We prepared a series of pressed powder tablets and chalcopyrite glass standards to correct mass bias when using standard–sample bracketing for in situ sulfur isotope measurements. A femtosecond laser ablation coupled multi-collector inductively coupled plasma mass spectrometry (fsLA-MC-ICP-MS) method was used to determine the sulfur isotope composition of these standards. Chalcopyrite glass (YN411-m) was prepared by quickly quenching the fused chalcopyrite, which was melted at 1000 °C under a protective N2 atmosphere. Multiple experiments were conducted for homogeneity testing of YN411-m by fsLA-MC-ICP-MS and the external precision was 0.28‰ (n = 35). Mineral particles, pressed powder tablets, and chalcopyrite glass were used as bracketing standards when determining the δ34S of a natural chalcopyrite (GC). The results showed that the concentration, elemental composition, and crystal structure caused the matrix effect. Considering practicability, the melted glass was a more appropriate standard than the pressed powder tablet. We also found that the carrier gas flow rate, laser fluence, and spot size impacted the regularity of results. Therefore, we can obtain accurate δ34S by adjusting the laser and MC-ICP-MS parameters when using non-matrix matching standards. Furthermore, fsLA-MC-ICP-MS is advantageous for in situ sulfur isotope measurement because the sensitivity can be improved and it dramatically improves the spatial resolution (10–20 μm), which can be used to explain the origin of multi-genesis deposits by analyzing smaller mineral micro-areas, especially mineral fracture-filling sulfides later in mineralization.
1 December 2015 in Journal of Analytical Atomic Spectrometry
A new glass-making method was developed to allow the in situ analysis of trace elements and lead isotopes in rock samples. The apparatus used to prepare homogeneous glass samples from silicate rock powder consisted of a small (450 mm3) boron nitride vessel and a high-temperature furnace. The concentrations of trace elements were measured by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and lead isotopic compositions were measured by femtosecond laser ablation multicollector inductively coupled plasma mass spectrometry (fsLA-MC-ICP-MS). The method was evaluated by analyzing glass disks fused from six geochemical reference materials (spanning the compositional range basalt–andesite–rhyolite). The measured 34 trace element contents match the reference values within 15%, and the mean Pb isotopic ratios measured by fsLA-MC-ICP-MS agree with those obtained by solution nebulizer MC-ICP-MS within 2s uncertainty intervals. By using seven Faraday cups operating in static mode we were able to obtain 207Pb/206Pb and 208Pb/206Pb results with improved precisions by a factor of 2–3 compared to those obtained by previous single-collector sector-field ICPMS and LA-MC-ICP-MS. The accuracies of 207Pb/206Pb and 208Pb/206Pb values obtained by fsLA-MC-ICP-MS lie between −0.073% and +0.023%, which are well determined for geological research. Measured 208Pb/204Pb, 207Pb/204Pb and 206Pb/204Pb isotope ratios for the USGS reference RGM-2 (20 μg g−1 total Pb) and BCR-2 (11 μg g−1 total Pb) agree within 0.029% and 0.055% respectively of the preferred values. For GSR-3 (4.27 μg g−1 total Pb), the accuracies of the 208Pb/204Pb, 207Pb/204Pb and 206Pb/204Pb ratios obtained by fsLA-MC-ICP-MS lie between −0.064% and −0.004% with the accepted external precision of <0.15% (1RSD), which are better than previous LA-MC-ICP-MS data in terms of quantification limits. We also provide precise Pb isotopic data for the reference materials GSR-2, GSR-3, QLO-1, and RGM-2 obtained by solution nebulizer MC-ICP-MS. Our method is simpler, cheaper and faster to determine trace elements and Pb isotopic ratios in geological samples, while retaining similar levels of accuracy and precision.
9 September 2016 in Journal of Analytical Atomic Spectrometry
In this study, we present a new method for the dissolution of silicate rocks by flux-free fusion using a boron nitride vessel in preparation for analysis of bulk rock trace elements; this method is especially applicable to felsic intrusive rocks. The method was evaluated by analyzing five intrusive rocks (GSP-2, GSP-1, G-2, GSR-1 and QLO-1) and five extrusive rocks (AGV-2, BCR-2, BHVO-2, GSR-3 and RGM-2). The optimum conditions for the fusion of intrusive rocks were determined to be heating at 1600 °C for 1 min, which is effective to break up strong Si–O bonds. The fused glasses were dissolved using HF/HNO3 acids in closed screw-top Savillex vials on a hotplate; no high-pressure PTFE digestion bomb was required. Zr and Hf were completely recovered from the granodiorite GSP-2 reference material in 6 hours at 150 °C, which was 8 times faster than the method using a conventional high-pressure PTFE digestion bomb at 190 °C. The precision (RSD%, 1 s) of the elemental determinations in nearly 92% of the analyzed samples was better than 4%. Replicate analyses (n = 3) of the reference materials indicated that most of the results agreed with the reference values within a relative error of <10%. Additionally, the flux-free fusion retained all the materials in solution and was valid for volatile elements.
18 September 2023 in Journal of Analytical Atomic Spectrometry
This study compares three zircon synthesis techniques (synthesis, high-temperature and high-pressure sintering and fast hot-pressing sintering) for the preparation of reference materials for Hf isotope analysis of zircon by laser ablation multi-collector inductively-coupled plasma mass spectrometry (LA-MC-ICP-MS). Ultrafine milled zircon powder particles doped with Yb2O3 produced by wet milling were used to synthesize zircon samples by using high-temperature and high-pressure sintering and fast hot-pressing sintering techniques. Li–Mo flux was necessary to obtain synthetic zircon grains. Zr signals for synthetic zircon grains and high-temperature and high-pressure sintered zircon are consistent with those of natural zircons but higher than that of fast hot-pressing sintered zircon, indicating that high-temperature and high-pressure sintered zircon has approximated the theoretical maximum density due to high pressure. The Hf isotopic compositions of high-temperature and high-pressure sintered and fast hot-pressing sintered zircon are comparable to those of the initial starting materials, whereas the Hf isotopes in synthetic zircon grains deviate slightly from those of the initial Hf solution. Compared with Hf isotope ratios obtained by SN-MC-ICP-MS, all preparation techniques give reliable LA-MC-ICP-MS results, suggesting that all synthetic zircon samples have great potential as both tools for in situ method development and isotopic reference materials.
11 January 2021 in Geostandards and Geoanalytical Research
Here we present an analytical method for Fe isotopic measurements in low resolution mode, using a Nu Sapphire collision cell-equipped multi-collector inductively coupled plasma mass spectrometer by standard-sample bracketing. High Fe sensitivity was obtained through reducing Ar based interference by over 9 orders of magnitude whilst other analytes remained unaffected. The effects of Fe concentration, Fe beam intensity and HNO3 molarity mismatch between the standard and sample and the presence of matrix elements have been evaluated. The long-term analyses of JMC Fe and BCR-2 indicate that the obtained isotopic ratios are highly reproducible, with precisions of better than ±0.03‰ for δ56Fe (2SD). Such accurate and precise data could be acquired via 3 to 6 repeat measurements consuming 50–100 ng Fe, which has improved by a factor 40 compared to those previously reported on other instruments. Accurate measurements were achieved by closely matching Fe intensities between the sample and standard (a 5% mismatch would create a 0.02‰ offset in the 56Fe/54Fe ratio). On the other hand, the ratio of the concentration between the matrix elements and Fe, such as CNa/CFe, CMg/CFe, CCa/CFe, CTi/CFe and CNi/CFe, should be kept under 0.1, CK/CFe under 0.3, CAl/CFe and CCu/CFe under 1, and CCo/CFe and CZn/CFe under 2 to avoid any matrix effect. In addition, high precision Fe isotopic data were obtained on twenty-one geological reference materials and were highly consistent with the literature values. Furthermore, we obtained δ56Fe of standard chalcopyrite (XTC) for the first time: 0.127 ± 0.027‰ (2SD, n = 3).