31 January 2024 in Measurement Science and Technology
This paper presents a new method that balances accuracy and efficiency in the process of coordinate unification for distributed measurement systems. The method unifies the local coordinate systems of any two measuring units by installing a measuring point on the unit as a marker point and measuring the marker points between them in the working area, combined with the distance between the marker points. Moreover, it enables automatic networking of newly added or moved measurement units with the original measurement network, thereby further improving the efficiency of the dynamic measurements made using the system. The key factors affecting the accuracy of calibration achieved using this method were analysed via simulations. The results indicate that the accuracy of length measurement using the proposed methods is within 0.1 mm m−1 when the measurement units are distributed among the four corners of a rectangle with an area of 50 m2 or more. The experiments indicate that four measurement units calibrated using this method over an area of 35 m2 achieve an accuracy of within 0.2 mm m−1 and 0.1 mm standard deviations for length and three-dimensional coordinate measurements, respectively. Compared with traditional coordinate-unification methods, the proposed method simplifies the calibration process, improves the calibration efficiency by more than ten times, and significantly reduces the calibration time. It is universally applicable in the calibration of large-space distributed measurement systems.
1 September 2023 in AIP Advances
Aiming at the distributed measurement system multi-equipment coordinated measurement, the data measured by each transmitting station are unified under a common coordinate system, which has the problems of complicated operation and high time and cost. In this paper, a fast calibration method for distributed measurement systems based on standard devices is proposed. The method designs a new type of architectural calibration board with non-coplanar measurement nodes, calculates the coordinates of the measurement nodes using geometric relations, solves the initial values of the system parameters, and substitutes the initial values into the L-M least squares algorithm for iterative optimization so that it only needs to carry out one scanning measurement for each reference position in the calibration process to complete the calibration. We designed an experiment in which a distributed measurement system consisting of four transmitting stations measured three standard rods (1650.073, 1156.704, and 875.950 mm) sequentially after calibration in a measuring space of 5 × 5 × 3 m3. The experimental results show that under the premise of ensuring that the measurement accuracy is better than 0.20 mm, the calibration of the parameters of the distributed measurement system can be completed within 20 min.
2 September 2024 in Optics and Lasers in Engineering