Shuma Adhikari

Shuma Adhikari

Auto-generated profile, based on publicly available information

Shuma Adhikari

NIT Manipur,Department of Electrical Engineering,Imphal,Manipur,India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2016 in SpringerPlus
Verified
Journal Article
Open access
PDF file
SAShuma Adhikari
Shuma Adhikari
NSNidul Sinha
Nidul Sinha
TDThingam Dorendrajit
Thingam Dorendrajit
This study presents fuzzy logic based online fault detection and classification of transmission line using Programmable Automation and Control technology based National Instrument Compact Reconfigurable i/o (CRIO) devices. The LabVIEW software combined with CRIO can perform real time data acquisition of transmission line. When fault occurs in the system current waveforms are distorted due to transients and their pattern changes according to the type of fault in the system. The three phase alternating current, zero sequence and positive sequence current data generated by LabVIEW through CRIO-9067 are processed directly for relaying. The result shows that proposed technique is capable of right tripping action and classification of type of fault at high speed therefore can be employed in practical application.

1 July 2019
Verified
Conference Paper
Closed access
Subir DattaSubir Datta
Subir Datta
AIAkibul Islam
Akibul Islam
TSTridip Saikia
Tridip Saikia
SAShuma Adhikari
Shuma Adhikari
The performance of a grid connected permanent magnet synchronous generator (PMSG) based wind turbine mT) system under varying wind velocity is studied in this paper. To achieve variable speed and constant frequency operation, two vector control schemes are adopted for controlling both the converters. Field oriented based vector control scheme is used to control Machine Side Converter (MSC) and grid oriented based vector control scheme is used to control Grid Side Converter (GS C). Maximum Power Point Tracker (MPPT) is also playing a very important role to extract maximum power from wind and hence, perturb and observe (P & O) algorithm is used. Simulation of the complete system is done in MATLAB/Simulink platform and time domain results are taken under varying wind velocity and analyzed those results in details.

20 September 2019 in International Journal of Emerging Electric Power Systems
Verified
Journal Article
Closed access
PDF file
BKBadal Kumar
Badal Kumar
SAShuma Adhikari
Shuma Adhikari
Subir DattaSubir Datta
Subir Datta
NSNidul Sinha
Nidul Sinha
The paper presents a real time modelling of self-reliant isolated grid comprising both governable and ungovernable sources. The frequency of this system must be maintained to its desired value by reducing its deviation occurred when there is a mismatch between the load demand and the actual power generation. In order to achieve it, the actual power output of the micro-grid is required to regulate. Therefore, an attempt is made in this paper to design a modified bias (MB) with LDR (load disturbance rejection) based PID (proportional integral derivative) Controller and it can also be called droop based controller (DBC). Simulation of the micro-grid system with proposed MB-LDR based control scheme is successfully done in Real Time Simulation platform using the digital simulator of OPAL-RT OP4510. Simulation results of the system for different conditions are presented and analysis is given in details. Thereafter, comparative performance of the results obtained using proposed MB-LDR based controller with that of LDR and classical controllers is made. Results show that the proposed MB-LDR based controller gives better response as compare to other two methods in terms of peak transient deviation, settling time and number of oscillations.

1 July 2019
Verified
Conference Paper
Closed access
Subir DattaSubir Datta
Subir Datta
AIAkibul Islam
Akibul Islam
TSTridip Saikia
Tridip Saikia
SAShuma Adhikari
Shuma Adhikari
BAPPA ROYBAPPA ROY
BAPPA ROY
In this paper, the performance of a Unified Power Quality Conditioner (UPQC) is studied under nonlinear and unbalanced linear loads and also during symmetrical and asymmetrical faults. Two control schemes are used to regulate the UPQC. One of the control schemes are used for injecting/absorbing the requited amount of voltage into/from the line to maintain rated voltage during voltage sag/swell conditions whereas other is used for injecting current into the line to reduce harmonics during non-linear loads. Simulation is done using MATLAB/Simulink software and simulink results are analyzed.

3 March 2020
Verified
Book Chapter
Closed access
PDF file
BKBadal Kumar
Badal Kumar
GKGanesh Ketha
Ganesh Ketha
LSLoitongbam Surajkumar Singh
Loitongbam Surajkumar Singh
SAShuma Adhikari
Shuma Adhikari
NSNidul Sinha
Nidul Sinha