Heloisa H Deuzeman

Heloisa H Deuzeman

Auto-generated profile, based on publicly available information

Heloisa H Deuzeman

Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2025 in Clinical and Translational Radiation Oncology
Verified
Journal Article
Open access
LPLeendert Jan Pors
Leendert Jan Pors
MMM. Marinkovic
M. Marinkovic
HDH.H. Deuzeman
H.H. Deuzeman
TVT.H.K. Vu
T.H.K. Vu
EKE.M. Kerkhof
E.M. Kerkhof
NHNanda Horeweg
Nanda Horeweg
Small uveal melanomas are preferably treated with eye-sparing therapies such as brachytherapy or proton beam therapy. Knowledge of clinical outcomes and risk factors is important for personalized patient counselling. Data of all choroidal melanoma patients treated at the Leiden University Medical Center between 2012-2019 with Ruthenium-106 brachytherapy were collected. Time-to-event analyses were performed with the Kaplan-Meier method, risk factors for local failure and visual acuity (VA) decline were identified using Cox proportional hazards models with predefined covariates. 719 patients were included. Median tumour prominence and diameter were 3.8 mm and 11.6 mm, respectively. 52 % of tumours were centrally located, and 19 % were juxtapapillary. Five-year overall survival, eye retention and local failure rates were 83 %, 95 %, and 8 %, respectively. Juxtapapillary location, lower tumour apex doses, and T3-4 tumour stage were significantly associated with local failure. Patients with juxtapapillary tumours had 20 % risk of local failure. Five years posttreatment, 47 % of patients had no functional visual impairment (Snellen VA ≥ 0.5). Lasting functional visual impairment was associated with baseline vision, central tumours, and scleral dose. Patients with central tumours had 75 % risk of mild or worse visual impairment after 5 years. Ruthenium-106 brachytherapy yields good local control and visual outcomes in patients with choroidal melanoma. Juxtapapillary tumours have a high risk of local failure and alternative therapies should be considered in these patients, if available. Patients with central tumours, and those with decreased pre-treatment vision should be counselled on the risk of visual impairment.

13 December 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
SKSander C Kuipers
Sander C Kuipers
JGJérémy Godart
Jérémy Godart
ENEva M Negenman
Eva M Negenman
ACAnouk Corbeau
Anouk Corbeau
AZAndrás G Zolnay
András G Zolnay
MHMischa S Hoogeman
Mischa S Hoogeman
Objective. This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT). Approach. We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach. Six different robustness settings (2–7 mm set-up robustness (SR) plus 3% range robustness (RR)) were used to create those 120 IMPT plans. Each fraction was simulated with a weekly reCT, combined with the sampling of inter- and intrafraction treatment uncertainties. The fraction doses were accumulated to obtain a treatment dose to the target volumes, distinguishing between the low-risk clinical target volume (CTV-T-LR) and the elective CTV (CTV-E). If one of the two targets obtained an adequate coverage for more than 90% of the treatments, different anisotropic margins were sampled on top of the robustness setting to the other target to obtain the Pareto-optimal margin in terms of adequate coverage versus increase in target volume. Main results. The percentage of treatments that reach the dose criterion V 42.75Gy > 95% for the CTV-T-LR was 22.3%, 28.5%, 51.2%, 73.1%, 85.3%, and 90.0% for 2, 3, 4, 5, 6, and 7 mm SR plus 3% RR and for the CTV-E, this percentage was 60.4%, 73.8%, 86.5%, 92.3%, 96.9%, and 98.5%. The Pareto-optimal margin combined with a 5 mm/3% robustness setting for the CTV-T-LR with an adequate coverage for >90% of the treatments was given by {0, 1, 0, 3, 3, 0} mm in the left, right, anterior, posterior, cranial, caudal direction. Significance. Our study evaluated combinations of robustness and anisotropic margin settings for IMPT for LACC. With 5 mm SR and 3% RR for CTV-E and CTV-T-LR plus a margin to the CTV-T-LR of {0, 1, 0, 3, 3, 0} mm in left, right, anterior, posterior, cranial, and caudal ensured an adequate coverage for >90% of the simulated IMPT treatments.