Limited and non-regulated emissions of scooters were analysed during several annual research programs of the Swiss Federal Office of Environment (BAFU) *). Small scooters, which are very much used in the congested centers of several cities, are a remarkable source of air pollution. Therefore every effort to reduce the emissions is an important contribution to improve the air quality in urban centers. In the present work detailed investigations of particle emissions of different 2-stroke scooters with direct injection and with carburettor were performed. The nanoparticulate emissions were measured by means of SMPS, (CPC) and NanoMet. Also the particle mass emission (PM) was measured with the same method as for Diesel engines. Extensive analyses of PM-residuum for SOF/INSOF, PAH and toxicity equivalence (TEQ), were carried out in an international project network. Particle mass emission (PM) of 2-S Scooters consists mostly of SOF. The standard coulometric EC/OC-analysis, as well as the analyzer MEXA 1370 PM overestimate the amount of soot due to the effect of “charring”, which provokes the heaviest VOC to stay in the sample during the thermal extraction and to be indicated as EC. A solution for this analytical problem is demonstrated. Wiremash Filter Catalyst (WFC) is en efficient measure to intensify the oxidation of the exhaust gas components and to reduce PM, PC, PAH, TEQ & VOC. The presented WFC needs a further development for durability and product integration. The amount of total PAH, as well as the toxicity equivalence factor TEQ correlate roughly with the total particle mass PM. WFC is an efficient aftertreatment measure to substancially lower the toxicity of 2-S exhaust gases.
1 November 2017 in Revista Española de Anestesiología y Reanimación
Introducción: La neuromodulación de las raíces sacras se ha mostrado eficaz en el tratamiento del dolor pélvico crónico (DPC) refractario a tratamiento farmacológico. En estos pacientes, parece existir un importante grado de sensibilización central. La radiofrecuencia pulsada ha demostrado su utilidad en múltiples cuadros de dolor neuropático. Una modificación de la técnica de radiofrecuencia pulsada (RFP) vía caudal, propuesta por Rohof para el tratamiento de pacientes con sensibilización central, intentando concentrar los impulsos electromagnéticos sobre las vías nerviosas aferentes y eferentes que inervan las distintas estructuras pélvicas, quizá pudiera ser efectiva en el tratamiento de estos pacientes. En este artículo se presentan dos pacientes con DPC refractario a otros tratamientos previos que han respondido adecuadamente a la RFP vía caudal de raíces sacras. Material y métodos: Se presentan dos casos de pacientes con DPC con escasa respuesta previa a distintos tratamientos conservadores e intervencionistas clásicos. Se realiza RFP vía caudal de raíces sacras, con una cánula recta, con control de temperatura (electrodo extraíble Cosman® modelo CC152020) situando su punta, mediante control radiológico, a nivel S3 y colocando la placa dispersiva sobre la unión sacro lumbar. Tras la RFP se realiza inyección posterior de anestésico local y corticoide a través de la cánula. Se evalúa a los pacientes cada tres meses hasta el momento actual. Resultados: Tras la aplicación de esta técnica, ambos pacientes refieren disminución de la intensidad del dolor en la escala NRS (de 8-9/10 a 2-3/10), así como un grado de alivio de hasta el 80 %, afirmando haber obtenido con esta técnica el mayor grado de satisfacción logrado hasta el momento con una mayor duración del mismo. Conclusión: La RFP de raíces sacras vía caudal puede suponer una nueva, sencilla, útil y segura alternativa terapéutica en pacientes con DPC.
1 January 2018 in Revista de la Sociedad Española del Dolor