Shiqi Hu

Shiqi Hu

Auto-generated profile, based on publicly available information

Shiqi Hu

Jinan University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SHShiqi Hu
Shiqi Hu
JCJiayao Chen
Jiayao Chen
JLJunhao Liang
Junhao Liang
JLJiajia Luo
Jiajia Luo
WSWeicheng Shi
Weicheng Shi
YLYunhan Luo
Yunhan Luo

20 October 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
SHShiqi Hu
Shiqi Hu
WSWeicheng Shi
Weicheng Shi
YCYu Chen
Yu Chen
YCYaofei Chen
Yaofei Chen
GLGui-Shi Liu
Gui-Shi Liu
ZCZhe Chen
Zhe Chen
Extremely high sensitivity is the long-time pursing goal for surface plasmon resonance (SPR) sensors, which means the capability to detect analytes with lower concentrations or interactions for smaller biomolecules. It was suggested that a flat dispersion for the plasmon material enables to enhance the sensitivity dramatically. However, the regulation ability of inherent dispersion in natural materials is limited. With the appearance of hyperbolic metamaterials (HMMs), the management of the plasmon materials dispersion becomes possible. In this paper, the HMMs with metal/dielectric multilayer structure are proposed to construct the SPR sensors. Through numerical simulations and theoretical analysis, we find that the flat dispersion in the HMM structure could significantly benefit the sensitivity improvement for HMM-SPR sensors. As a result, the proposed HMM-SPR sensor obtains an ultrahigh sensitivity of 34.00 μm/RIU in the experiment, which is one order higher in magnitude than that of the conventional monolayer metallic SPR sensors. Thus, this research shows insight into understanding the dependence of the HMM-SPR sensitivity on dispersion management and provides a practical methodology to develop extremely high-sensitivity SPR sensors based on artificial plasmon materials.

25 March 2025 in Measurement
Verified
Journal Article
Closed access
SHShiqi Hu
Shiqi Hu
CSChao Shen
Chao Shen
KCKaifeng Chen
Kaifeng Chen
YCYing Chen
Ying Chen
WXWei Xiao
Wei Xiao
YLYunhan Luo
Yunhan Luo

14 February 2022 in Advanced Science
Verified
Journal Article
Open access
PDF file
ZXZhaoyi Xu
Zhaoyi Xu
LWLingzhi Wang
Lingzhi Wang
XHXiao Huan
Xiao Huan
HLHeekwon Lee
Heekwon Lee
JYJihyuk Yang
Jihyuk Yang
JKJi Tae Kim
Ji Tae Kim
Nanodiamonds Diamond nanocrystals, namely nanodiamonds, hosting point defects such as nitrogen-vacancy (NV) centers have been emerging as one of the most promising quantum materials. In article numbe...

21 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
CYChu Yi
Chu Yi
JLJunhao Liang
Junhao Liang
JYJinming Yuan
Jinming Yuan
LZLingling Zhang
Lingling Zhang
TLTingting Liu
Tingting Liu
YLYunhan Luo
Yunhan Luo
Surface plasmon resonance (SPR) technology is pivotal for label-free biomolecular detection but suffers from low throughput, narrow dynamic range, and insufficient sensitivity, limiting its use in high-throughput scenarios like medical diagnosis and drug screening. To address these issues, we propose a polarization-controlled intensity-modulated SPR imaging (SPRi) system integrating a 12-channel microfluidic chip and CMOS imaging technology. Its core mechanism leverages the SPR-induced phase difference between s-polarized and p-polarized light: p-polarized light excites surface plasmons for an additional phase shift, while s-polarized light remains unaffected, producing elliptically polarized reflected light. By precisely adjusting optical components and using Jones matrix modeling, refractive index changes are converted into multi-level amplified signals of phase, polarization state, and light intensity. Experimental results show a refractive index sensitivity of 24,300 a.u./RIU (linear range: 1.337–1.370 RIU), a resolution of 9.96×10⁻⁷ RIU (dynamic range: 1.331–1.410 RIU), and a baseline drift of 0.63 RU/min. Real-time self-reference suppresses noise (RMS = 0.0242). Biomolecular experiments confirm a sensitivity of 0.06586 a.u.·mL/μg for mouse IgG and a detection limit of 1.56 pg/mL for D-biotin, offering a powerful platform for biomedicine, environmental monitoring, and drug research.

14 July 2026 in Analytical Chemistry
Verified
Journal Article
Closed access
CYChu Yi
Chu Yi
JLJunhao Liang
Junhao Liang
JYJinming Yuan
Jinming Yuan
LZLingling Zhang
Lingling Zhang
TLTingting Liu
Tingting Liu
YLYunhan Luo
Yunhan Luo