9 August 2021 in IEEE Transactions on Nuclear Science
In the nuclear sciences and radiation detection fields, the differentiation between gamma-ray and neutron interactions inside a detector volume continues to be an area of active research. Historically, the primary mechanism for conducting particle identification has been pulse shape discrimination (PSD). However, almost all variations of this technique rely on only two factors: the area of the tail and the total area of the pulse. In the last decade, the emergence of advanced machine learning techniques, most specifically artificial neural networks (ANNs), offers a unique opportunity to capitalize on the entirety of the waveform. But such techniques appear highly reliant on the quality of datasets used for training. Our research addresses this challenge to quantify the relative performances of networks trained on a variety of datasets and subjected to the same test. Furthermore, we offer an analysis of the portability of a network trained on one detector to a similar detector.
1 November 2018 in Health Physics
Proper characterization of 137Cs sources used for dosimeter calibration and performance testing is crucial for accurate and precise knowledge of air kerma rate and delivered dose. A 269 GBq 137Cs source was relocated to a new facility, which had a footprint of approximately 2.8 m × 3.6 m and a 3.4 m high ceiling. A small room size, such as in the new facility, may significantly increase backscatter from the walls or room return. Due to the limited source strength, a relatively close irradiation position of 1.00 m from the source was selected to decrease required exposure times. Proximity to the small but cylindrical source has the potential to alter the 1/r 2 relationship (inverse square law) of air kerma rate with distance associated with point sources. Practical tutorials concerning dosimetry irradiation facilities are largely absent from the archival literature. For those reasons, standard characterization experiments were repeated multiple times, great care was taken with positioning, several experiments were added to the standard ones, an ion chamber and dosimeters were used rather than film for greater accuracy and precision, and practical details of the process were recorded. The impacts of room size and finite source dimensions were quantified and mitigated by the efforts reported here. Recommendations for simple but thorough facility characterization, beam calibration, and quality control resulted.
4 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
2 June 2025 in Astroparticle Physics
24 January 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 January 2026 in Journal of Instrumentation
LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.