10 August 2016 in IEEE Transactions on Industry Applications
For a microgrid with a mix of distributed energy resources (DERs), major challenges on its survivability are found in the islanded condition. In particular, a sudden loss of generation or a large and fluctuating load could force the microgrid to operate near its capacity limits. Such a situation can cause a cascading collapse of the mixed-source microgrid, even when the load demand is within the system's power rating. This condition was observed during several tests carried out at the Consortium for Electric Reliability Technology Solutions Microgrid Test Bed. This paper analyzes the root causes behind the collapse. It highlights that the capacity of a low-inertia system to support load changes is contributed by faster responding DERs initially. Therefore, the microgrid is particularly susceptible if the faster responding DERs do not have adequate reserve margin. Two control methods are evaluated for providing safeguards to these DERs and prevent the system collapse.
9 March 2021 in IEEE Transactions on Industry Applications
The reactive power capability of distributed photovoltaic (PV) inverters could be exploited to mitigate voltage violations under high PV penetration in the distribution grid. Coordinating the reactive power dispatch of individual PV inverters to obtain desired voltage regulation performance is a major challenge. In this paper, a decentralized method is proposed to enable PV inverters to autonomously regulate terminal node voltages. The proposed method minimizes the effect of a terminal node's reactive power contribution on the voltage profile of its respective parent-to-terminal node. This ensures that the interference between the voltage regulation of terminal nodes by individual PV inverters is minimized. The performance of the proposed decentralized scheme is verified by extensive powerflow simulations on the EPRI Circuit 24 test feeder in open-source distribution system simulation platform OpenDSS.
24 January 2017 in IEEE Transactions on Industry Applications
Microgrids with increased penetration of renewables experience serious challenges due to large frequency excursions under power system disturbances. An energy storage system can provide frequency regulation, but the effectiveness depends on whether it is configured for the grid-forming or grid-following mode of operation. For this purpose, two critical parameters are studied for frequency regulation in distribution systems; first, the initial rate-of-change-of-frequency (ROCOF), and second, the minimum value of frequency, also known as frequency nadir, following a load change. The aim of this paper is to identify analytical methods for accurately calculating the frequency parameters like ROCOF and frequency nadir. Reduced-order models are developed to determine the frequency deviation against power system disturbances. The results are verified against simulation models validated by testing at the Consortium for Electric Reliability Technology Solutions Microgrid test bed.
10 July 2018 in IEEE Transactions on Industry Applications
Power electronic converter-interfaced distributed energy resources (DERs) are being increasingly deployed for achieving high energy efficiency, power quality, and flexibility of power system operation and controls. They facilitate access to a wide array of energy sources including renewables, fuel cells, microturbines, variable speed engine-generator sets, etc. However, recent tests carried out at the Consortium of Electric Reliability Technology Solutions (CERTS) Microgrid have indicated that their deployment in the mixed source microgrid can cause a cascading collapse during extreme events. Simulation models of two types of DERs are developed in PSCAD/EMTDC software and validated with the experimental test results. The validated models are used to study a cascading collapse problem in a large-scale mixed source microgrid on the benchmark IEEE 33-bus test system. This paper evaluates three alternative techniques to prevent the cascading collapse in the large-scale microgrid caused by fast-acting inverter-based DERs.
26 May 2022 in IEEE Transactions on Industry Applications
This article proposes a generalized energy storage model for battery energy storage systems, electric water heaters (EWH), and heating, ventilation, and air-conditioning (HVAC) systems to enable demand response control complying to Energy Star and CTA-2045 standards. The demand response control has been implemented in the DER integration testbed, which was originally developed by Electric Power Research Institute, to demonstrate that the “energy content” and “energy take” for BESS and EWH with mixing valve technology are comparable for typical residential ratings. A distribution power system was modeled using the modified IEEE 123-bus feeder system, measured residential loads, and EWH power simulated based on realistic hot water draws from CBECC-Res software. The demand response control, which complies to CTA-2045 standards was implemented to the EWHs considering the energy take values. Results demonstrate that the EWHs can be controlled to postpone the peak power at the distribution system level and provide a large amount of energy storage, while maintaining system robustness. The impact on occupant comfort was also analyzed.