Fred van Nijnatten

Fred van Nijnatten

Auto-generated profile, based on publicly available information

Fred van Nijnatten

Image Guided Therapy, Philips Healthcare, Best, Noord-Brabant, The Netherlands

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2012 in Medical Physics
Verified
Journal Article
Closed access
OBOdile Bonnefous
Odile Bonnefous
VPVitor Mendes Pereira
Vitor Mendes Pereira
RORafik Ouared
Rafik Ouared
OBOlivier Brina
Olivier Brina
HAHans Aerts
Hans Aerts
DRDaniel Ruijters
Daniel Ruijters

6 January 2020 in International Journal of Stroke
Verified
Journal Article
Open access
PDF file
MBMehdi Bouslama
Mehdi Bouslama
DHDiogo C Haussen
Diogo C Haussen
JGJonathan A Grossberg
Jonathan A Grossberg
CBClara M Barreira
Clara M Barreira
IBImramsjah Martijn J van der Bom
Imramsjah Martijn J van der Bom
RNRaul G Nogueira
Raul G Nogueira
Bypassing the emergency department and the computed tomography suite by directly transporting to the neuroangiography suite for imaging assessment and treatment may shorten reperfusion times while maintaining proper patient selection. To determine whether flat-panel detector multiphase computed tomography angiography protocol is associated with reduced treatment times and a similar safety profile as the standard imaging protocol. Single-center prospective study of consecutive patients with anterior circulation large vessel occlusion strokes transferred to our facility for consideration of endovascular therapy from May 2016 to December 2017. Those with basilar strokes and/or presenting to the emergency department were excluded. Patients were categorized into two groups: (1) flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment group, with patients transferred directly to the suite for multiphase computed tomography angiography; and (2) patients undergoing standard protocol including computed tomography ± computed tomography angiography/CT perfusion. The groups were matched for age, baseline National Institute of Health Stroke Scale, and pretreatment glucose. Baseline characteristics, time metrics, and outcomes were compared. Out of 419 patients who underwent endovascular therapy over the study period, 210 patients fit inclusion criteria, with 54 (25.7%) in the flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment group. After matching, 49 flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment/control pairs were generated and analyzed. Baseline characteristics were well balanced. Flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment patients had significantly shorter median door-to-puncture (33 [26.5-47] vs. 55 [44.5–66] min, p < 0.001), door-to-reperfusion (85 [57.5–115.5] vs. 110 [80–153], p = 0.005) and picture-to-puncture (18 [13.5–22.5] vs. 42 [32–47.5] min, p < 0.001) times. There were no differences in rates of successful reperfusion (modified thrombolysis in cerebral infarction 2b-3, 95.9% vs. 100%, p = 0.5), parenchymal hematomas type-2 (4.1% vs. 2%, p = 1.00), good outcome (90-day modified Rankin Scale 0–2, 44.9% vs. 40.8%, p = 0.68), and 90-day mortality (14.3% vs. 22.4%, p = 0.30). Directly transferring patients to angiography and using multiphase computed tomography angiography to determine the eligibility for endovascular therapy is safe and may result in a significant reduction in treatment times. Future larger studies are warranted.

1 May 2021 in European Journal of Radiology
Verified
Journal Article
Open access
PNPatrick Nicholson
Patrick Nicholson
NCNicole M. Cancelliere
Nicole M. Cancelliere
JBJohn Bracken
John Bracken
EHErik Hummel
Erik Hummel
FNFred van Nijnatten
Fred van Nijnatten
VPVitor Mendes Pereira
Vitor Mendes Pereira
Cone beam CT (CBCT) imaging assessment of acute ischemic stroke (AIS) patients with large-vessel occlusion (LVO) in the angiosuite may improve stroke workflow and decrease time to recanalization. In order for this workflow to gain widespread acceptance, current CBCT imaging needs further development to improve image quality. Our study aimed to compare the image quality of a new CBCT protocol performed directly in the angiosuite with imaging from multidetector CT as a gold standard. AIS patients with an LVO who were candidates for endovascular treatment were prospectively included in this study. Following conventional multidetector CT (MDCT), patients underwent unenhanced cone beam CT (XperCT, Philips) imaging in the angiosuite, using two different protocols: a standard 20.8 s XperCT and/or an improved 10.4 s XperCT protocol. Images were evaluated using both qualitative and quantitative methods. We included 65 patients in the study. Patients received CBCT imaging prior to endovascular treatment; 18 patients were assessed with a standard 20.8 s protocol scans and 47 with a newer 10.4 s scan. The quantitative analysis showed that the mean contrast-to-noise ratio (CNR) was significantly higher for the newer 10.4 s protocol compared with the 20.8 s protocol (2.08 +/- 0.64 vs. 1.15 +/- 0.27, p < 0.004) and the mean image noise was significantly lower for the 10.4 s XperCTs when compared with the 20.8 s XperCTs (6.30 +/- 1.34 vs. 7.82 +/- 2.03, p=<0.003). Qualitative analysis, including 6 measures of image quality, demonstrated that 74.1 % of the 10.4 s XperCT scans were ranked as 'Acceptable' for assessing parenchymal imaging in AIS patients(scoring 3-5 points on a 5-point Likert-scale), compared with 32.4 % of the standard 20.8 s XperCT and 100 % of the MDCT scans. Compared to the MDCT studies, 83 % of the 10.4 s XperCT scans were deemed sufficient image quality for a direct-to-angiosuite selection, compared to only 11 % for the standard 20.8 s scans. The largest image quality improvements included grey/white matter differentiation (59 % improvement), and reduction of image noise and artefacts (63 % & 50 % improvement, respectively). Continued advances in cone-beam CT allow marked improvements in image quality for the assessment of brain parenchyma, which supports a direct-to-angiosuite approach for AIS patients eligible for thrombectomy treatment.

27 April 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
NCNicole Mariantonia Cancelliere
Nicole Mariantonia Cancelliere
EHEric Hummel
Eric Hummel
FNFred van Nijnatten
Fred van Nijnatten
PHPeter van de Haar
Peter van de Haar
PWPaul Withagen
Paul Withagen
VPVitor Mendes Pereira
Vitor Mendes Pereira
Background Cone-beam computed tomography (CBCT) imaging of the brain can be performed in the angiography suite to support various neurovascular procedures. Relying on CBCT brain imaging solely, however, still lacks full diagnostic confidence due to the inferior image quality compared with CT and various imaging artifacts that persist even with modern CBCT. Objective To perform a detailed evaluation of image artifact improvement using a new CBCT protocol which implements a novel dual-axis ‘butterfly’ trajectory. Methods Our study included 94 scans from 47 patients who received CBCT imaging for assessment of either ischemia or hemorrhage during a neurovascular procedure. Both a traditional uni-axis ‘circular’ and novel dual-axis ‘butterfly’ protocol were performed on each patient (same-patient control). Each brain scan was divided into six regions and scored out of 3 based on six artifacts originating from various physics-based and patient-based sources. Results The dual-axis trajectory produces CBCT images with significantly fewer image artifacts than the traditional circular scan (whole brain average artifact score, AS: 0.20 vs 0.33), with the greatest improvement in bone beam hardening (AS: 0.13 vs 0.78) and cone-beam artifacts (AS: 0.04 vs 0.55). Conclusions Recent developments in CBCT imaging protocols have significantly improved image artifacts, which has improved diagnostic confidence for stroke and supports a direct-to-angiography suite transfer approach for patients with acute ischemic stroke.

6 April 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JCJ.R. Cebral
J.R. Cebral
FMF. Mut
F. Mut
BCB.J. Chung
B.J. Chung
LSL. Spelle
L. Spelle
JMJ. Moret
J. Moret
DRDaniel Ruijters
Daniel Ruijters
BACKGROUND AND PURPOSE: Hemodynamics is thought to be an important factor for aneurysm progression and rupture. Our aim was to evaluate whether flow fields reconstructed from dynamic angiography data can be used to realistically represent the main flow structures in intracranial aneurysms. MATERIALS AND METHODS: DSA-based flow reconstructions, obtained during interventional treatment, were compared qualitatively with flow fields obtained from patient-specific computational fluid dynamics models and quantitatively with projections of the computational fluid dynamics fields (by computing a directional similarity of the vector fields) in 15 cerebral aneurysms. RESULTS: The average similarity between the DSA and the projected computational fluid dynamics flow fields was 78% in the parent artery, while it was only 30% in the aneurysm region. Qualitatively, both the DSA and projected computational fluid dynamics flow fields captured the location of the inflow jet, the main vortex structure, the intrasaccular flow split, and the main rotation direction in approximately 60% of the cases. CONCLUSIONS: Several factors affect the reconstruction of 2D flow fields from dynamic angiography sequences. The most important factors are the 3-dimensionality of the intrasaccular flow patterns and inflow jets, the alignment of the main vortex structure with the line of sight, the overlapping of surrounding vessels, and possibly frame rate undersampling. Flow visualization with DSA from >1 projection is required for understanding of the 3D intrasaccular flow patterns. Although these DSA-based flow quantification techniques do not capture swirling or secondary flows in the parent artery, they still provide a good representation of the mean axial flow and the corresponding flow rate.

23 December 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
NCNicole M Cancelliere
Nicole M Cancelliere
FNFred van Nijnatten
Fred van Nijnatten
EHEric Hummel
Eric Hummel
PWPaul Withagen
Paul Withagen
PHPeter van de Haar
Peter van de Haar
VPVitor M Pereira
Vitor M Pereira
Background Imaging assessment for acute ischemic stroke (AIS) patients in the angiosuite using cone beam CT (CBCT) has created increased interest since endovascular treatment became the first line therapy for proximal vessel occlusions. One of the main challenges of CBCT imaging in AIS patients is degraded image quality due to motion artifacts. This study aims to evaluate the prevalence of motion artifacts in CBCT stroke imaging and the effectiveness of a novel motion artifact correction algorithm for image quality improvement. Methods Patients presenting with acute stroke symptoms and considered for endovascular treatment were included in the study. CBCT scans were performed using the angiosuite X-ray system. All CBCT scans were post-processed using a motion artifact correction algorithm. Motion artifacts were scored before and after processing using a 4-point scale. Results We prospectively included 310 CBCT scans from acute stroke patients. 51% (n=159/310) of scans had motion artifacts, with 24% being moderate to severe. The post-processing algorithm improved motion artifacts in 91% of scans with motion (n=144/159), restoring clinical diagnostic capability in 34%. Overall, 76% of the scans were sufficient for clinical decision-making before correction, which improved to 93% (n=289/310) after post-processing with our algorithm. Conclusions Our results demonstrate that CBCT motion artifacts are significantly reduced using a novel post-processing algorithm, which improved brain CBCT image quality and diagnostic assessment for stroke. This is an important step on the road towards a direct-to-angio approach for endovascular thrombectomy (EVT) treatment.