Mark E. Rentschler

Mark E. Rentschler

Auto-generated profile, based on publicly available information

Mark E. Rentschler

Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2018 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
CLCarlye A. Lauff
Carlye A. Lauff
DKDaria Kotys-Schwartz
Daria Kotys-Schwartz
MRMark E. Rentschler
Mark E. Rentschler

17 April 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CMCarlos Martín-Isla
Carlos Martín-Isla
VCVíctor Manuel Campello
Víctor Manuel Campello
CICristian Izquierdo
Cristian Izquierdo
KKKaisar Kushibar
Kaisar Kushibar
CSCarla Sendra-Balcells
Carla Sendra-Balcells
KLKarim Lekadir
Karim Lekadir
In recent years, several deep learning models have been proposed to accurately quantify and diagnose cardiac pathologies. These automated tools heavily rely on the accurate segmentation of cardiac structures in MRI images. However, segmentation of the right ventricle is challenging due to its highly complex shape and ill-defined borders. Hence, there is a need for new methods to handle such structure's geometrical and textural complexities, notably in the presence of pathologies such as Dilated Right Ventricle, Tricuspid Regurgitation, Arrhythmogenesis, Tetralogy of Fallot, and Inter-atrial Communication. The last MICCAI challenge on right ventricle segmentation was held in 2012 and included only 48 cases from a single clinical center. As part of the 12 th Workshop on Statistical Atlases and Computational Models of the Heart (STACOM 2021), the M&Ms-2 challenge was organized to promote the interest of the research community around right ventricle segmentation in multi-disease, multi-view, and multi-center cardiac MRI. Three hundred sixty CMR cases, including short-axis and long-axis 4-chamber views, were collected from three Spanish hospitals using nine different scanners from three different vendors, and included a diverse set of right and left ventricle pathologies. The solutions provided by the participants show that nnU-Net achieved the best results overall. However, multi-view approaches were able to capture additional information, highlighting the need to integrate multiple cardiac diseases, views, scanners, and acquisition protocols to produce reliable automatic cardiac segmentation algorithms.

31 July 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
BJB. K. Johnson
B. K. Johnson
MNM. Naris
M. Naris
VSV. Sundaram
V. Sundaram
AVA. Volchko
A. Volchko
KLK. Ly
K. Ly
MRM. E. Rentschler
M. E. Rentschler
Shape displays which actively manipulate surface geometry are an expanding robotics domain with applications to haptics, manufacturing, aerodynamics, and more. However, existing displays often lack high-fidelity shape morphing, high-speed deformation, and embedded state sensing, limiting their potential uses. Here, we demonstrate a multifunctional soft shape display driven by a 10 × 10 array of scalable cellular units which combine high-speed electrohydraulic soft actuation, magnetic-based sensing, and control circuitry. We report high-performance reversible shape morphing up to 50 Hz, sensing of surface deformations with 0.1 mm sensitivity and external forces with 50 mN sensitivity in each cell, which we demonstrate across a multitude of applications including user interaction, image display, sensing of object mass, and dynamic manipulation of solids and liquids. This work showcases the rich multifunctionality and high-performance capabilities that arise from tightly-integrating large numbers of electrohydraulic actuators, soft sensors, and controllers at a previously undemonstrated scale in soft robotics.

24 May 2007 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
MRMark E. Rentschler
Mark E. Rentschler
JDJason Dumpert
Jason Dumpert
SPStephen R. Platt
Stephen R. Platt
SFShane M. Farritor
Shane M. Farritor
DODmitry Oleynikov
Dmitry Oleynikov

1 February 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MBMarco Beccani
Marco Beccani
CNChristian Di Natali
Christian Di Natali
LSLevin J. Sliker
Levin J. Sliker
JSJonathan A. Schoen
Jonathan A. Schoen
MRMark E. Rentschler
Mark E. Rentschler
PVPietro Valdastri
Pietro Valdastri
In an open surgery, identification of precise margins for curative tissue resection is performed by manual palpation. This is not the case for minimally invasive and robotic procedures, where tactile feedback is either distorted or not available. In this paper, we introduce the concept of intraoperative wireless tissue palpation. The wireless palpation probe (WPP) is a cylindrical device (15 mm in diameter, 60 mm in length) that can be deployed through a trocar incision and directly controlled by the surgeon to create a volumetric stiffness distribution map of the region of interest. This map can then be used to guide the tissue resection to minimize healthy tissue loss. The wireless operation prevents the need for a dedicated port and reduces the chance of instrument clashing in the operating field. The WPP is able to measure in real time the indentation pressure with a sensitivity of 34 Pa, the indentation depth with an accuracy of 0.68 mm, and the probe position with a maximum error of 11.3 mm in a tridimensional workspace. The WPP was assessed on the benchtop in detecting the local stiffness of two different silicone tissue simulators (elastic modulus ranging from 45 to 220 kPa), showing a maximum relative error below 5%. Then, in vivo trials were aimed to identify an agar-gel lump injected into a porcine liver and to assess the device usability within the frame of a laparoscopic procedure. The stiffness map created intraoperatively by the WPP was compared with a map generated ex vivo by a standard uniaxial material tester, showing less than 8% local stiffness error at the site of the lump.

7 December 2005 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
MRM. E. Rentschler
M. E. Rentschler
JDJ. Dumpert
J. Dumpert
SPS. R. Platt
S. R. Platt
SAS. I. Ahmed
S. I. Ahmed
SFS. M. Farritor
S. M. Farritor
DODmitry Oleynikov
Dmitry Oleynikov