Einat Slonimsky

Einat Slonimsky

Auto-generated profile, based on publicly available information

Einat Slonimsky

From Penn State University (A.K.), and the Penn State Health Milton S. Hershey Medical Center, Department of Radiology, Division of Neuroradiology Hershey, Pennsylvania, United States. (E.S., S.N.H., J.K.M.)

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GSGuy Slonimsky
Guy Slonimsky
JMJohnathan D. McGinn
Johnathan D. McGinn
NGNeerav Goyal
Neerav Goyal
HCHenry Crist
Henry Crist
MHMax Hennessy
Max Hennessy
ESEinat Slonimsky
Einat Slonimsky
Our purpose was to classify acute invasive fungal rhinosinusitis (AIFR) caused by Mucor versus Aspergillus species by evaluating computed tomography radiological findings. Two blinded readers retrospectively graded radiological abnormalities of the craniofacial region observed on craniofacial CT examinations obtained during initial evaluation of 38 patients with eventually pathology-proven AIFR (13:25, Mucor:Aspergillus). Binomial logistic regression was used to analyze correlation between variables and type of fungi. Score-based models were implemented for analyzing differences in laterality of findings, including the ‘unilateral presence’ and ‘bilateral mean’ models. Binary logistic regression was used, with Score as the only predictor and Group (Mucor vs Aspergillus) as the only outcome. Specificity, sensitivity, positive predictive value, negative predictive value and accuracy were determined for the evaluated models. Given the low predictive value of any single evaluated anatomical site, a ‘bilateral mean’ score-based model including the nasal cavity, maxillary sinuses, ethmoid air cells, sphenoid sinus and frontal sinuses yielded the highest prediction accuracy, with Mucor induced AIFR correlating with higher prevalence of bilateral findings. The odds ratio for the model while integrating the above anatomical sites was 12.3 (p < 0.001). PPV, NPV, sensitivity, specificity and accuracy were 0.85, 0.82, 0.92, 0.69 and 0.84 respectively. The abnormal radiological findings on craniofacial CT scans of Mucor and Aspergillus induced AIFR could be differentiated based on laterality, with Mucor induced AIFR associated with higher prevalence of bilateral findings.

1 May 2018 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
ESEinat Slonimsky
Einat Slonimsky
JKJacob Korach
Jacob Korach
TPTamar Perri
Tamar Perri
TDTima Davidson
Tima Davidson
SASara Apter
Sara Apter
YIYael Inbar
Yael Inbar
Objective: The aim of the study was to evaluate the radiological characteristics of gynecological lymphoproliferative disease (LPD) and specific imaging features that may suggest the diagnosis. Methods: Two readers conducted a retrospective evaluation of imaging studies of 13 female patients presenting with a gynecological LPD. A literature review was also performed. Results: Of the 13 evaluated women, 9 had ovarian involvement, 3 had cervical involvement, and 1 had uterine involvement. The most common lesion characteristics were homogenous masses (11), with mild contrast enhancement (9), followed by soft-tissue necrosis (4), prominent blood vessels displaced by the lesions (4), linear arrangement of cysts at the periphery of the ovaries (3), and “touching” ovaries in all cases of bilateral ovarian involvement. Conclusions: A solid large homogeneous mass with mild contrast enhancement should alert the radiologist to the possibility of the differential diagnosis of LPD. Radiologists should be “the gatekeepers” by raising this possibility to avoid unnecessary surgery and enable appropriate treatment.

17 September 2019 in BMJ Open Quality
Verified
Journal Article
Open access
PDF file
SSShyam Sabat
Shyam Sabat
PKPaul Kalapos
Paul Kalapos
ESEinat Slonimsky
Einat Slonimsky
Introduction: The purpose of this study was to understand the source and the reason for the phone calls to our neuroradiology suit and to quantify the size of the problem in terms of duration of individual and aggregated calls. Materials and methods: Observation of the neuroradiology reading room for the entire duration of the working hours over three non-consecutive days was performed, and included telephone calls start time, end time and calls duration for incoming telephone calls. After each phone call the recipients were queried on the details of the phone call; the origin of the call, the reason for the call and the response. Results: The average total number of minutes (min) spent on the phone each day was 64 min per working day with a total of 39 phone calls per day and 4.4 per hour on average. The trainees answered 71% of the phone calls with additional intervention by attending in 13% of phone calls. The most common source of phone calls was from either the MRI/CT technicians (48%), followed by providers (20%) and returning pages (18%). Conclusion: Cumulative time spent on the phone by neuroradiologists in the reading room ended up in more than an hour per working day, while trainees were taking the majority of phone calls. Most phone calls originated from technicians, hence, requiring specific solutions to mitigate this kind of interruption.

17 September 2020 in Current Pharmaceutical Design
Verified
Journal Article
Open access
PDF file
ESEinat Slonimsky
Einat Slonimsky
Mark TulchinskyMark Tulchinsky
Mark Tulchinsky
This review of radioactive iodide treatment (RAIT) extends from historical origins to its modern utilization in differentiated thyroid cancer (DTC). The principles embedded in the radiotheragnostics (RTGs) paradigm are detailed. The diverse approaches in current practice are addressed, and this broad variability represents a major weakness that erodes our specialty’s trust-based relationship with patients and referring physicians. The currently developing inter-specialty collaboration should be hailed as a positive change. It promises to clarify the targetsbased terminology for RAIT. It defines RAIT of post total thyroidectomy (PTT) presumably benign thyroid as ‘remnant ablation’ (RA). ‘Adjuvant treatment’ (AT) referrers to RAIT of suspected microscopic DTC that is inherently occult on diagnostic imaging. RAIT directed at DTC lesion(s) overtly seen on diagnostic imaging is termed ‘treatment of known disease’ (TKD). It was recently recognized that a ‘recurrent’ DTC is actually occult residual DTC in the majority of cases. Thyroglobulin with remnant uptake concord (TRUC) method was developed to validate that a benign remnant in the post-thyroidectomy neck bed, as quantified by the RAI uptake, is concordant with a measured thyroglobulin (Tg) level at the time of the initial post-thyroidectomy evaluation. It allows recognition of occult residual DTC contribution to post-thyroidectomy Tg. Case examples demonstrate application of the TRUC method for a logical selection of a specific RAIT category, using imaging-guided identification and management of RAI-avid versus RAI-nonavid residual DTC, i.e. the radiotheragnostics paradigm.

1 May 2021 in Current Problems in Diagnostic Radiology
Verified
Journal Article
Closed access
GSGuy Slonimsky
Guy Slonimsky
GHGloria Hawng
Gloria Hawng
DGDavid Goldenberg
David Goldenberg
EGEric Gagnon
Eric Gagnon
ESEinat Slonimsky
Einat Slonimsky

22 November 2021 in Cureus
Verified
Journal Article
Open access
ESEinat Slonimsky
Einat Slonimsky
BZBrad Zacharia
Brad Zacharia
AMAlex Mamourian
Alex Mamourian
Background: Programmable shunts can be adjusted to optimize CSF diversion in patients with hydrocephalus without the need for re-operation. Currently, all shunts incorporate radiopaque markers so that their setting can he determined on skull X-ray images. The purpose of this study was to evaluate whether the shunt setting could also be determined ex vivo and in vivo using the data from a standard head CT scan since one is nearly always obtained when patients with VP shunts present with new symptoms that could be due to shunt malfunction. Materials and Methods: Four commonly used programmable shunts were attached to a dried skull and scanned using a variety of CT techniques. The shunts imaged were the Certas (TM) Plus (Codman, Raynham, Massachusetts), Polaris (R) (Sophysa, Orsay, France), proGAV 2.0 (R) (Braun, Bethlehem, Pennsylvania), and Hakim (R) (Codman, Raynham, Massachusetts). Each shunt was scanned at two different valve settings using multiple CT techniques: CTDI vo l 75, 140kVp, 330mAs, CTDI(vol)60, 120kVp 390mAs, CTDI(v)(ol)40, 80kVp with 430mAs, 140kVp with 215mAs. Image reconstruction with and without CT metal suppression software was used for all scans, and the data was reconstructed into volume-rendered images. We enlisted ten observers to review the volume-rendered images only. After a short set of training slides viewed by all observers, they were asked to predict the shunt setting for each valve along with their level of confidence. One clinical case of a patient with a programmable valve was evaluated on a CT scan. Results: Using the volume-rendered images only, the two shunt settings of the Polaris shunt were correctly predicted by all the observers and in nine of 10 settings for the Certas (TM) Plus valve. For the Hakim (R) shunt and the proGAV 2.0 (R) shunt, setting prediction accuracy was 0% and 10%, respectively. In one clinical case, the programmable valve setting could be determined from the CT scan data. Conclusion: The valve setting of at least two currently available programmable shunts can be determined using volume-rendered images generated from CT data. Reconstructions using metal suppression software were rated as superior and may be necessary for some valve designs.