Zhen Huang

Zhen Huang

Auto-generated profile, based on publicly available information

Zhen Huang

Department of Automation, Zhejiang University of Technology, Hangzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
FGFanghong Guo
Fanghong Guo
ZLZhuocheng Li
Zhuocheng Li
JWJinhui Wu
Jinhui Wu
ZHZhen Huang
Zhen Huang
HNHongjie Ni
Hongjie Ni
Networked microgrids (NMGs) have emerged to tackle the intricate challenge posed by today's increasing power demands. However, the configuration of NMGs is subject to change due to revamping, faults, or privacy issues within each microgrid (MG), and existing control mechanisms cannot realize configurable control with a privacy guarantee. To address this control problem, we offer a fresh perspective on the control framework by proposing a configurable decentralized-distributed control strategy using directed graphs with minimal communication and less privacy disclosure risk. Specifically, one distributed generator (DG) in each MG is designated as the leader to ensure complete privacy protection in a decentralized manner, eliminating the need to exchange information among other NMGs. Follower DGs communicate exclusively with their leader DGs within clusters, enhancing the control performance. Furthermore, by introducing a novel leaky integral control law, the proposed configurable control framework can adapt to different NMG configurations without redesigning controllers. The stability of the entire NMG system is analyzed rigorously. Finally, the effectiveness of the proposed control framework is demonstrated in solving secondary frequency restoration and active power-sharing problems of NMGs. The experimental test system is built on the OPAL-RT system, and the results show the superiority of our proposed control method under decentralized, distributed, and hybrid NMG configurations.

9 July 2024 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
FGFanghong Guo
Fanghong Guo
ZHZhen Huang
Zhen Huang
JWJinhui Wu
Jinhui Wu
ZLZhuocheng Li
Zhuocheng Li
SLShan Liu
Shan Liu
LXLantao Xing
Lantao Xing
In this paper, the optimal power allocation and frequency restoration problem for islanded alternating-current (AC) microgrids (MGs) is addressed under false data injection (FDI) frequency sensor attacks. Firstly, a distributed proportional and integral secondary controller is developed without considering the FDI attack. In addition to the advantages of the traditional distributed structure, this controller also has more advantages, such as simple tuning and robustness to external disturbances. Also, the theoretical analysis proves that the developed controller can drive the system frequency to the reference value, while the optimal power distribution is realized. Then, a distributed intermediate-estimate-based resilient secondary control strategy is further designed to enhance the resilience of cyber-physical AC MG to FDI attacks on frequency sensors. Compared to most of existing resilient control strategies, our proposed controller can not only maintain the frequency stability, but also ensure the accuracy of optimal power sharing among distributed generators (DGs). Finally, an islanded AC MG test system is built on a real-time testing platform to illustrate and verify the effectiveness of the developed methods.