Jinlong Wang

Jinlong Wang

Auto-generated profile, based on publicly available information

Jinlong Wang

School of Electrical Engineering of Shandong University, Jinan, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JWJinlong Wang
Jinlong Wang
PWPeng Wang
Peng Wang
Haoran ZhaoHaoran Zhao
Haoran Zhao
FYFutao Yang
Futao Yang
Existing wind farm impedance analyzes using aggregated impedance models neglect the influence mechanisms of dynamic couplings between wind farm control (WFC), wind turbines, and collector lines on system stability. This article proposes a novel comprehensive impedance model (CIM) for the wind farm based on the doubly-fed induction generator (DFIG), considering multiple dynamic couplings for thorough impedance analysis. At the DFIG level, small-signal characteristics of rotor speed are introduced into the impedance model to reflect couplings between mechanical and electromagnetic dynamics. Meanwhile, at the wind farm level, couplings between the WFC and DFIGs are represented as a current source controlled by voltage and current perturbations at the wind farm point of common coupling (PCC), connected in parallel with the original DFIG impedance. Since the PCC voltage and current are associated with all DFIGs and collector lines, this controlled source effectively captures their couplings. Analysis with CIM reveals that considering mechanical dynamics improves the accuracy of DFIG impedance in the low-frequency band, while the WFC affects the impedance characteristics of the wind farm in the full-frequency range. Moreover, excessively large WFC proportional-integral parameters can lead to system destabilization. Simulation and experimental results confirm the validity of the CIM and its precise application in stability analysis.

29 April 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SQShiyao Qin
Shiyao Qin
PWPeng Wang
Peng Wang
SLShaolin Li
Shaolin Li
Haoran ZhaoHaoran Zhao
Haoran Zhao
JWJinlong Wang
Jinlong Wang
JLJia Luo
Jia Luo
Online identification of the stability region for the wind power plant (WPP) equipped with permanent magnet synchronous generators encounters two challenges: calculating high-order impedance and estimating the stability boundary of multiple parameters. To address these challenges, the mechanism-data-driven equivalent impedance for each branch of the WPP is developed, and the high-dimensional stability region boundary is established with a machine learning-based algorithm. In mechanism-driven modeling, the aggregated impedance is derived using parallel calculation. In data-driven modeling, different key parameters in wide frequency bands are modified to ensure the accuracy of the equivalent impedance. The equivalent impedance derived through the mechanism-data-driven approach deviates from the detailed impedance within $\pm 1\%$ . Regarding the stability region estimation, the fuzzy support vector machine is applied. To improve the speed of the online training of the stability region, the weighted Mahalanobis distance is employed to distinguish the importance of stability index samples. In validation, the stability regions of the power of the WPP are established. The impacts of the static var generator (SVG) on the stability performance are analyzed, and regulating the reactive power of the SVG can enhance small-signal stability. The stability region estimation and enhancement are verified through time-domain simulations and experiments in a controller-hardware-in-loop platform.

9 June 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JWJinlong Wang
Jinlong Wang
Haoran ZhaoHaoran Zhao
Haoran Zhao
PWPeng Wang
Peng Wang
Yonghao GuiYonghao Gui
Yonghao Gui
Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. This article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the $\alpha \beta$-frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

24 August 2024 in Sustainable Energy, Grids and Networks
Verified
Journal Article
Closed access
JWJinlong Wang
Jinlong Wang
HZHaoran Zhao
Haoran Zhao
PWPeng Wang
Peng Wang