Mehmet Ci̇ngi̇rt

Mehmet Ci̇ngi̇rt

Auto-generated profile, based on publicly available information

Mehmet Ci̇ngi̇rt

RİZE PUBLIC HEALTH LABORATORY

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2022 in Archives of Current Medical Research
Verified
Journal Article
Closed access
PDF file
AYAydın YAVUZ
Aydın YAVUZ
HGHüseyin Göbüt
Hüseyin Göbüt
ÇBÇağrı Büyükkasap
Çağrı Büyükkasap
KDKürşat Dikmen
Kürşat Dikmen
HBHasan Bostanci
Hasan Bostanci
ADAydın DALGIÇ
Aydın DALGIÇ
Background: The regeneration capacity of liver tissue after partial hepatectomy closely affects morbidity and mortality. We aimed to investigate the effect of silymarin and ischemic preconditioning (IPC) before partial hepatectomy on liver regeneration. Methods: Thirty rats were randomly divided into 5 groups (n=6). Serum AST, bilirubin, tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6) values were studied 48 hours after hepatectomies. Mitotic count, congestion, necrosis, cytoplasmic vacuolization, and presence of neutrophils were evaluated histopathologically. Proliferating cell nuclear antigen (PCNA) antibody was studied immunohistochemically. Results: The AST value (2071.5±938.4) was the highest in the partial hepatectomy (PH) group. The Ischemic Preconditioning Partial Hepatectomy Group (IPC) (1535.5±204.8) and the Silymarin+Partial Hepatectomy Group (Silymarin group) (1192.3±526.3) had lower levels of AST values; however, the AST values were the lowest in the Silymarin+Ischemic Preconditioning+ Partial Hepatectomy Group (IPC+ Silymarin group) (1002.8±348.9). Likewise, the highest improvement in bilirubin levels was observed in the IPC+ Silymarin group (0.33±0.11). IL-6 (11.54±2.89) and TNF-α (39.2±22.73) values were the lowest in the IPC group, and interestingly, both were higher in the silymarin-treated groups. It was observed that these values increased in Silymarin group and IPC+ Silymarin group who received silymarin treatment compared to PH group and IPC group who did not receive silymarin. In histopathological analysis, it was found that the mitosis rate and PCNA percentage were higher in the Silymarin and IPC+ Silymarin groups. Conclusions: The use of silymarin before hepatectomy and IPC during partial hepatectomy increase liver regeneration.

21 April 2025 in Ahi Evran Medical Journal
Verified
Journal Article
Open access
PDF file
EYEsra Yılmaz
Esra Yılmaz
MAMedeni ARPA
Medeni ARPA
BŞBayram Şen
Bayram Şen
MÇMehmet Çingirt
Mehmet Çingirt
Purpose: Blood glucose measurement is of great importance in preventing complications and reducing mortality and morbidity for several diseases. Glucometers are used by any healthcare professionals. We conducted this study to show the compatibility between glucometers and autoanalyzers as a basis for hospital procurement. Materials and Methods: Fourty seven venous samples were used. Correlation, Passing Bablok regression analysis, and Bland-Altman difference plot were used to evaluate the results (glucometers and autoanalyzer). Clarke Error Grid analysis was used to assess the clinical agreement (p<0.05). Results: The correlation coefficient for G1 was 0.9294 (p<0.001; 95% CI: 0.8761-0.9603) and 0.9473 (p<0.001; 95% CI: 0.9069-0.9705) for G2. Regression equations were G1 y=1.1235x+3.4662 G2 y=0.8846x+10.0076. In Clarke Error Grid analysis, the criterion of 99% of the data being in zone A or B was met for both glucometers. Conclusion: According to the relevant document, based on the result obtained with the reference method as the target value, 95% of all results less than 100 mg/dl should be within ±12 mg/dl of the target value. 95% of all results above 100 mg/dl should be within ±12.5% of the target value. In addition, the ratio of the sum of results less than 75 mg/dl exceeding ±15 mg/dl and results greater than 75 mg/dl exceeding ±20% of the target value to all results should be less than 2%. Glucometers didn’t fully meet the performance targets. We think that glucometer analysis results should be closely monitored and verified after procurement.