Shuichiro Aoki

Shuichiro Aoki

Auto-generated profile, based on publicly available information

Shuichiro Aoki

Ophthalmology, The University of Tokyo, Tokyo, JPN

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2025 in Ophthalmology Glaucoma
Verified
Journal Article
Open access
KAKaho Akiyama
Kaho Akiyama
SAShuichiro Aoki
Shuichiro Aoki
SSShiroaki Shirato
Shiroaki Shirato
RSRei Sakata
Rei Sakata
MHMegumi Honjo
Megumi Honjo
HSHitomi Saito
Hitomi Saito
To evaluate the location-specific association of deep optic nerve head (ONH) structures and background characteristics with visual field (VF) sensitivity in eyes with peripapillary intrachoroidal cavitation (PICC). Prospective cross-sectional study. 129 eyes of 93 consecutive cases with PICC determined on fundus photographs and confirmed on optical coherence tomography (OCT). PICC location was determined on ONH-centered OCT radial slices according to Garway-Heath sectors. VF defect (VFD) corresponding to the location of PICC sector was considered absent when the pattern deviation probability plot showed no point with a probability less than 1% within the corresponding 24-2 Humphrey VF sector. Sectoral mean total deviation (TD) was calculated for structure-function analysis. The presence of full thickness retinal defect was determined, and PICC depth and deep ONH parameters were calculated with OCT slices. A best-fit multivariable linear mixed model was applied to identify factors associated with sectoral mean TD corresponding to PICC location. Explanatory variables included age, sex, axial length, intraocular pressure, presence of full thickness retinal defect, circumpapillary retinal nerve fiber layer thickness (cpRNFLT), PICC depth, Bruch's membrane opening (BMO) area, scleral flange opening (SFO) area and SFO/BMO offset magnitude. Among 254 sectors with PICC, 136 sectors (54%) did not present corresponding VFD. Suspected VFD was most frequent in the temporal (34/50, 68%) and inferior temporal (67/104, 64%) sectors. In the best-fit multivariable analysis, worse sectoral TD in the PICC sectors was associated with the presence of full thickness retinal defect (p=0.036) and thinner cpRNFLT (p<0.001) but was not associated with PICC depth or other deep ONH parameters. Although PICC alone did not necessarily cause corresponding VFD, PICC in the temporal sectors should be carefully examined for VFD. Full thickness retinal defect, a myopia-induced tissue disruption, and cpRNFL thinning at the PICC location were significantly associated with worse VF, while PICC size and other myopia-related deep ONH structural changes were not. Identification of these factors provides a foundation for understanding VF sensitivity reduction in eyes with characteristic highly myopic ONH changes.

6 January 2021 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
MIMasanori Iwasaki
Masanori Iwasaki
KKKenji Kobayashi
Kenji Kobayashi
SAShuichiro Aoki
Shuichiro Aoki
HMHirotomo Miyamoto
Hirotomo Miyamoto
HIHiroko Imaizumi
Hiroko Imaizumi

29 January 2024 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
SAShuichiro Aoki
Shuichiro Aoki
RARyo Asaoka
Ryo Asaoka
KAKeiko Azuma
Keiko Azuma
KKKohdai Kitamoto
Kohdai Kitamoto
KUKohei Ueda
Kohei Ueda
RORyo Obata
Ryo Obata
Purpose: Recent evidence suggests that venous congestion at the vortex vein significantly contributes to the development of central serous chorioretinopathy (CSCR), and sclera is observed to be thicker in affected eyes. This study aims to investigate whether eyes with CSCR exhibit stiff corneas, measured using Corneal Visualization Scheimflug Technology (Corvis ST), which may serve as an indicator of scleral stiffness. Methods: This retrospective case–control study comprises 52 eyes from 33 patients diagnosed with CSCR and 52 eyes from 32 normal controls without CSCR. We compared biomechanical parameters measured with Corvis ST and anterior scleral thickness measured using anterior segment swept-source optical coherence tomography between the two groups. Results: Age, sex, axial length, intraocular pressure, and central corneal thickness showed no significant differences between the two groups (p > 0.05, linear mixed model). Three biomechanical parameters—peak distance, maximum deflection amplitude, and integrated inverse radius—indicated less deformability in CSCR eyes compared to control eyes. The stress–strain index (SSI), a measure of stiffness, and anterior scleral thickness (AST) at temporal and nasal points were significantly higher in the CSCR eyes. SSI and AST were not correlated, yet both were significantly and independently associated with CSCR in a multivariate logistic regression model. Conclusions: Eyes affected by CSCR have stiffer corneas, irrespective of thicker scleral thickness. This suggests that stiffer sclera may play a role in the pathogenesis of CSCR.

2 April 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
KYKazuki Yashiro
Kazuki Yashiro
SAShuichiro Aoki
Shuichiro Aoki
KKKohdai Kitamoto
Kohdai Kitamoto
TATakahiro Arai
Takahiro Arai
KAKeiko Azuma
Keiko Azuma
RORyo Obata
Ryo Obata
Corneal biomechanical properties are associated with axial elongation. We aimed to characterize corneal biomechanical properties in highly myopic eyes with myopic maculopathy (MM). Retrospective cross-sectional study. We included patients examined between June 2022 and August 2023 who underwent corneal visualization Scheimpflug technology (Corvis ST) measurements. MM in highly myopic eyes (axial length >26.0 mm) was evaluated using META-PM (meta-analyses of pathologic myopia) study classification based on fundus photographs with subfoveal choroidal thickness measured via spectral domain optical coherence tomography. A linear mixed model was used to analyze the association of MM features with axial length (AL) and corneal biomechanical parameters, followed by model selection using the second-order-corrected Akaike information criterion. We included 189 eyes from 109 participants. A significant correlation was observed between AL and biomechanical parameters that characterize maximal corneal deformation (maximal deflection amplitude and peak distance) and stiffness parameter (stress-strain index) (P < .05). Model selection revealed that both AL and maximal deflection amplitude were independently associated with MM with category ≥2 severe, as well as with subfoveal choroidal thickness in highly myopic eyes (AL >26.0 mm). In highly myopic eyes, a greater maximal deflection amplitude was identified as a risk factor for MM. Corneal biomechanical properties may serve as biomarkers for predicting the development and progression of MM.

22 August 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SSSayaka Sumi
Sayaka Sumi
RARyo Asaoka
Ryo Asaoka
SAShuichiro Aoki
Shuichiro Aoki
KKKohdai Kitamoto
Kohdai Kitamoto
RTRyo Terao
Ryo Terao
KAKeiko Azuma
Keiko Azuma
Purpose: To investigate whether corneal biomechanical parameters measured via Corvis ST can predict acute intraocular pressure (IOP) elevation following intravitreal anti-VEGF injection. Design: Retrospective observational study. Subjects: Forty eyes from patients with neovascular age-related macular degeneration or retinal vein occlusion who underwent anti-VEGF therapy. Methods: IOP was measured using the Corvis ST immediately before and 10 minutes after injection. The following biomechanical parameters were evaluated: DA Ratio MAX (2mm), biomechanically corrected IOP (bIOP), Peak Distance, Deflection Amplitude Max, Integrated Radius, and Stress-Strain Index (SSI). Main outcome measures: Acute post-injection IOP elevation (continuous) and IOP spikes ≥10 mmHg (binary). Results: The mean IOP increased significantly from 14.5 ± 3.17 to 24.7 ± 7.44 mmHg post-injection (p < 0.0001). IOP spikes ≥10 mmHg occurred in 55% of eyes. On multivariate analysis, higher bIOP (β = +1.17, p = 0.048) and lower DA Ratio MAX (β = –5.40, p = 0.038) were independent predictors of IOP elevation. DA Ratio MAX was the only significant predictor of IOP spikes (OR = 0.70, 95% CI: 0.51–0.96, p = 0.035). ROC analysis showed that DA Ratio MAX alone (AUC = 0.739) outperformed bIOP (AUC = 0.607), with the combined model yielding the highest AUC (0.773). A cutoff of DA Ratio MAX ≤4.936 provided 81.8% sensitivity and 42.9% specificity for predicting spikes. Conclusions: DA Ratio MAX (2mm), reflecting global ocular compliance, was a significant predictor of acute IOP spikes after anti-VEGF injection. Alongside bIOP, it may be useful for pre-injection risk stratification of pressure-related complications.

5 September 2022 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
PDF file
SAShuichiro Aoki
Shuichiro Aoki
HIHiroko Imaizumi
Hiroko Imaizumi
Background: Peripapillary intrachoroidal cavitation (PICC), a cavernous change in the peripapillary choroid, may present with macular lesions. Here, we present a rare case of PICC with outer lamellar macular hole and macular retinoschisis.Case presentation: A 69-year-old man presented with metamorphopsia in the left eye. Fundus examination revealed macular retinoschisis and PICCs. Pars plana vitrectomy with fovea sparing internal limiting membrane peeling (FSIP) was performed. Three weeks postoperatively, the patient developed rhegmatogenous retinal detachment and underwent a second vitrectomy. The macular retinoschisis resolved without macular hole formation and the patient’s visual acuity improved. There were no recurrent macular lesions over the three years of postoperative follow-up. Postoperative spectral-domain optical coherence tomography scan revealed a communication between the PICC and the vitreous cavity.Conclusions: This case shed light on understanding development of PICC in non-highly myopic eyes and a rare complication of macular retinoschisis. Vitrectomy with FSIP may effectively resolve macular retinoschisis.