Leya Roshani Kober

Leya Roshani Kober

Auto-generated profile, based on publicly available information

Leya Roshani Kober

University of Toronto

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Renewable Energy
Verified
Journal Article
Closed access
SNSarah R. Nicholson
Sarah R. Nicholson
LKLeya R. Kober
Leya R. Kober
PAPedram Atefrad
Pedram Atefrad
AMAggrey Mwesigye
Aggrey Mwesigye
SDSeth B. Dworkin
Seth B. Dworkin

8 September 2025 in Advanced Science
Verified
Journal Article
Open access
CHChaeyoung T. Ham
Chaeyoung T. Ham
PSPranay Shrestha
Pranay Shrestha
LKLeya Kober
Leya Kober
SGSergey Gasilov
Sergey Gasilov
AWAdam Webb
Adam Webb
ABAimy Bazylak
Aimy Bazylak
In this study, the effects of operating temperature on pore‐scale gas bubble transport in a carbon‐based anode porous transport layer (PTL) of a polymer electrolyte membrane (PEM) electrolyzer is revealed using operando X‐ray computed tomography (CT). Higher temperature operation (80 °C compared to 40 °C) led to a lower total gas bubble volume fraction in the PTL (0.25 to 0.17; 32% lower), which is attributed to improved water transport and gas removal. Higher temperatures led to fewer bubbles in the PTL (13% less at 80 °C compared to 40 °C) as well as a greater occurrence of smaller bubbles (35% increase in skewness of the bubble size distribution), and this behavior is attributed to faster rates of nucleation and bubble detachment from the electrode. The formation of gas slugs is also observed in the anode channels at 60 °C and 80 °C, which is attributed to the faster detachment and coalescence of bubbles from the PTL/flow field interface.


9 October 2022 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
LKLeya Roshani Kober
Leya Roshani Kober
PSPranay Shrestha
Pranay Shrestha
CHChaeyoung Tina Ham
Chaeyoung Tina Ham
ABAimy Bazylak
Aimy Bazylak
The intermittent nature of many renewable energy sources, such as solar and wind, presents the need to acquire on-demand renewable energy either through energy storage or energy production methods. The polymer electrolyte membrane (PEM) fuel cell is quickly becoming an attractive solution as it can produce high power densities under a rapid change in load while producing zero local carbon emissions [1] and is ideal for large-scale applications, such as automotive [2]. However, barriers to their widespread implementation are attributed to the high costs associated with mass transport losses at high current density operation due to inefficiencies in liquid water management in the gas diffusion layer (GDL) [3][4]. Understanding the relationship between liquid water distributions in the cathode GDL and transport properties of PEM fuel cells under varying operating conditions can lead to improved GDL configurations for improved performance. Previously, studies have been conducted to characterize the effect of operating temperature on liquid water pathways in GDLs by using 3D imaging techniques on operando PEM fuel cells [5]. High-speed, high-resolution 3D imaging techniques, such as computed tomography (CT), enable the visualization of dynamic pore-scale effects and are advantageous in elucidating transport mechanisms in the GDL. In this work, the effect of operating relative humidity on the formation of liquid water pathways in the GDL will be explored by imaging an operando PEM fuel cell with synchrotron X-ray CT. To date, a custom PEM fuel cell has been developed in-house which features a novel design with two rotary unions on either side of the cell. The rotary unions enable continuous rotation of the cell during imaging, and thus are central to achieving high temporal resolution for visualizing the development of preferential water pathways. High spatial resolution (pixel resolution of 1.44 microns per pixel [6]) is also obtained with the synchrotron beam, which allows for the visualization of liquid water in individual pores at the microscale in the GDL. Visualizing water in the micropores of the GDL can help us further understand water transport mechanisms within the complex structure of the GDL to ultimately develop methods to expel excess water efficiently. In the next steps of this research, we will use the results from electrochemical testing and the reconstructed images of the fuel cell to draw important conclusions about the relationship between liquid water distributions in the GDL and fuel cell performance. As well, the effect that operating relative humidity has on this relationship will be determined. The aim of this work is to inform optimal design for GDL materials for improved PEM fuel cell performance, which will ultimately accelerate their utilization on a global scale as a reliable and sustainable energy source. [1] P. Shrestha, CH. Lee, K. F. Fahy, M. Balakrishnan, N. Ge, and A. Bazylak, “Formation of Liquid Water Pathways in PEM Fuel Cells: A 3-D Pore-Scale Perspective,” Journal of The Electrochemical Society, vol. 167, no. 5, p. 054516, Jan. 2020, doi: 10.1149/1945-7111/ab7a0b. [2] S. Park, J. W. Lee, and B. N. Popov, “A review of gas diffusion layer in PEM fuel cells: Materials and designs,” International Journal of Hydrogen Energy, vol. 37, no. 7, pp. 5850– 5865, Apr. 2012, doi: 10.1016/J.IJHYDENE.2011.12.148. [3] Y. Nagai et al., “Improving water management in fuel cells through microporous layer modifications: Fast operando tomographic imaging of liquid water,” Journal of Power Sources, vol. 435, p. 226809, Sep. 2019, doi: 10.1016/J.JPOWSOUR.2019.226809. [4] U. U. Ince et al., “3D classification of polymer electrolyte membrane fuel cell materials from in situ X-ray tomographic datasets,” International Journal of Hydrogen Energy, vol. 45, no. 21, pp. 12161–12169, Apr. 2020, doi: 10.1016/J.IJHYDENE.2020.02.136. [5] Hong Xu, Shinya Nagashima, Hai P. Nguyen, Keisuke Kishita, Federica Marone, Felix N. Büchi, Jens Eller, Temperature dependent water transport mechanism in gas diffusion layers revealed by subsecond operando X-ray tomographic microscopy, Journal of Power Sources, Volume 490, 2021, 229492, ISSN 0378-7753, https://doi.org/10.1016/j.jpowsour.2021.229492. [6] Canadian Light Source, “Detectors,” BMIT. [Online]. Available: https://bmit.lightsource.ca/tech-info/detectors/. [Accessed: 05-Apr-2022].

9 October 2022 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
CHChaeyoung Tina Ham
Chaeyoung Tina Ham
PSPranay Shrestha
Pranay Shrestha
LKLeya Roshani Kober
Leya Roshani Kober
ABAimy Bazylak
Aimy Bazylak
Mass transport losses in polymer electrolyte membrane (PEM) electrolyzers are predominantly caused by the accumulation of oxygen gas within the pores of the porous transport layer (PTL), hindering reactant water delivery to reaction sites (1). To enhance mass transport and optimize electrolyzer performance, a comprehensive understanding of the mechanisms driving oxygen gas transport in the PTL is required. Numerous studies have utilized various imaging techniques - including optical, neutron, and X-ray radiography to elucidate the evolution and transport of oxygen gas in the multiphase flow regime during PEM electrolyzer operation (2). However, these techniques only capture two-dimensional (2D) images, resolving average gas distributions rather than a holistic pore-scale quantification. Few studies have used three-dimensional (3D) imaging to resolve the dynamic microscale distributions of oxygen gas in the PTL. Understanding the impact of key parameters affecting 3D oxygen gas transport, such as PTL morphology, will allow for tailored pore-scale material optimization for enhanced gas transport and improved performance of PEM electrolyzers. This study presents a non-destructive operando imaging approach using X-ray computed tomography (CT), enabling the visualization of transient 3D oxygen gas evolution and transport in the PTL of a PEM electrolyzer. Using state-of-the-art synchrotron X-rays, high temporal and spatial resolutions were achieved to capture the pore-scale formation and growth of oxygen gas pathways within the PTL at various operating conditions. Electrochemical performance of an in-house designed electrolyzer cell was also characterized while acquiring tomographic images to investigate the impact of observed transport mechanisms on performance. The methodology presented in this work showcases the capability of using X-ray CT to visualize the complex interfacial multiphase flow in PTLs. Findings from this study will provide valuable insight towards pore-scale material optimization of clean energy porous materials aimed at curtailing the costs of green hydrogen production. References 1. M. Suermann, T. J. Schmidt, and F.N. Büchi, ECS Trans., 69(17), 1141-1148 (2015). 2. M. Maier, K. Smith, J. Dodwell, G. Hinds, P. R. Shearing, and D. J. L. Brett, Int. J. Hydrog. Energy., 47(1), 30-56 (2022).