In recent years, the rapid development of the transportation industry has led more and more scholars to devote themselves to the research of its drive motor. Among all relevant aspects of research, thermal management is absolutely the one that has been neglected in the past but is now getting more and more attention. This paper presents a comprehensive and detailed summary of motor thermal management for transportation, including thermal analysis methods, key factors in thermal analysis, and various cooling methods. Firstly, the three mainstream thermal analysis methods are introduced, and the improvement of each method in recent years is summarized. The feasibility and advantages of multi-method united simulation are discussed, and some novel thermal analysis methods are also listed. Then, key factors in thermal analysis are analyzed in depth and the determination methods are given. In the fourth section, the research related to motor cooling methods in recent years is reviewed, including the improvement of traditional methods and novel methods. Finally, suggestions for the future development of thermal management are given. The key is not only to reveal novel analysis methods, tools, methodologies, cooling structures, strategies, pros and cons, and foresight for the advanced drive motor but also to provide guidelines for predicting the temperature distribution and selecting the appropriate cooling methods in the motor design process.
21 December 2022 in IEEE Transactions on Transportation Electrification
This research takes an 18.5kW automotive synchronous reluctance motor (SynRM) with 4-layer “C” type flux barrier rotor structure as the object and studies the influence of the end position of each layer of flux barrier on torque ripple. Compare different flux barrier end deflection schemes, the effect of flux barrier end deflection on torque ripple is studied, and the effect of deflection angle on torque ripple and electromagnetic performance is obtained. The air-gap flux density waveforms before and after the flux barrier end deflection and the radial and tangential components of its harmonics are analyzed. The action mechanism of flux barrier deflection on torque ripple and electromagnetic performance is obtained by analyzing the phase relationship between tooth harmonics and fundamental waveforms. Besides, the deflection scheme of the flux barrier end with optimal performance is given. A SynRM performance improvement method through phase cancellation between the tooth harmonics and the fundamental wave is proposed. Finally, the experimental platform is built to verify the accuracy of the simulation calculation.
11 January 2024 in Case Studies in Thermal Engineering
The interior permanent magnet (IPM) motor is commonly used as the drive motor for the electric car due to high torque density, high efficiency, and good field weakening speed regulation capabilities. In this paper, an 80kW IPM motor with uneven air gap is designed as a drive motor for an electric bus. The total weight of the electric bus is 11000 kg, and its length/width/height is 8190/2400/2960 mm, respectively. In-depth analysis and research have also been conducted on the power parameter coordination between the IPM motor and the electric bus. The operational and mechanical characteristic curves of the drive motor under a straight-line driving cycle are analyzed through simulation, and the simulation results are verified through experiments. Comparing the results of simulation and experiment, it is known that the error of the rated torque is as high as 4.8%, and the error of the peak torque is as high as 8.6%.
Due to the complex structure and large size of large‐capacity oil‐immersed power transformers, it is difficult to predict the winding temperature distribution directly by numerical analysis. A 180 MVA, 220 kV oil‐immersed self‐cooling power transformer is used as the research object. The authors decouple the internal fluid domain of the power transformer into four regions: high voltage windings, medium voltage windings, low voltage windings, and radiators through fluid networks and establish the 3D fluid‐temperature field numerical analysis model of the four regions, respectively. The results of the fluid network model are used as the inlet boundary conditions for the 3D fluid‐temperature numerical analysis model. In turn, the fluid resistance of the fluid network model is corrected according to the results of the 3D fluid‐temperature field numerical analysis model. The prediction of the temperature distribution of windings is realised by the coupling calculation between the fluid network model and the 3D fluid‐temperature field numerical analysis model. Based on this, the effect of the loading method of the heat source is also investigated using the proposed method. The hotspot temperatures of the high‐voltage, medium‐voltage, and low‐voltage windings are 89.43, 86.33, and 80.96°C, respectively. Finally, an experimental platform is built to verify the results. The maximum relative error between calculated and measured values is 4.42%, which meets the engineering accuracy requirement.
29 June 2022 in Case Studies in Thermal Engineering