Geothermal Energy Piles (GEP) are an innovative renewable energy technology designed to access and exploit the relative constant temperature of the ground for efficient heating and cooling of buildings. In this paper, the design issues and operational considerations of GEPs are discussed, and their basic processes and mechanisms summarized. The controlling factors, such as the properties of the circulation fluid, flow rate, soil type and pile material are also discussed. A series of numerical analyses were performed to investigate the heat exchange behavior of GEPs for a variety of operational conditions. Based on these analyses, recommendations are drawn on practices which promote the most efficient GEP operation.
1 October 2014 in DFI Journal The Journal of the Deep Foundations Institute
This paper focuses on the main issues discussed during a session on the impact of thermohydromechanical behavior of soils on thermoactive geotechnical systems, and how they could affect the performance of thermoactive geotechnical systems. Both soil behavior as well as soil–structure interaction behavior was discussed. The main observation from the session was that the thermohydromechanical behavior of saturated soils has reached a mature understanding, with several established constitutive models that can be used by engineers. However, there are still opportunities to enhance these constitutive models by considering issues such as unsaturated conditions, anisotropic stress states, cyclic heating and cooling effects, and changes in the preconsolidation stress during heating and cooling. Further there are still opportunities to improve our understanding of soil/concrete interface behavior, including the development of novel testing approaches.
The installation of stone columns or piers in a loose, saturated sand deposit can potentially mitigate the risk of liquefaction by decreasing the seismic demand on the soil by redistributing the induced shear stresses from the sand to the columns or piers. In calculating the shear stress redistribution, it is commonly assumed that both the soil and the columns or piers respond as shear beams. Although less common, it has also been assumed that the soil responds as a shear beam and that the columns or piers respond as flexural beams, with the redistribution of the shear stresses computed accordingly. However, the results presented herein show that the columns or piers, and the soil immediately surrounding the column/pier, deform in a combination of shear and flexure. The percent contribution of shear versus flexural deformation of the column or pier varies with depth, with the column/pier deforming predominantly in flexure near the ground surface and predominantly in shear at depth. The percent contribution of each mode of deformation governs the redistribution of the shear stresses from the soil to the pier. The distribution of the shear stresses between the soil and columns or piers are quantified for "typical" properties of a loose, saturated sand profile reinforced with ImpactTM Rammed Aggregate PiersTM.
Heat exchange capacity of an Energy Pile is a key parameter in the design of these elements as ground sourced heat exchangers. In most cases, field thermal conductivity tests are necessary to verify design assumptions similar to running a conventional pile load test to prove pile capacity. Current standards for measuring the heat exchange performance of geothermal systems are limited and do not directly apply to Energy Piles. Most importantly, current guidelines limit the maximum diameter of a tested geothermal heat exchange element to 6 inches. We have developed a 3D numerical model to simulate thermal conductivity testing and calibrated the numerical model with a thermal conductivity field test. This model will allow us to perform a series of numerical analyses to test the validity of the assumptions underlying current thermal conductivity testing procedures.
Ground improvement using stiff columnar reinforcement, such as stone, jet-grout, and soil-mix columns, is commonly used for mitigation of seismic damage in weak ground. Seismic shear stress reduction in the reinforced soil mass is often counted on for reducing liquefaction potential. Current design methods assume composite behavior of the reinforced soil, where the shear stress reduction is based on the ratio of the columnar stiffness relative to the soil as well as the area, replacement ratio. This implicitly assumes the stiff columns will deform in pure shear along with the soil. We performed 3-D dynamic finite element modeling to better understand the column deformation and shear stress reduction behavior. We found that the columns deform in both shear and flexure, providing little seismic shear stress reduction and current methods may be unconservative.
Ground-source heating of bridge decks can be an alternative to the use of salts and chemicals to deice bridge decks. Energy foundations, geothermal boreholes, shallow trenches, or the approach embankment can be utilized as energy storage media and heat exchange pathways to utilize the ground as a heat source. Coupling the energy foundation with a ground-source heat pump can provide higher inlet fluid temperatures and result in more effective bridge heating but at the expense of greater energy consumption and increased system complication. Circulating the fluid directly from the energy foundation to the bridge deck relies heavily on the in situ ground temperatures. This paper outlines the operational principles and how these are related to the design parameters of bridge-deck deicing systems. A series of parametric analyses was performed to investigate the bridge-deck heating process. The analyses considered a variety of tube spacings, inlet fluid temperatures (i.e., ground temperatures), flow rates, wind speeds, ambient temperatures, and thicknesses of concrete cover over the circulation tubes. The results serve as a benchmark to gauge the operational conditions and the energy requirements for designing ground-source bridge deck deicing systems. Ground temperatures serve as a baseline for heating of bridge decks with passive heating in the winter, and this study underlines its limitations at colder environments. This can be overcome by collecting heat from the bridge deck in the summer and injecting the collected heat into the ground to raise the ground temperatures. This stored energy can be reclaimed in the winter when needed. The issues related to heat collection and ground storage are part of a broader study and fall outside the scope of this paper.