yöntem ile oldukça hassas bir şekilde elde edilebildiğini göstermektedir. Hesaplamaların harmonikli koşullarda da geçerli olması ve gerçek zamanlı veriler ile yapılıyor olması önemli iki avantajdır.

30 September 2018 in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
Verified
Journal Article
Open access
PDF file
CGCenk Gezegi̇n
Cenk Gezegi̇n
HDHasan Di̇rİk
Hasan Di̇rİk
MÖMuammer Özdemi̇r
Muammer Özdemi̇r
Güç sistemlerinin pahalı donanımlarından olan transformatörlerin izlenmesi son yılların önemli konularından biridir. Transformatör izleme sistemleri genellikle arızaların tespiti, transformatör ömrünün belirlenmesi, kayıpların ölçümü ve sargı sıcaklıklarının belirlenmesi amacıyla kullanılır. İzlemede kullanılan önemli parametrelerden biri transformatör sargı direncidir. Bu yüzden, bu çalışmada yeni bir sargı direnci izleme yöntemi sunulmuştur. Yöntem transformatörlerin eşdeğer devresi ve güç eşitlikleri kullanılarak geliştirilmiştir. Hesaplamalarda transformatörlerin primer ve sekonder tarafı akım ve gerilim değerleri kullanılmaktadır. Böylece transformatörlerin ortalama sargı direncinin gerçek zamanlı izlenmesi sağlanmaktadır. Yöntem tek fazlı transformatörlere uygulanabildiği gibi yıldız-yıldız ve üçgen-yıldız bağlı transformatörler için de kullanılabilmektedir. Bu çalışmada, öncelikle yöntemin matematiksel işlem adımları verilmiştir. Sonrasında Matlab ortamında yapılan benzetim çalışmaları ve iki farklı transformatör üzerinde gerçekleştirilen deneysel çalışmalar verilmiştir. Benzetimler ve deneysel çalışmalar yöntemin geçerliliğini açık bir biçimde ortaya koymuştur.