Andrew S. Wilhelm

Andrew S. Wilhelm

Auto-generated profile, based on publicly available information

Andrew S. Wilhelm

Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, U.S.A.

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
DFDavid Fobar
David Fobar
LPLogan Phillips
Logan Phillips
AWAndrew Wilhelm
Andrew Wilhelm
PCPeter Chapman
Peter Chapman
In the nuclear sciences and radiation detection fields, the differentiation between gamma-ray and neutron interactions inside a detector volume continues to be an area of active research. Historically, the primary mechanism for conducting particle identification has been pulse shape discrimination (PSD). However, almost all variations of this technique rely on only two factors: the area of the tail and the total area of the pulse. In the last decade, the emergence of advanced machine learning techniques, most specifically artificial neural networks (ANNs), offers a unique opportunity to capitalize on the entirety of the waveform. But such techniques appear highly reliant on the quality of datasets used for training. Our research addresses this challenge to quantify the relative performances of networks trained on a variety of datasets and subjected to the same test. Furthermore, we offer an analysis of the portability of a network trained on one detector to a similar detector.

1 November 2018 in Health Physics
Verified
Journal Article
Closed access
JMJasmine L. Mapes
Jasmine L. Mapes
KLKevin Liu
Kevin Liu
SASara A. Abraham
Sara A. Abraham
AWAndrew S. Wilhelm
Andrew S. Wilhelm
LLLogan V. Latosz
Logan V. Latosz
KKKimberlee J. Kearfott
Kimberlee J. Kearfott
Proper characterization of 137Cs sources used for dosimeter calibration and performance testing is crucial for accurate and precise knowledge of air kerma rate and delivered dose. A 269 GBq 137Cs source was relocated to a new facility, which had a footprint of approximately 2.8 m × 3.6 m and a 3.4 m high ceiling. A small room size, such as in the new facility, may significantly increase backscatter from the walls or room return. Due to the limited source strength, a relatively close irradiation position of 1.00 m from the source was selected to decrease required exposure times. Proximity to the small but cylindrical source has the potential to alter the 1/r 2 relationship (inverse square law) of air kerma rate with distance associated with point sources. Practical tutorials concerning dosimetry irradiation facilities are largely absent from the archival literature. For those reasons, standard characterization experiments were repeated multiple times, great care was taken with positioning, several experiments were added to the standard ones, an ion chamber and dosimeters were used rather than film for greater accuracy and precision, and practical details of the process were recorded. The impacts of room size and finite source dimensions were quantified and mitigated by the efforts reported here. Recommendations for simple but thorough facility characterization, beam calibration, and quality control resulted.

4 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
AWAndrew S. Wilhelm
Andrew S. Wilhelm
IJIgor Jovanovic
Igor Jovanovic

2 June 2025 in Astroparticle Physics
Verified
Journal Article
Open access
SSS.R. Soleti
S.R. Soleti
JGJ.J. Gómez-Cadenas
J.J. Gómez-Cadenas
JAJ. Apilluelo
J. Apilluelo
LAL. Asquith
L. Asquith
EBE.F. Bannister
E.F. Bannister
FYF. Yermia
F. Yermia

24 January 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
AWAndrew S. Wilhelm
Andrew S. Wilhelm
GWGarrett Wendel
Garrett Wendel
BCBrandon Collins
Brandon Collins
DCDoug Cowen
Doug Cowen
IJIgor Jovanovic
Igor Jovanovic

1 January 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
JAJ. Apilluelo
J. Apilluelo
LAL. Asquith
L. Asquith
EBE.F. Bannister
E.F. Bannister
NBN.P. Barradas
N.P. Barradas
CBC.L. Baylis
C.L. Baylis
FYF. Yermia
F. Yermia
LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.