Xilin Zhang

Xilin Zhang

Auto-generated profile, based on publicly available information

Xilin Zhang

Department of Engineering and Applied Physics University of Science and Technology of China Hefei China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2018 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
HCHongli Chen
Hongli Chen
XZXilin Zhang
Xilin Zhang
YZYongsong Zhao
Yongsong Zhao
LCLiankai Cao
Liankai Cao
KSKangli Shi
Kangli Shi
QZQin Zeng
Qin Zeng

1 June 2020 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
XZXilin Zhang
Xilin Zhang
KZKanglong Zhang
Kanglong Zhang
VSV.H. Sanchez-Espinoza
V.H. Sanchez-Espinoza
HCHongli Chen
Hongli Chen

17 June 2020 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
XLXiao Luo
Xiao Luo
XZXilin Zhang
Xilin Zhang
SWShuai Wang
Shuai Wang
RJRong Jiang
Rong Jiang
HCHongli Chen
Hongli Chen

7 March 2020 in International Journal of Energy Research
Verified
Journal Article
Open access
PDF file
LCLiankai Cao
Liankai Cao
XZXilin Zhang
Xilin Zhang
HCHongli Chen
Hongli Chen
The lead‐cooled fast reactor (LFR) offers enhanced safety and reliability with the fine properties of liquid lead and lead alloy. To study accurately the thermal characteristics of fast reactors, the multiscale thermal‐hydraulic coupling simulation is an effective way. Multiscale coupling based on the sub‐channel code has evident advantages on the analysis of fuel assemblies. In this study, a multiscale thermal‐hydraulic analysis of a forced‐circulation, medium‐power LFR under steady‐state and transient conditions is performed with the system code ATHLET and sub‐channel code KMC‐SUBtraC which was developed based on the previous version by modifying the pressure drop correlations and adding the assembly‐level calculation. The codes are one‐way‐coupled, with good efficiency and precision. Transient verification of the sub‐channel code is conducted with the CFD code. In the steady‐state analysis of M2LFR‐1000, mass flow and temperature distributions of the assemblies, sub‐channels, and fuel rods in the hottest assembly are analyzed and the safety performance is investigated. In the transient analysis, two typical DECs (unprotected overpower transient and ULOF+ULOHS) are simulated and the multiscale thermal‐hydraulic characteristics are analyzed. With the negative reactivity feedback, the variations of the temperatures of the coolant and fuel rods are within the safe limits, which shows the inherent safety of the reactor. And the results indicate that the loss of primary flow could increase the risk of cladding corrosion.