Victoria Messerschmidt

Victoria Messerschmidt

Auto-generated profile, based on publicly available information

Victoria Messerschmidt

Joint Department of Bioengineering, UT Arlington/UT Southwestern 1 , Arlington, Texas 76010, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2015 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
TKTimothy J. Keane
Timothy J. Keane
JDJenna Dziki
Jenna Dziki
ACArthur Castelton
Arthur Castelton
DFDenver M. Faulk
Denver M. Faulk
VMVictoria Messerschmidt
Victoria Messerschmidt
SBStephen Badylak
Stephen Badylak

15 September 2018 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
YDYichen Ding
Yichen Ding
ZBZachary Bailey
Zachary Bailey
VMVictoria Messerschmidt
Victoria Messerschmidt
JNJun Nie
Jun Nie
RBRichard Bryant
Richard Bryant
THTzung Hsiai
Tzung Hsiai
Light-sheet fluorescence microscopy has been widely used for rapid image acquisition with a high axial resolution from micrometer to millimeter scale. Traditional light-sheet techniques involve the use of a single illumination beam directed orthogonally at sample tissue. Images of large samples that are produced using a single illumination beam contain stripes or artifacts and suffer from a reduced resolution due to the scattering and absorption of light by the tissue. This study uses a dual-sided illumination beam and a simplified CLARITY optical clearing technique for the murine heart. These techniques allow for deeper imaging by removing lipids from the heart and produce a large field of imaging, greater than 10 x 10 x 10 mm3. As a result, this strategy enables us to quantify the ventricular dimensions, track the cardiac lineage, and localize the spatial distribution of cardiac-specific proteins and ion-channels from the post-natal to adult mouse hearts with sufficient contrast and resolution.

10 August 2018 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
VMVictoria Messerschmidt
Victoria Messerschmidt
ZBZachary Bailey
Zachary Bailey
KBKyung In Baek
Kyung In Baek
YDYichen Ding
Yichen Ding
JHJeffrey J. Hsu
Jeffrey J. Hsu
JLJuhyun Lee
Juhyun Lee
The hemodynamic forces experienced by the heart influence cardiac development, especially trabeculation, which forms a network of branching outgrowths from the myocardium. Genetic program defects in the Notch signaling cascade are involved in ventricular defects such as Left Ventricular Non-Compaction Cardiomyopathy or Hypoplastic Left Heart Syndrome. Using this protocol, it can be determined that shear stress driven trabeculation and Notch signaling are related to one another. Using Light-sheet Fluorescence Microscopy, visualization of the developing zebrafish heart was possible. In this manuscript, it was assessed whether hemodynamic forces modulate the initiation of trabeculation via Notch signaling and thus, influence contractile function occurs. For qualitative and quantitative shear stress analysis, 4-D (3-D+time) images were acquired during zebrafish cardiac morphogenesis, and integrated light-sheet fluorescence microscopy with 4-D synchronization captured the ventricular motion. Blood viscosity was reduced via gata1a-morpholino oligonucleotides (MO) micro-injection to decrease shear stress, thereby, down-regulating Notch signaling and attenuating trabeculation. Co-injection of Nrg1 mRNA with gata1a MO rescued Notch-related genes to restore trabeculation. To confirm shear stress driven Notch signaling influences trabeculation, cardiomyocyte contraction was further arrested via tnnt2a-MO to reduce hemodynamic forces, thereby, down-regulating Notch target genes to develop a non-trabeculated myocardium. Finally, corroboration of the expression patterns of shear stress-responsive Notch genes was conducted by subjecting endothelial cells to pulsatile flow. Thus, the 4-D light-sheet microscopy uncovered hemodynamic forces underlying Notch signaling and trabeculation with clinical relevance to non-compaction cardiomyopathy.

1 July 2020 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
TTTanveer Teranikar
Tanveer Teranikar
VMVictoria Messerschmidt
Victoria Messerschmidt
JLJessica Lim
Jessica Lim
ZBZach Bailey
Zach Bailey
J.-C. ChiaoJ.-C. Chiao
J.-C. Chiao
JLJuhyun Lee
Juhyun Lee
Light-sheet fluorescence microscopy (LSFM) provides access to multi-dimensional and multi-scale in vivo imaging of animal models with highly coherent volumetric reconstruction of the tissue morphology, via a focused laser light sheet. The orthogonal illumination and detection LSFM pathways account for minimal photobleaching and deep tissue optical sectioning through different perspective views. Although rotation of the sample and deep tissue scanning constitutes major advantages of LSFM, images may suffer from intrinsic problems within the modality, such as light mismatch of refractive indices between the sample and mounting media and varying quantum efficiency across different depths. To overcome these challenges, we hereby introduce an illumination correction technique integrated with depth detail amelioration to achieve symmetric contrast in large field-of-view images acquired using a low power objective lens. Due to an increase in angular dispersion of emitted light flux with the depth, we combined the dehazing algorithm with morphological operations to enhance poorly separated overlapping structures with subdued intensity. The proposed method was tested on different LSFM modalities to illustrate its applicability on correcting anisotropic illumination affecting the volumetric reconstruction of the fluorescently tagged region of interest.