Kalotina Geraki

Kalotina Geraki

Auto-generated profile, based on publicly available information

Kalotina Geraki

Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE, UK

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
ABAnouk Margaretha Borst
Anouk Margaretha Borst
Martin  SmithMartin Smith
Martin Smith
AFAdrian A. Finch
Adrian A. Finch
GEGuillaume Estrade
Guillaume Estrade
Cristina Villanova-de-BenaventCristina Villanova-de-Benavent
Cristina Villanova-de-Benavent
KGKalotina Geraki
Kalotina Geraki
Global resources of heavy Rare Earth Elements (REE) are dominantly sourced from Chinese regolith-hosted ion-adsorption deposits in which the REE are inferred to be weakly adsorbed onto clay minerals. Similar deposits elsewhere might provide alternative supply for these high-tech metals, but the adsorption mechanisms remain unclear and the adsorbed state of REE to clays has never been demonstrated in situ. This study compares the mineralogy and speciation of REE in economic weathering profiles from China to prospective regoliths developed on peralkaline rocks from Madagascar. We use synchrotron X-ray absorption spectroscopy to study the distribution and local bonding environment of Y and Nd, as proxies for heavy and light REE, in the deposits. Our results show that REE are truly adsorbed as easily leachable 8- to 9-coordinated outer-sphere hydrated complexes, dominantly onto kaolinite. Hence, at the atomic level, the Malagasy clays are genuine mineralogical analogues to those currently exploited in China.

18 June 2002 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
KGK Geraki
K Geraki
MFM J Farquharson
M J Farquharson
DBD A Bradley
D A Bradley
An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty samples were measured in total. Twenty samples were matched pairs, i.e. 20 tumour samples with 20 corresponding healthy tissue specimens taken at a distance from the tumour. The remaining 40 samples consisted of 20 excised tumours and 20 healthy specimens from breast reduction surgeries. The levels of the elements of interest were quantified via calibration models constructed using the XRF response from standard solutions. The statistical analysis of the results indicates elevation of the levels of all three trace elements in the tumours. The effect is more prominent for copper and zinc while the contrast between healthy and diseased tissue is enhanced when comparing the independent specimens rather than the paired samples. Specifically, the ratio of mean tumour to mean healthy concentration for iron was 1.6 for the paired samples and 2.7 for the non-paired samples. The ratios describing copper content were 3.1 for paired and 3.6 for non-paired samples while for zinc they were 2.4 and 4.4 respectively.

24 March 2015 in Minerals
Verified
Journal Article
Open access
PDF file
Nigel CookNigel Cook
Nigel Cook
BEBarbara Etschmann
Barbara Etschmann
CCCristiana Ciobanu
Cristiana Ciobanu
KGKalotina Geraki
Kalotina Geraki
DHDaryl L. Howard
Daryl L. Howard
JBJoël Brugger
Joël Brugger
The distribution and substitution mechanism of Ge in the Ge-rich sphalerite from the Tres Marias Zn deposit, Mexico, was studied using a combination of techniques at μm- to atomic scales. Trace element mapping by Laser Ablation Inductively Coupled Mass Spectrometry shows that Ge is enriched in the same bands as Fe, and that Ge-rich sphalerite also contains measurable levels of several other minor elements, including As, Pb and Tl. Micron- to nanoscale heterogeneity in the sample, both textural and compositional, is revealed by investigation using Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) combined with Synchrotron X-ray Fluorescence mapping and High-Resolution Transmission Electron Microscopy imaging of FIB-prepared samples. Results show that Ge is preferentially incorporated within Fe-rich sphalerite with textural complexity finer than that of the microbeam used for the X-ray Absorption Near Edge Structure (XANES) measurements. Such heterogeneity, expressed as intergrowths between 3C sphalerite and 2H wurtzite on zones, could be the result of either a primary growth process, or alternatively, polystage crystallization, in which early Fe-Ge-rich sphalerite is partially replaced by Fe-Ge-poor wurtzite. FIB-SEM imaging shows evidence for replacement supporting the latter. Transformation of sphalerite into wurtzite is promoted by (111)* twinning or lattice-scale defects, leading to a heterogeneous ZnS sample, in which the dominant component, sphalerite, can host up to ~20% wurtzite. Ge K-edge XANES spectra for this sphalerite are identical to those of the germanite and argyrodite standards and the synthetic chalcogenide glasses GeS2 and GeSe2, indicating the Ge formally exists in the tetravalent form in this sphalerite. Fe K-edge XANES spectra for the same sample indicate that Fe is present mainly as Fe2+, and Cu K-edge XANES spectra are characteristic for Cu+. Since there is no evidence for coupled substitution involving a monovalent element, we propose that Ge4+ substitutes for (Zn2+, Fe2+) with vacancies in the structure to compensate for charge balance. This study shows the utility of synchrotron radiation combined with electron beam micro-analysis in investigating low-level concentrations of minor metals in common sulfides.

15 December 2003 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
KGK Geraki
K Geraki
MFM J Farquharson
M J Farquharson
DBD A Bradley
D A Bradley
This paper presents improvements on a previously reported method for the measurement of elements in breast tissue specimens (Geraki et al 2002 Phys. Med. Biol. 47 2327-39). A synchrotron-based system was used for the detection of the x-ray fluorescence (XRF) emitted from iron, copper, zinc and potassium in breast tissue specimens, healthy and cancerous. Calibration models resulting from the irradiation of standard aqueous solutions were used for the quantification of the elements. The present developments concentrate on increasing the convergence between the tissue samples and the calibration models, therefore improving accuracy. For this purpose the composition of the samples in terms of adipose and fibrous tissue was evaluated, using an energy dispersive x-ray diffraction (EDXRD) system. The relationships between the attenuation and scatter properties of the two tissue components and water were determined through Monte Carlo simulations. The results from the simulations and the EDXRD measurements allowed the XRF data from each specimen to be corrected according to its composition. The statistical analysis of the elemental concentrations of the different groups of specimens reveals that all four elements are found in elevated levels in the tumour specimens. The increase is less pronounced for iron and copper and most for potassium and zinc. Other observed features include the substantial degree of inhomogeneity of elemental distributions within the volume of the specimens, varying between 4% and 36% of the mean, depending on the element and the type of the sample. The accuracy of the technique, based on the measurement of a standard reference material, proved to be between 3% and 22% depending on the element, which presents only a marginal improvement (1%-3%) compared to the accuracy of the previously reported results. The measurement precision was between 1% and 9% while the calculated uncertainties on the final elemental concentrations ranged between 10% and 16%.

1 June 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SDSofia Diaz-Moreno
Sofia Diaz-Moreno
MAMonica Amboage
Monica Amboage
MBMark Basham
Mark Basham
RBRoberto Boada
Roberto Boada
NBNicolas E. Bricknell
Nicolas E. Bricknell
SPStephen Parry
Stephen Parry
This manuscript presents the current status and technical details of the Spectroscopy Village at Diamond Light Source. The Village is formed of four beamlines: I18, B18, I20-Scanning and I20-EDE. The village provides the UK community with local access to a hard X-ray microprobe, a quick-scanning multi-purpose XAS beamline, a high-intensity beamline for X-ray absorption spectroscopy of dilute samples and X-ray emission spectroscopy, and an energy-dispersive extended X-ray absorption fine-structure beamline. The optics of B18, I20-scanning and I20-EDE are detailed; moreover, recent developments on the four beamlines, including new detector hardware and changes in acquisition software, are described.

1 October 2014 in Geology
Verified
Journal Article
Closed access
PDF file
SCSara Callegaro
Sara Callegaro
DBDon R Baker
Don R Baker
AMAngelo De Min
Angelo De Min
AMAndrea Marzoli
Andrea Marzoli
KGKalotina Geraki
Kalotina Geraki
FNFabrizio Nestola
Fabrizio Nestola
Volcanic gases can have devastating impacts on Earth’s environment and life. However, measurement of volatile elements in prehistoric magmas is challenging. We present a new method for determining sulfur contents in magmas using its concentrations in clinopyroxenes and an experimentally determined crystal-melt partition coefficient. Using this method we compared magmatic sulfur contents in the Paraná-Etendeka large igneous province (LIP; South America) and two other similarly sized LIPs, the Central Atlantic magmatic province (CAMP) and the Deccan Traps (India). We found that the CAMP and Deccan Traps, both associated with major extinction events, contained high magmatic sulfur concentrations, up to 1900 ppm. Conversely, the Paraná-Etendeka LIP, lacking significant environmental effects, had substantially lower magmatic sulfur concentrations, less than 800 ppm.